Search results for: Piezoelectric Sensor
-
Development of beltless respiration and heartbeat sensor based on flexible piezoelectric film
PublicationThe main goal of this work is to report initial development on a respiration and heartbeat measurement sensor that can be used in continuous monitoring conditions at a minimal impact on the patient. General description of the sensor, consisting of a PVDF film and the bonding layer, is given. Open-circuit voltage generated by the sensor is estimated by analytical and numerical calculations. Analog and digital interface used to extract...
-
Design and simulation of a new prototype of piezoelectric cantilever sensor/actuator for analysis of the soft tissues properties
PublicationThis paper is devoted to a new prototype of piezoelectric cantilever transducer dedicated for the characterization of the mechanical properties of soft tissues. General description of the actuator’s structure is presented including the basic principles of the measurement. The chosen geometry of the prototype is discussed and compared with the existing one. Constitutive equations are presented for the active and passive layer of...
-
Identification of the mechanical properties of the skin by electromechanical impedance analysis of resonant piezoelectric actuator
PublicationThis paper is devoted to the analysis and verification of developed piezoelectric sensor/actuator for measuring the mechanical properties of soft tissues, especially human skin. The key element of the measurement structure is an electromechanical system that uses both the reverse piezoelectric effect (vibration generation – stimulation of the tissues in the appropriate frequency range) and direct piezoelectric effect (system response...
-
Data from pizoelectric pressure sensor placed inside PWK pump chamber
Open Research DataThe dataset contains raw data acquired from a piezoelectric pressure sensor placed inside PWK pump chamber. Pumping pressure was 10MPa, displacement was set to 100%, oil temperature was 33C. Columns "Czas" stand for a time in seconds and milliseconds, "Napięcie" stands for Voltage in Volts
-
Koncepcja i analiza sensora/aktuatora piezoelektrycznego do pomiaru procesu starzenia się ludzkiej skóry
PublicationNiniejszy artykuł przedstawia nową koncepcję piezoelektrycznego sensora/aktuatora przeznaczonego do pomiaru właściwości mechanicznych tkanek miękkich a w szczególności skóry ludzkiej. Wyjaśnione jest analityczne podejście z wykorzystaniem schematu zastępczego Mason’a określającego aktuator w stanie rezonansu oraz opis metody impedancji elektromechanicznej wykorzystanej w systemie pomiarowym. Analiza z użyciem metody elementów...
-
Piezoelectric Transducer for Mechanical Assessment of Soft Tissues. Concept, Implementation and Analysis
PublicationThe main goal of this work was following: preparation of a new concept, implementation and analysis of the piezoelectric resonant sensor/actuator for measuring the aging process of human skin. The research work has been carried out in the framework of cooperation between the INP-ENSEEIHT-LAPLACE, Toulouse, France, and at the Gdansk University of Technology, Faculty of Electrical and Control Engineering, Research Group of...
-
Determination of long-chain aldehydes using a novel quartz crystal microbalance sensor based on a biomimetic peptide
PublicationThere is an increasingly popular trend aimed at improvement of fundamental metrological parameters of sensors via implementation of materials mimicking biological olfactory systems. This study presents investigation on usefulness of the peptide mimicking HarmOBP7 region as a receptor element of the piezoelectric sensor for selective analysis of long-chain aldehydes. Identification of odorant binding proteins creates new possibilities...
-
Damage detection in plates based on Lamb wavefront shape reconstruction
PublicationMany of the current studies in the area of damage detection using elastic wave propagation are based on deploying sensor networks with a large number of piezoelectric transducers to detect small-size cracks. A major limitation of these studies is that cracks are usually larger and have different shapes in real cases. Moreover, using a large number of sensing nodes for damage detection is both costly and computationally intensive....
-
On nonlinear 3D electro-elastic numerical modeling of two-phase inhomogeneous FG piezocomposites reinforced with GNPs
PublicationThe novelty here comes from not only the perfect nonlinear three-dimensional (3D) electro-elasticity investigation but also the mixed material itself. The literature widely showed mechanical assessments on the piezoelectric structures; however, a lack of nonlinear three-dimensional elasticity studies has been witnessed on these kinds of smart materials. Therefore, a nonlinear 3D elasticity-piezoelectricity coupling is considered...
-
Acoustic emission studies of the 7075 aluminium alloy pitting corrosion process
Open Research DataThe dataset contains the cyclic polarization studies and corresponding acoustic emission measurements, revealing the pitting corrosion process of the passive layer at the surface of the 7075 aluminum alloy in the borate buffer with different chloride ions concentrations, in the range between 0.05 and 25 mM.
-
Investigation of Weigh-in-Motion Measurement Accuracy on the Basis of Steering Axle Load Spectra
PublicationWeigh-in-motion systems are installed in pavements or on bridges to identify and reduce the number of overloaded vehicles and minimise their adverse eect on road infrastructure. Moreover, the collected trac data are used to obtain axle load characteristics, which are very useful in road infrastructure design. Practical application of data from weigh-in-motion has become more common recently, which calls for adequate attention to...
-
A Highly Selective Biosensor Based on Peptide Directly Derived from the HarmOBP7 Aldehyde Binding Site
PublicationThis paper presents the results of research on determining the optimal length of a peptide chain to eectively bind octanal molecules. Peptides that map the aldehyde binding site in HarmOBP7 were immobilized on piezoelectric transducers. Based on computational studies, four Odorant Binding Protein-derived Peptides (OBPPs) with dierent sequences were selected. Molecular modelling results of ligand docking with selected peptides were...
-
Evaluation of Three Peptide Immobilization Techniques on a QCM Surface Related to Acetaldehyde Responses in the Gas Phase
PublicationThe quartz-crystal microbalance is a sensitive and universal tool for measuring concentrations of various gases in the air. Biochemical functionalization of the QCM electrode allows a label-free detection of specific molecular interactions with high sensitivity and specificity. In addition, it enables a real-time determination of its kinetic rates and affinity constants. This makes QCM a versatile bioanalytical screening tool for...
-
Impact of accuracy of weigh-in-motion data for pavement analysis and design: influence of temperature variations
PublicationThis paper investigates the effect of temperature on WIM-collected data using the steering axle load spectrum (SALS) and two datasets. The first dataset, provided by the WIM system operator, contains detailed raw data, while the second, supplied by the road authority, includes less detailed information but covers 46 stations with various sensor types and configurations: single-line bending plates and two-line quartz piezoelectric...
-
Data Compression in Ultrasonic Network Communication via Sparse Signal Processing
PublicationThis document presents the approach of using compressed sensing in signal encoding and information transferring within a guided wave sensor network, comprised of specially designed frequency steerable acoustic transducers (FSATs). Wave propagation in a damaged plate was simulated using commercial FEM-based software COMSOL. Guided waves were excited by means of FSATs, characterized by the special shape of its electrodes, and modeled...
-
Ultrasonic wave propagation and digital image correlation measurements of steel bars under 3-point bending
Open Research DataThe DataSet contains the results of the mechanical behaviour of a bar under a 3-point bending test. The bar was made of steel and had a cross-section of 5.96 × 5.96 mm2 and a length of 200 mm. The three-point bending test was performed using a Zwick/Roell Z10 universal testing machine (UTM), with a distance between supports of 12 cm. The parameters...