Filters
total: 55
Search results for: POTENTIOMETRY
-
Materials for potentiometric electrochemical gas sensors
PublicationPublikacja przeglądowa na temat zasady działania oraz rodzajów czujników elektrochemicznych gazów.
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Tuning the sumanene receptor structure towards the development of potentiometric sensors
Publication -
Potentiometric detection of organic ionics in separation methods: a critical evaluation
PublicationCzujniki potencjometryczne są w tej chwili stosowane głównie w połączeniu ze wstrzykową analizą przepływową. Badano membranowe czujniki potencjometryczne pod względem zastosowania w połączeniu z wysokosprawną chromatografią cieczową i elektroforezą kapilarną. Stosowano anality takie jak środki powierzchniowo czynne i proste leki. Zauważono, że czujniki potencjometryczne dają dobre odpowiedzi na małe i duże jony z ładunkiem wielokrotnym...
-
Potentiometric and AM1d studies of silicon podands—silver(I) complexes
Publication -
Potentiometric taste sensor application for liquid product taste estimation
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiometric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
Potentiometric and AM1d studies of silicon and phosphorous podands-silver (I) complexes
Publication -
Potentiometric and AM1d studies of silicon and boron podands—silver (I) complexes
Publication -
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Gold-modified paper as microfluidic substrates with reduced biofouling in potentiometric ion sensing
Publication -
Potentiometric and AM1d studies of a new class of Tr-podands–silver(I) complexes
Publication -
INVESTIGATION OF ACIDIC SOLUTIONS BY POTENTIOMETRIC TASTE SENSOR WITH ALL SOLID STATE ELECTRODES
PublicationPotentiometric taste sensors with electrodes containing lipophilic compound / polymer membranes were already used to distinguish commercial liquid products. In this paper a new potentiometric taste sensor consisting of six All Solid State Electrodes (ASSEs) has been presented. Each of the membrane contains a selected lipophilic compound. The set-up consists of a reference electrode and six ASSEs. The inner layer made of a conducting...
-
Potentiometric sensor with lipid-polymer membranes for quality assessment of French red wines
PublicationThe quality of wines resulting from vineyard management is important for consumers due to the taste and price of wines. In this work, the quality of red wines of three vintages has been investigated by potentiometric sensors with six all-solid-state electrodes. Two series of experiments were carried out. The first involved a qualitative analysis of wine of different vintages from freshly opened bottles. The second consisted of...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
New bis(azobenzocrown)s with dodecylmethylmalonyl linkers as ionophores for sodium selective potentiometric sensors
PublicationNovel biscrowns 1 and 2 were synthesized from 13-membered azobenzocrown ethers containing bromoalkylenoxy chains in para position relative to the azo group. The synthesized diester molecules are dodecylmethylmalonic acid derivatives differing by the linker length. The synthesized compounds have the potential of being used as sodium ionophores in ion-selective electrodes. They were characterized and used as ionophores in classic...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...
-
Comparison of Fluoride Ion-Selective Electrode Based Potentiometric Methods of Fluoride Determination in Human Urine
Publication -
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
Characterization of various drinking waters by new potentiometric taste sensor with lipid, lipid-like polymer membranes
PublicationA new sensing system comprising five all-solid-state electrodes with lipid, lipid like-polymer membranes was applied for rapid qualitative and quantitative analysis of various drinking waters. The results elaborated by chemometric methods revealed sensitivity to CO2 content in drinking water, suggesting that this sensing system could be used as a taste sensor. The ability of taste sensor to perform quantitative analysis of minerals...
-
Investigation of sweet substances of different molecular structure by potentiometric taste sensor with all solid state electrodes
PublicationA five channel potentiometric taste sensor consisting of an array of All Solid State Electrodes (ASSESs) with different lipid-polymer membranes has been developed. The electrodes are constructed of glassy carbon discs with electrochemically deposited poly(3,4-ethylenedioxythiophene) (PEDOT) acting as ion to electron transducer. The outer layer of the electrode is lipid-polymer membrane. Lipid substances immobilized in PVC membranes...
-
Qualitative and Quantitative Analysis of Selected Tonic Waters by Potentiometric Taste Sensor With All-Solid-State Electrodes
PublicationTaste sensor with five all-solid-state electrodes (ASSE) III (third version) was used for qualitative and quantitative analysis of selected tonic waters (J.Gasco, Kinley, Jurajski, Jurajski with citrus flavor, Carrefour, Schweppes Indian Tonic, and Schweppes Bitter Lemon). The results obtained by this taste sensor analyzed with principal component analysis, agglomerative hierarchical clustering methods show that this sensor can...
-
The possibility of the application of a potentiometric sensor with all-solid-state electrodes for the quality control of different natural waters
PublicationThe quality of various natural waters was examined by a new potentiometric sensor with six all solid state electrodes containing an appropriate lipophilic compound in a polymer membrane. Physicochemical parameters such as conductivity and acidity of tested waters were also tested. All waters were neutral or slightly alkaline and contained different ions (e.g., Cl–) due to the place of their sampling (a coastal zone and a moraine...
-
Investigation of sour substances by five-channel potentiometric taste sensor containing all-solid-state-electrodes ( ASSEs)
PublicationAn elaboration of taste sensor for discrimination of different food products is of great importance for food industry. Potentiometric taste sensor containing ion selective electrodes with lipid/polymer membranes has already been applied commercially in food industry. However, time-consuming and demanding preconditioning method of ions selective electrodes as well as maintenance of electrodes’ bodies are disadvantages of this taste...
-
INVESTIGATION OF SOUR SUBSTANCES BY FIVE-CHANNEL POTENTIOMETRIC TASTE SENSOR CONTAINING ALL-SOLID-STATE- ELECTRODES (ASSEs)
PublicationAn elaboration of taste sensor for discrimination of different food products is of great importance for food industry. Potentiometric taste sensor containing ion selective electrodes with lipid/polymer membranes has already been applied commercially in food industry. However, time-consuming and demanding preconditioning method of ions selective electrodes as well as maintenance of electrodes’ bodies are disadvantages of this taste...
-
Application of Potentiometric Taste Sensor with All Solid State Electrodes for Distinguishing of Red Dry Wines from Polish and French Vineyards
PublicationOpracowano nowy potencjometryczny czujnik smaku z sześcioma różnymi elektrodami typu All Solid State Electrode (ASSE). Każda z elektrod zawiera dwie warstwy: polimer przewodzący i membranę lipidowo-polimerową, w której rozpuszczone są poszczególne związki lipidowe. Potencjometryczny sensor smaku charakteryzuje się globalną selektywnością. Zastosowano go w celu odróżnienia próbek wytrawnych czerwonych win pochodzących z różnych...
-
Potentiometric sensor containing set of ion selective electrodes with lipid modified membranes for quality assessment of tested non-alcoholic beverages
PublicationPotentiometric sensors may be a good tool for fast quality control of commercial drinks. In this work, such a sensor, containing a set of ion-selective electrodes with lipid-modified membranes (benzylhexadecyldimethylammonium chloride monohydrate, hexadecylamine, 1-dodecanol, elaidic acid, cholesterol) was used for discrimination and quality control of non-alcoholic beverages, mainly composed of sugar and citric acid. It was found...
-
Dynamic impedance spectra of programmable dynamically changing RC model based on digital potentiometers
Open Research DataThe dataset presents non-stationary impedance spectra of the RC model presented in the figure below. This model contains two digital potentiometers controlled digitally by the microcontroller. This solution allows to programmably control the value of the model impedance. Thanks to this, the model can be used as a test engine for evaluation of the dynamic...
-
Copper(II) coordination properties of GxG peptides: Key role of side chains of central residues on coordination of formed systems; combined potentiometric and ITC studies
Publication -
The possibility of application of the potentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for classification of tested black leaf teas in terms of their quality
PublicationPotentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for a set of black leaf teas coming from four countries (China, India, Sri Lanka and Kenia) classification was applied. The tested tea samples were reassigned to quality classes marked with numbers I–V according to the information available. The sensor results of tea samples are presented in the form of radar charts. It was observed that, in...
-
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublicationThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublicationLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Electrocatalytic gas sensor with reference layer
PublicationIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
PublicationIn potentiometry, high selectivity of the ion-selective membranes must be assured in order to reliably measure various analytes in clinical, industrial and environmental samples. Due to the toxic nature of lead(II) it is important to monitor Pb2+ distribution in natural waters. This may be achieved by implementation of ion-selective electrodes (ISEs) with high selectivity towards lead(II) and low detection limit. A great number...
-
Wykorzystanie potencjometrów cyfrowych do testowania metod dynamicznej spektroskopii impedancyjnej
PublicationPrzedmiotem artykułu jest opracowanie modelu układu elektrochemicznego o zmiennej w czasie impedancji. Do konstrukcji modelu wykorzystano potencjometry cyfrowe sterowane mikrokontrolerem, pozwala to programowo kontrolować zmiany impedancji modelu. Odpowiednie ukształtowanie zmian widm impedancyjnych w funkcji czasu (impedancjogramów) pozwala na ustalenie ograniczeń różnych metod pomiaru impedancji.
-
Programmable dynamically changing RC model for evaluation of Dynamic EIS methods and instrumentation
PublicationThe paper concerns the RC equivalent circuit of electrochemical cell with the impedance changed during the experiment. The model was constructed using the digital potentiometers controlled by the microcontroller. This solution allows to control the model impedance by the software means. By creating adequate changes of the impedance spectrum as a time function, the different impedance measurement method can be tested to find out...
-
Juices from untypical edible fruits as acidity regulators for food industry. Verification of health promoting properties. Comparison with typical acidity regulators
PublicationThe purpose of this work was to verify possibility of using juices from selected fruits characterized by the high antioxidant potential as natural acidity regulators with improved nutritional properties. The tested fruits included: mirabelle plum, sea buckthorn, lemon and blueberry honeysuckle.The potentiometric titration was used to compare the effiacy of the juices as acidity regulators with citric acid, a widely used acidity...
-
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 16. Synthesis of 25, 26, 27, 28-tetrakis(piperidinethiocarbonylmethylene)-p-tert-butylcalix[4]arene and its interaction with metal ions
PublicationThe synthesis, characterisation and X-ray crystal structures of p-tert-butyl-calix[4]arenethioamide L and its complex with lead L-Pb2+ is reported. The cation-binding properties in solution have been assessed by liquid-liquid extraction of the metal picrates from water into dichloromethane and by stability constants determination in acetonitrile using UV-absorption spectrophotometry or potentiometry. The compound was used as active...
-
Juices from non-typical edible fruits as health-promoting acidity regulators for food industry
PublicationThe study verifies the possibility of application of juices from selected fruits characterized by the high antioxidant potential as natural acidity regulators with improved nutritional properties. The tested non-typical fruits included mirabelle plum, sea buckthorn and blue-berried honeysuckle. Beetroot juice whose pH is about 6.0 served as a model food product. Potentiometric titration was used to compare the efficacy of tested...
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Cation sensing by diphenyl-azobenzocrowns
PublicationMetal cations complexation and proton binding by 13- and 16-membered diphenyl-azobenzocrowns and diphenyl-hydroxyazobenzocrowns were studied in acetonitrile using spectroscopic methods: UV–vis spectroscopy, spectrofluorimetry, and 1H NMR spectroscopy. Phenyl moieties in benzene rings were found to affect binding strength alkali and alkaline earth metal cations and hydrogen ion, and affect tautomeric equilibrium of hydroxyazobenzocrowns....
-
Combination of instrumental and qualitative descriptive analysis for evaluation of selected tonic waters quality features
PublicationThe combination of sensory and instrumental analysis was applied for quality assurance of selected tonic waters. The Quantitative Descriptive Analysis (QDA) in terms of fourteen sensory attributes (aroma, astringency, bite, burn, numbing, tongue heaviness, carbonation, mouth coating, sweet taste, sour taste, bitter taste, sweet aftertaste, sour aftertaste, bitter aftertaste) of selected tonic waters was performed by sensory experts....
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Food analysis using artificial senses.
PublicationNowadays, consumers are paying great attention to the characteristics of food such as smell, taste, and appearance. This motivates scientists to imitate human senses using devices known as electronic senses. These include electronic noses, electronic tongues, and computer vision. Thanks to the utilization of various sensors and methods of signal analysis, artificial senses are widely applied in food analysis for process monitoring...
-
Solid-Contact Ion-Selective Electrodes with Highly SelectiveThioamide Derivatives of p-tert-Butylcalix[4]arene for theDetermination of Lead(II) in Environmental Samples
PublicationThioamide derivatives of p-tert-butylcalix[4]arene were used as ionophores in the development of solid-contact ion-selective electrodes based on conducting polymer poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) which was synthesized by electrodeposition on the glassy carbon electrodes. The typical ion-selective membranes with optionally two different plasticizers [bis(2-ethylhexyl)sebacate (DOS) and 2-nitrophenyl...
-
Simultaneous determination of Na+, K+, Ca2+, Mg2+ and Cl- in unstimulated and stimulated human saliva using all solid state multisensor platform
PublicationHuman saliva is one of the body fluids which collection method is relatively simple and non-invasive. The article is dedicated to assess concentration (activity) of Na+, K+, Ca2+, Mg2+ and Cl- in fresh, unstimulated or stimulated human saliva samples using single solid contact ion-selective electrodes with conventional reference electrode and self-made multisensor platform (MP) equipped with ion-selective membranes for Na+, K+,...
-
TASTE QUALITIES ESTIMATION BY TASTE SENSE AND ELECTROCHEMICAL SENSORS
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiom etric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
All solid state electrodes taste sensor with modified polymer membranes for discrimination of mineral water with different CO2 content
PublicationA potentiometric taste sensor with All Solid State Electrodes containing five all solid state electrodes with appropriate lipophilic compounds (benzyldimethyltetradecylammonium chloride, dodecyltrimethylammonium bromide, palmitic acid, stearic acid, and phytol) embedded in a polymer membrane was applied for discrimination of mineral water samples differed in CO2 content. Samples of still, slightly sparkling, and sparkling Naleczowianka...
-
Low-Molecular Pyrazine-Based DNA Binders: Physicochemical and Antimicrobial Properties
PublicationPyrazine and its derivatives are a large group of compounds that exhibit broad biological activity, the changes of which can be easily detected by a substituent effect or a change in the functional group. The present studies combined theoretical research with the density functional theory (DFT) approach (B3LYP/6-311+G**) and experimental (potentiometric and spectrophotometric) analysis for a thorough understanding of the structure...
-
Electrochemical synthesis of 2D copper coordination-polymers: Layer-stacking deviation induced by the solvent and its effect on the adsorptive properties
PublicationA 2D Cu-based Metal-Organic Framework (MOF), namely copper-terephthalate (Cu(1,4-BDC)), was successfully synthesized by electrochemical method for effective methylene blue (MB) sorption from aqueous solutions. The composition, morphology, and the presence of functional groups in the obtained material were verified by Fourier Transform Infrared spectroscopy (FTIR), Powder X-Ray Diffraction (PXRD), Thermal (TGA), and Elemental (EA)...