Search results for: TOLUEN
-
Application of linear buckling sensitivity analysis to economic design of cylindrical steel silos composed of corrugated sheets and columns
PublicationThe paper deals with global stability of steel cylindrical silos composed of corrugated walls and vertical columns with loads imposed by a bulk solid following Eurocode 1. The optimum silo design with respect to the steel weight was based on a sensitivity analysis method. The changes of silo column profiles at each design step were performed by means of influence lines for the buckling load factor due to the unit column bending...
-
Surface EMG-based signal acquisition for decoding hand movements
Open Research DataBiosignal processing plays a crucial role in modern hand prosthetics. The challenge is to restore functionality of a lost limb based on the signals acquired from the surface of the stump. The number of sensors (emg channels) used for signal acquisition influence the quality of a prosthetic hand. Modern algorithms (including neural networks) can significantly...
-
Effect of initial imperfection on buckling of thin-walled I columns
PublicationEffects of initial geometrical imperfections on critical buckling loads of thin-walled I columns are investigated. Torsional and flexural buckling are taken into account. The column behaviour is described in accord to the theory of thin-walled beams with nondeformable cross-section. Some numerical examples and conclusions related to effects of imperfections on properties of the critical loads are presented.
-
Influence of the Shear Cap Size and Stiffness on the Distribution of Shear Forces in Flat Slabs
PublicationThe scope of this paper is to investigate analytically and numerically the influence of shear cap size and stiffness on the distribution of shear forces in flat slabs in a slab–column-connections-reinforced concrete structure. The effect of support (shear cap) stiffness on the calculation of the length of the shear control perimeter according to the available methods is presented. Based on the analysis, the authors indicate in...
-
KOL-POL Projektowanie bezpośrednie kolumn CMC na podstawie badań polowych
ProjectsProject realized in Department of Geotechnics, Geology and Marine Civil Engineering according to PBS3/B2/18/2015 agreement from 2015-12-14
-
Ryszard Jan Barczyński dr hab. inż.
PeopleRyszard Jan Barczyński (b. 24 June 1957 in Gdańsk), Polish scientist, engineer, a specialist in solid state physics and electronic measurement techniques. In 1976, he obtained a high school diploma in the IV High School Tadeusz Kosciuszko in Torun. Higher education he graduated in 1981 at the Institute of Physics, Technical University of Gdansk in specialty of solid state physics, obtaining master's degree in engineering. Since...
-
Tiefreichende Bodenstabilisierung. Einsatz im Verkehrswegebau fuer Baugrundverbesserung und Gruendungen
PublicationPrzedstawiono ogólną klasyfikację metod wgłębnego mieszania gruntu na mokro oraz stosowane maszyny i głowice nieszające, uwzględniając systemy jedno i wielożerdziowe. Scharakteryzowano układy kolumn oraz obszary zastosowania tej technologii w inzynierii komunikacyjnej. Podano przykłady zastosowania przy budowie nasypu drogowego oraz posadowieniu podpór wiaduktu na słabym podłożu.
-
Nowoczesne metody wzmacniania słabych gruntów dla bezpiecznego posadowienia dróg. Modern ground improvement methods for soft soils and safe road constructions.
PublicationW referacie przedstawiono ciekawsze i innowacyjne w skali polskiej i europejskiej rozwiązania geotechniczne, zastosowane w ciągu kilku ostatnich lat w Polsce. Przytoczone przykłady obejmują zastosowanie: geodrenów i przeciążenia, wibroflotacji i wibrowymiany, kolum żwirowych, mieszania wgłebnego gruntu na mokro oraz kolumn betonowych ze żwirową stopą.
-
Determination of tributylotin (TBT) in marine sediment using pressurised liquid extraction-gas chromatography-isotope dilution mass spectrometry (PLE-GC-IDMS) with a hexane-tropolone mixture
PublicationOpracowano metodę oznaczania zawartości tributylocyny w próbkach osadu morskiego. Na etapie izolacji zastosowano technikę przyspieszonej ekstrakcji za pomocą roztworu tropolonu w heksanie.Na etapie oznaczeń końcowych wykorzystano technikę chromatografii gazowej, stosując metodę spektrometrii mas rozcieńczenia izotopowego. Wyznaczono parametry walidacyjne opracowanej metody: granicę wykrywalności, precyzję, poprawność i niepewność.
-
Correlated electrons and transport in a quantum point contact and in a double-quantum-dot system
Publication -
Catena-Poly[{[mu]-[eta]5:[eta]5-1-[2-(dimethylamino)ethyl-[kappa]N]cyclopentadienyl}-lithium(I)-([mu]-1,1,3,3-tetra-tert-butyltriphosphane-[kappa]3P2:P1,P3)lithium(I)]
PublicationThe title compound, [Li2(C9H14N)(C16H36P3)]n, is a by-product of the reaction of [Cp(C5H4CH2CH2NMe2)ZrCl2]n with tBu2P-P(SiMe3)Li in toluene. It is a coordination polymer composed of infinite chains running along [010]. One Li(I) atom is chelated by the cyclopentadienyl ring and and the N atom of the scorpionate ligand and a P atom, whereas the other Li(I) atom is coordinated by the backside of the cyclopentadienyl ring and two...
-
Efficient Selenenylation of Malonates Using Bis(phosphorothioyl) Diselenide
PublicationBis(O,O-diisopropoxyphosphinothioyl) diselenide reacts readily and quickly with the sodium salt of malonates to give quantitatively stable sodium 2-(O,O-diisopropyl phosphorothioselenenyl)propanedioates. No traces of the corresponding C,C-diselenenylation products were detected. A standard aqueous workup procedure affords the products, albeit in poor yield (about 45%). It was proved that the reaction is reversible due to the presence...
-
Application of microturbines in CHP systems with reciprocating engines
PublicationThe analysis was carried out for Combined Heat and Power generation systems with micro-turbines power plants working on heat rejected from the reciprocating engine. The calculations were performed for GE Jerbacher engines of J320 GS- C05, J320 GS- C25 and J416 GS- B05 types. We considered different working media (both wet and dry fluids): water, ammonia, ethanol, methanol, methylacetylene (propyne), dimethyloether, sulphur dioxide,...
-
Photocatalytic Decomposition of Air Pollutants using Electrodeposited Photocatalysts on Stainless Steel
PublicationThe aim of research was to develop an immobilization method for photocatalysts, which is an alternative to the sol-gel or dip coating methods and can be simply scaled up for technical applications. The investigated photocatalyst was TiO2, which was electrochemically deposited onto a cathode made of stainless steel. This deposited film was photocatalytically active. In order to enhance the photoactivity of the TiO2 film, commercially...
-
Mobility and biodegradability of an imidazolium based ionic liquid in soil and soil amended with waste sewage sludge
PublicationSorption on solids and biodegradation are main phenomena that can mitigate the pollution of soil and water by ionic liquids (ILs). ILs sorbed on soil particles become immobilized (temporarily or permanently) which prevents them from spreading into deeper layers of soil or groundwater but which also makes them less bioavailable. In this study we attempt to examine if amendment of soil with waste sludge has a potential to mitigate...
-
COMPUTER-AIDED CONSTRUCTION AT DESIGNING REINFORCED CONCRETE COLUMNS AS PER EC
PublicationThe article presents the author’s computer program for designing and dimensioning columns in reinforced concrete structures taking into account phenomena affecting their behaviour and information referring to design as per EC. The computer program was developed with the use of C++ programming language. The program guides the user through particular dimensioning stages: from introducing basic data such as dimensions, concrete...
-
Characteristics of calcium carbonate microparticles fabricated by the emulsion-emulsion technique in a large scale
PublicationReaktor zbudowany z dwóch współosiowych kolumn z mieszaniem w kolumnie wewnętrznej zastosowano do strącania cząstek węglanu wapnia metodą mieszania dwóch emulsji woda w oleju zawierających chlorek wapnia oraz węglan sodu jako reagenty. Zbadano wpływ częstości obrotów mieszadła, stężenia reagentów oraz czasu starzenia na wielkość cząstek stałych.
-
Distortional buckling of thin-walled columns of closed quadratic cross-section
PublicationThe elastic stability of axially compressed column related to the cross-section distortion is investigated. Two kinds of closed quadratic cross-sections are taken into consideration with internal walls and without it. The governing differential equation is derived with aid of the principle of stationary total potential energy. The critical loads for the simply supported columns are found in an analytical form and compared with...
-
Separation of CO2 from biogas using absorption columns
PublicationBiogaz zawiera ok. 50-70% metanu, 30-40% di tlenku węgla oraz niewielkie ilości innych związków jak siarkowodór czy amoniaku. Dla uzyskania wysokokalorycznego gazu konieczne jest usunięcie ze strumienia di tlenku węgla. Praca opisuje potencjał użycia do tego celu kolumn absorpcyjnych oraz cieczy jonowych jako absorbenta
-
The complexity of node blocking for dags
PublicationRozważamy następującą grę (pomiędzy dwoma graczami) kombinatoryczną o nazwie ''node blocking''. Dany jest graf skierowany. Każdy wierzchołek może być zajęty przez co najwyżej jeden token. Wyróżniamy dwa kolory tokenów, biały i czarny, każdy gracz może przemieszczać tylko własne tokeny. Gracze wykonują ruchy naprzemiennie. Ruch polega na wyborze dowolnego tokena własnego koloru i przesunięciu go na dowolnego niezajętego przez inny...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...