Search results for: doubly fed induction generator (dfig)
-
State Observer for Doubly-fed Induction Generator
PublicationIn the paper a new state observer for doubly-fed generator has been proposed. In the new approach an extended mathematical model of the doubly fed generator is used to form equations of the introduced z type observer. Stability of the observer has been verified through poles placement analyses. The active and reactive powers of the generator are controlled by a nonlinear multiscalar control method. Simulation and experimental results...
-
A Novel Speed Observer for Doubly-Fed Induction Generator
PublicationThe purpose of this paper is to show a new state observer for doubly-fed generator. A proposed z-type observer algorithm based on mathematical model of doubly fed generator with additional variables treated as a disturbances has been used. A nonlinear multiscalar control method has been used to control active and reactive power of the generator. All analyses were verified by simulations and experiments tests.
-
Cascaded doubly fed induction generator using PFC rectifiers
Publication -
Development and performance analysis of a novel multiphase doubly-fed induction generator
PublicationThis paper presents the research into the design and performance analysis of a novel five-phase doubly-fed induction generator (DFIG). The designed DFIG is developed based on standard induction motor components and equipped with a five-phase rotor winding supplied from the five-phase inverter. This approach allows the machine to be both efficient and reliable due to the ability of the five-phase rotor winding to operate during...
-
Non-Adaptive Speed and Position Observer of Doubly-Fed Induction Generator
PublicationThe non-adaptive speed and position estimation of a doubly-fed induction generator (DFIG) is presented in this paper. The speed observer is based on the mathematical model of DFIG and to stabilize the structure the Lyapunov method is used. The classic stator field-oriented control to active and reactive power control is used in the sensorless control system. The performance of the proposed algorithm of a speed observer is validated...
-
Voltage Control of a Stand-Alone Multiphase Doubly Fed Induction Generator
PublicationThis article presents a multiphase doubly fed induction generator (MDFIG) with a dedicated and unique control algorithm in a stand-alone wind energy conversion system. The algorithm has been developed and elaborated in the case of different emergency modes. Compared with the traditional double-fed induction generator, the MDFIG has increased reliability, reduced current level per phase, and low rotor harmonic currents. The control...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublicationThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
Design advantages and analysis of a novel five-phase doubly-fed induction generator
PublicationPurpose – The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approach – This paper presents the results of a research work related to fivephase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based...
-
Real-time hybrid model of a wind turbine with doubly fed induction generator
PublicationIn recent years renewable sources have been dominating power system. The share of wind power in energy production increases year by year, which meets the need to protect the environment. Possibility of conducting, not only computer simulation, but also laboratory studies of wind turbine operation and impact on the power system and other power devices in laboratory conditions would be very useful. This article presents a method...
-
Steady State Analysis of Twin Stator Cascaded Doubly Fed Induction Generator
Publication -
Sensorless Rotor Position Estimation of Doubly-Fed Induction Generator Based on Backstepping Technique
PublicationThis paper proposes a speed observer algorithm for the sensorless control of a doubly-fed induction generator based on classical adaptive backstepping technique. The sensorless control is shown using classic stator field oriented control which is used to active and reactive power control. Performance of the proposed algorithm of a speed observer is validated by simulation and experimental results obtained using a small-rating generator...
-
Cascaded doubly fed induction generator for mini and micro power plants connected to grid
Publication -
Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter
PublicationThe control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...
-
Non-Adaptive Speed and Position Estimation of Doubly-Fed Induction Generator in Grid-Connected Operations
PublicationThe nonadaptive speed and position estimation scheme for a doubly-fed induction generator (DFIG) is presented in this article. The observer structure is based on the extension of the mathematical model of DFIG to the introduced H vector. Based on the defined H vector, the nonadaptive position and speed estimation is proposed. The Lyapunov method is extended to the practical stability theorem to stabilize the structure. The classic...
-
Power control system structure of doubly‐fed induction generator connected to current source converter
PublicationThe power control system structures for a doubly-fed generator (DFIG) are proposed. The classical field oriented control and the feedback control with the multi-scalar variables were considered. The generator is working in the AC grid connection mode. The rotor side of the generator is connected to the current source converter (CSC); the stator is directly related to the AC grid. The static feedback linearization using the multi-scalar...
-
Winding function approach based design of novel five-phase brushless doubly fed induction generator
PublicationThe paper presents the concept of the new design of the five-phase brushless doubly fed induction generator. The generator is dedicated to the modern wind turbine. The innovative design approach uses a five-phase power supply from the stator control winding side of the generator with a stator three-phase classic power winding. The research results presented indicate that the electromagnetic coupling between the control and power...
-
Modelling and Control of a Brushless Multiphase Doubly-Fed Induction Generator in a Stand-Alone Wind Generation System
PublicationThe development of the novel multiphase brushless doubly-fed generator system and voltage controller for stand-alone mode configuration is proposed in this paper. The generator system is based on the new machine construction with multiphase control winding and traditional three-phase power winding. The dynamic model of multiphase brushless doubly-fed generator is presented, and the control strategy for voltage amplitude and frequency...
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter
PublicationNowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...
-
Control of the wind turbine generator
PublicationWind power system consists of two main parts: wind turbine and electrical generator. Wind turbine converts the energy of the flowing air into mechanical energy, next generator converts this energy into electrical energy that is sent to the power system. These two processes should be realized with maximum efficiency and the following requirements for the control system can be formulated: opti-mal wind power conversion, compensation...
-
Research of Emergency Modes of Wind Power Plants Using Computer Simulation
PublicationThe aim of this study is to investigate changes in the wind power plant energy production parameters under the conditions of sudden wind changes and voltage drop. To achieve these goals, a simulation of operation of wind power plants was performed. Twelve wind turbines with variable rotational speed equipped with a Fuhrländer FL 2500/104 asynchronous double-fed induction generator (DFIG) were used, each with an installed capacity...
-
Non-linear circuit model of a single doubly-fed induction machine formulated in natural axes for drive systems simulation purposes
PublicationMathematical modelling and a circuit model formulated in natural axes of a single doubly-fed induction machine, with the account of magnetic circuit nonlinearity are presented in the paper. Derivation of the model differential equations was based on Lagrange's energy method. State functions of magnetic elements in the model are non-linear and depend on all currents flowing in the machine windings and on the angle of rotor position....
-
Advances in CSI-fed induction motor drives
PublicationThe application of current source inverters (CSI)in induction motor (IM) drives offers a number of advantages,including: voltage boosting capability, natural shoot-throughshort-circuit protection and generation of sinusoidal voltages.The exact generation of sinusoidal voltages is possible thanks tothanks to the effect of the output ac filter capacitors and mayimprove the accuracy of sensorless IM control. The eliminationof high...
-
Application of wireless communication to small WECS with induction generator
PublicationWind energy conversion systems (WECS) seem to be self-evident elements of the future smart grids. Among many generator types the squirrel cage induction generator (SCIG) characterizes robustness and low cost. A full-scale power converter can perform smooth grid connection over wide speed range of multiple-stage geared SCIG. Increasing number of sensors can improve the WECS control and diagnostics but increasing number of thin wires...
-
Noninvasive method for rotor fault diagnosis in inverter fed induction motor drive
PublicationThis article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Double Fed Induction Machine Drives
PublicationContents of the Chapter 22:Machine model.Properties of the DFM.Steady state machine operation.Control rules and decoupled control.Decoupling based on MM machine model.Decoupling based on vector model.Decoupling based on rotor current equation.Overall control system.Control system based on MM model.Control system based on vector model.Estimation of variables.Calculation of the angle between stator and rotor.Remarks about digital...
-
Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation
PublicationIn this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...
-
The time-varying low-frequency magnetic-field emitted from the ship’s inverter-fed induction motor
Open Research DataThe dataset contains the magnetic field measurement results that are part of a comprehensive study on the assessment of the magnetic field emissions onboard of the research-training vessel. The measurements were carried out, nearby the bow thruster motor fed from the inverter, during maneuvering and the sea voyage. The bow thruster is assembled in the...
-
Over-Voltage Studies in Inverter Fed Induction Motor Drives
PublicationW pracy przedstawiono metodę identyfikacji pojemności pasożytniczych uzwojeń silników asynchronicznych uwzględniającą ich rozłożony charakter. Przedstawiony szerokopasmowy model obwodowy uzwojeń silnika asynchronicznego pozwala na modelowanie zjawisk przepięciowych w silnikach asynchronicznych, w szczególności zasilanych poprzez przekształtniki energoelektroniczne. Zaproponowana metoda analizy umożliwia również określanie składowych...
-
Autonomous Energy Matching Control in an LLC Induction Heating Generator
Publication -
Dual-Frequency Induction Heating Generator With Adjustable Impedance Matching
Publication -
Bearing current path and pulse rate in PWM-inverter-fed induction
Publication -
Control Systems of an Induction and Synchronous Motor Supplied by Current Source Converter Working as Generator
Publication -
Susceptibility of the LLC Resonance Generator for Induction Heating on Changes in Load Parameters Caused by Heating the Charge
Publication -
Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator
PublicationDue to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...
-
Jarosław Guziński prof. dr hab. inż.
PeopleJaroslaw Guzinski received M.Sc., Ph.D. and D.Sc. degrees from the Electrical Engineering Department at Technical University of Gdansk, Poland in 1994, 2000 and 2011 respectively. Since 2016 he is Associate Professor at Gdansk University of Technology. Currently he is the head of the Department of Electric Drives and Energy Conversion. From 2006 to 2009 he was involved in European Commission Project PREMAID Marie Curie, ‘Predictive...
-
Multiscalar Model Based Control Systems for AC Machines
PublicationContents of the Chapter: Nonlinear transformations and feedback linearization. Models of the squirrel cage induction machine: Vector model of the squirrel cage induction machine. Multiscalar models of the squirrel cage induction machine.Feedback linearization of multiscalar models of the induction motor.Models of the double fed induction machine: Vector model of the double fed induction machine. Multiscalar model of the...
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublicationThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
The multiscalar control of induction motor with the sliding mode controllers
PublicationThe control structure of induction motor is proposed in this paper. The structure of multiscalar control with conventional PI - controllers is well known in literature. The sliding mode multiscalar control (SMMC) conception is presented in this paper. The induction motor is fed by voltage source inverter. Comparison between two multiscalar control method is showed.
-
Induction machine behavioral modeling for prediction of EMI propagation.
PublicationThis paper presents the results of wideband behavioral modeling of an induction machine (IM). The proposed solution enables modeling the IM differential- and common-mode impedance for a frequency range from 1 kHz to 10 MHz. Methods of parameter extraction are derived from the measured IM impedances. The developed models of 1.5 kW and 7.5 kW induction machines are designed using the Saber Sketch scheme editor and simulated in the...
-
Przekształtnik prądu jako sterownik w układach napędowych z silnikami indukcyjnymi
PublicationThe circuits used for power conversion applied in drives with electric machines are classified into two groups: voltage source inverters (VSI) and current source inverters (CSI). Application of the current source inverter results in better properties of drive than application of voltage source inverter because there is no output filter. The development of power electronics and especially the IGBTs, in which on/off-times are very...
-
Audible noise in ship’s electrical drive systems with frequency converters
Open Research DataThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
Power Hardware-In-the-Loop Approach for Autonomous Power Generation System Analysis
PublicationThe article presents the Power Hardware-In-the-Loop (PHIL) dynamic model of a synchronous generator of 125 kVA for autonomous power generation system analysis. This type of system is typically composed of electrical energy sources in the form of several diesel generator units with synchronous machines, the main distribution switchboard and different loads. In modern power distribution systems, the proposed power management strategies...
-
Multiscalar Control Based Airgap Flux Optimization of Induction Motor for Loss Minimization
PublicationBased on the induction motor model, considering the core loss resistance that accounts for magnetic characteristic saturation, a speed control approach is devised with an adaptive full-order (AFO) speed observer. The induction motor model analysis is done sincerely in a stationary reference frame. The control approach incorporates a flux reference generator designed to meet optimal operational circumstances and a nonlinear speed...
-
Accurate modeling of quasi-resonant inverter fed IM drive
PublicationIn this paper wide-band modeling methodology of a parallel quasi-resonant dc link inverter (PQRDCLI) fed induction machine (IM) is presented. The modeling objective is early-design stage prediction of conductive electromagnetic interference (EMI) emissions of the considered converter fed IM drive system. Operation principles of the selected topology of PQRDCLI feeding IM drive are given. Modeling of the converter drive system is...
-
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
PublicationIn this paper the predictive estimation based control strategy for a quasi-resonant dc link inverter (PQRDCLI) is developed. Instead of direct measurement of dc link input inverter current – its estimation with one step prediction is applied. The PQRDCLI fed induction motor, controlled with a predictive current estimation stabilized inverter output voltage slopes independently of load. Moreover, reduction of overvoltage spikes...
-
A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.
PublicationIn this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...
-
Sensorless Disturbance Detection for Five Phase Induction Motor with Third Harmonic Injection
PublicationThe paper presents a sensorless disturbance detection procedure that was done on a five phase induction motor with third harmonic injection. A test bench was developed where a three phase machine serves as disturbance generator of different frequencies. The control of the machines is based on multi scalar variables that ensures an independent control of the motor EMF and the rotor flux. For disturbance identification a speed observer...
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublicationIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...