Filtry
wszystkich: 2321
wybranych: 377
-
Katalog
- Publikacje 1910 wyników po odfiltrowaniu
- Czasopisma 5 wyników po odfiltrowaniu
- Konferencje 2 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 12 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Kursy Online 12 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 377 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: frequency band gaps
-
Impedance spectra of ZnO varistor type 280 model 0 ver. 89
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model O ver. 68
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 100 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 440 model O ver. 68
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model O M ver. 65 60
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Electrochemical impedance spectra and CV curves of V2O5 nanocrystals
Dane BadawczeThe DataSet contains the EIS spectra for coin-cells and CV curves with the V2O5 nanocrystals obtained by the sol-gel method. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were measured using the AUTOLAB 302N potentiostat-galvanostat under Nova software. The EIS measurements were recorded in the frequency range 100 kHz to 10 mHz...
-
Electrochemical impedance spectra and CV curves of V2O5 nanorods
Dane BadawczeThe DataSet contains the EIS spectra for coin-cells and CV curves with the V2O5 nanorods obtained by the sol-gel method. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were measured using the AUTOLAB 302N potentiostat-galvanostat under Nova software. The EIS measurements were recorded in the frequency range 100 kHz to 10 mHz for...
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Nonlinear impedance of vanadate glass-ceramics containing BaTiO3
Dane BadawczeThe nonlinear impedance of vanadate glasses doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials during maneuvering.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Raman spectroscopy analysis of poly(lactic acid)-carbon black composite treated by femtosecond laser
Dane BadawczeThe dataset contains the Raman spectroscopy measurements of commercially available carbon black-filled poly(lactic acid) 3D printed electrodes after femtosecond laser ablation. These results were utilized in the manuscript published in Electrochimica Acta: 10.1016/j.electacta.2022.140288
-
Measurements of ultrasonic bulk and guided wave propagation in additively manufactured cubes and plates obtained by ultrasonic pulse velocity analyzer and scanning laser vibrometry
Dane BadawczeThe DataSet contains the results of measurements of ultrasonic wave propagation in additively manufactured samples made of polylactic acid (PLA). Three types of raster angles in two consecutive layers were assumed: 0°/90° (#1), 45°/-45° (#2) and 90°/90° (#3) with respect to the x-axis. For each printing variants a cubic sample (#C1-3) with dimensions...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Dane BadawczeThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Dane BadawczeThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Skin Conductance Level (SCL) data collected during mental training of group of 30 athletes
Dane BadawczeThe dataset contain raw Skin Conductance Level (SCL) data, collected at a frequency of 40 Hz and expressed in units of microsiemens (μS), during mental training of group of 30 athletes, under the project "Psychophysiology of guided and self-produced imagery in sport".
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 200 mV
Dane BadawczeThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 0 V
Dane BadawczeThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 600 mV
Dane BadawczeThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for detection of organic gases (ethanol, acetone)
Dane BadawczeCarbon nanotube networks of different optical transparencies were investigated via resistance and 1/f noise measurements for detection of ethanol and acetone. The sensor resistive and noise responses were collected for dark and UV-assisted conditions, revealing the improvement in sensor sensitivity and limit of detection after applying UV light (275...
-
Transmission measurements between two geometrically small Vivaldi antennas performed in non-anechoic propagation conditions
Dane BadawczeThe dataset contains unprocessed measurements of complex transmission (and reflection) characteristics obtained in non-anechoic regime for a geometrically small, broadband spline-parameterized Vivaldi structure. The measurement setup comprises two Vivaldi antennas with the same topology where one is used as a reference structure, and another one as...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 400 mV
Dane BadawczeThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
The database of interpolated RR-intervals of original length 512 of 41 patients at rest hospitalized due to the episode of acute ischemic stroke
Dane BadawczeThis dataset contains the data that was a basis for the results discussed in the paper “Persistent homology as a new method of the assessment of heart rate variability” by Grzegorz Graff, Beata Graff, Paweł Pilarczyk, Grzegorz Jabłoński, Dariusz Gąsecki, Krzysztof Narkiewicz, Plos One (2021), DOI: 10.1371/journal.pone.0253851.
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 glass-ceramic annealed at 423 K measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic annealed at 423 K prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
The database of interpolated RR-intervals of length 512 of 46 healthy subjects at rest
Dane BadawczeThis dataset contains the data that was a basis for the results discussed in the paper “Persistent homology as a new method of the assessment of heart rate variability” by Grzegorz Graff, Beata Graff, Paweł Pilarczyk, Grzegorz Jabłoński, Dariusz Gąsecki, Krzysztof Narkiewicz, Plos One (2021), DOI: 10.1371/journal.pone.0253851.
-
Ultrasonic wave propagation and digital image correlation measurements of steel bars under 3-point bending
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a bar under a 3-point bending test. The bar was made of steel and had a cross-section of 5.96 × 5.96 mm2 and a length of 200 mm. The three-point bending test was performed using a Zwick/Roell Z10 universal testing machine (UTM), with a distance between supports of 12 cm. The parameters...
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Sliding friction of alumina (Al2O3) with friction induced vibrations
Dane BadawczeTest files containing data on experiments in self mated sliding contact of alumina Al2O3 lubricated with either water or paraffin oil. Tests run in variable load/velocity conditions and with different dynamic settings of the test rig (PT-3 tribometer). The aim of the research was to attempt in finding correlations between the dynamic characteristics...
-
Elastic wave propagation signals in concrete cube (experimental and calculated using discrete element method)
Dane BadawczeThe DataSet contains the results of the elastic wave propagation. Both experimental and numerical signals were obtained for the concrete cube with dimensions of 50 × 50 × 50 mm3. The specimen was made of concrete with called mortar concrete. The ingredients of the concrete mix were as follows: CEM I 42.5R (500 kg/m3), sand 0 – 2 (1500 kg/m3) and water...
-
Dynamic impedance spectra of programmable dynamically changing RC model based on digital potentiometers
Dane BadawczeThe dataset presents non-stationary impedance spectra of the RC model presented in the figure below. This model contains two digital potentiometers controlled digitally by the microcontroller. This solution allows to programmably control the value of the model impedance. Thanks to this, the model can be used as a test engine for evaluation of the dynamic...
-
Radiation pattern measurements of geometrically small antennas performed in non-anechoic environments
Dane BadawczeThe dataset contains unprocessed measurements of radiation pattern characteristics performed in non-anechoic regime for three geometrically small antenna structures: a spline-parameterized Vivaldi structure, a compact spline-based monopole, and a quasi-Yagi geometry with enhanced bandwidth. The responses have been obtained over broad frequency ranges...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Electrochemical cell impedance spectra at Eoc+100mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-100mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Linear impedance of V2O5 nanorods obtained at 903K
Dane BadawczeThe DataSet contains the linear electrical properties of V2O5 nanorods which were measured by the impedance spectroscopy method. V2O5 nanorods were obtained by the sol-gel method. The information about xerogel powder synthesis is described in the Journal of Nanomaterials. The precursor powder was pressed into the disk-shaped pellets (12mm in diameter...
-
The database of normal RR-intervals of length up to 512 of 41 patients at rest hospitalized due to the episode of acute ischemic stroke
Dane BadawczeThis dataset contains the data that was a basis for the results discussed in the paper “Persistent homology as a new method of the assessment of heart rate variability” by Grzegorz Graff, Beata Graff, Paweł Pilarczyk, Grzegorz Jabłoński, Dariusz Gąsecki, Krzysztof Narkiewicz, Plos One (2021), DOI: 10.1371/journal.pone.0253851.
-
The database of normal RR-intervals of length up to 512 of 46 healthy subjects at rest
Dane BadawczeThis dataset contains the data that was a basis for the results discussed in the paper “Persistent homology as a new method of the assessment of heart rate variability” by Grzegorz Graff, Beata Graff, Paweł Pilarczyk, Grzegorz Jabłoński, Dariusz Gąsecki, Krzysztof Narkiewicz, Plos One (2021), DOI: 10.1371/journal.pone.0253851.