Filtry
wszystkich: 1581
wybranych: 550
-
Katalog
- Publikacje 956 wyników po odfiltrowaniu
- Czasopisma 1 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Osoby 8 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 10 wyników po odfiltrowaniu
- Dane Badawcze 603 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: measurement system
-
Experimental Study of the Influence of Noise Level on the Uncertainty Value in a Measurement System Containing an Analog-to-Digital Converter
Dane BadawczeFor newly developed measuring systems it is easy to estimate type B uncertainties based on the technical data of the measuring modules applied. However, it is difficult to estimate A type un-certainties due to the unknown type and level of interferences infiltrating into the measuring sys-tem. This is a particularly important problem for measurements...
-
Selected results of measurements carried out in a ship power station with two generators working in parallel with the use of the NI PXIe-1062Q based measurement system
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (A/E v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering, of Gdynia Maritime University. The attached data set contains the results of measurements made...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bathtub, the other side of the bathtub is grounded and the system ground is grounded- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Park and Ride system in Gdansk 2020- video traffic data
Dane BadawczePark and Ride system in Gdansk 2020- video traffic data
-
Development of conductive porous media as packing materials for biotrickling filter – microbial fuel cell system (BTF-MFC system)
Dane BadawczeDataset presents values of electrical resistance measured for three developed conductive packimg materials for the application in a BTF-MFC system.
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors_part_2
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Calculations of the resistance values of 10 ratio resistors
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
The harmonic distortion of voltage waveforms in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the ship's electrical power system's main switchboard in different states of ship exploitation. The attached dataset contains the results of a harmonic distortion analysis expressed by the total harmonic distortion (THD) coefficient of voltage waveforms recorded...
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a sea voyage.
-
Long-term measurement of physiological parameters.
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during maneuvering.
-
Long-term measurement of physiological parameters (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a layover at the port
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a layover at the port.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during maneuvering.
-
Measurements of the mechanical system properties of "SpeedLine magnetic" ultra-fast robot prototype for IML labeling
Dane BadawczeThe mechanical system tests of the high-speed IML labeling robot "SpeedLine Magnetic" were carried out in order to analyze the effects of the drive system's operating parameters on vibration and noise.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
Long-term measurement of physiological parameters - a teenager (4h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (13h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (13 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (10h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (10 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
Long-term measurement of physiological parameters - adult (120 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (60 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.
-
Long-term measurement of physiological parameters - a teenager (9h and 20min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (9 hours and 20 minutes) measurement of physiological parameters was performed on...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials during maneuvering.
-
Measurement of the temperature change of PVCP tissue phantom illuminated by dermatological laser 1.series
Dane BadawczeApplication of laboratory set-up for characterization of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes a thermographic camera VIGOcam v50 and a dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 6th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 5 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 12. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 11. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 2 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 7th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 10th series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (150 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 150 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 9th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 4 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 8th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a layover at the port
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a layover at the port.
-
AeroSense Measurements: Aventa AV-7 Taggenberg Winter 2022-2023 Campaign
Dane BadawczeData from field tests of Aerosesne measurement system installed on Avneta AV-7 wind turbine, located in Taggenberg (ZH), Switzerland. Dataset contains intermittent 10 minute long measurement sessions from 40 barometers, and IMU system installed on the wind turbine blade at r/R = 0.740625. The measurement campaign was performed between 01.DEC.2022 and...
-
Calculations of the resistance values of 20 thermistors at 100°C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Calibration of NTC 10k thermistors in temperature of 50 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calculations of the resistance values of 20 thermistors at 0°C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calculations of material factors for a set of 20 thermistors
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Measurements of the fundamental harmonic frequency of voltages on main bars in a ship power station
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the fundamental...
-
Measurements of the rms voltages on main bars in a ship power station with two generators operating in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the rms...
-
Measurements of the rms currents in two phases in a ship power station with two generators operating in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the rms...
-
ECG measurement in the bathtub - getting into the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Measurements of apparent power distribution in a ship power station with two generators working in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing an apparent...
-
Measurements of the coefficients of current distribution between two generators operating in parallel in a ship power station
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the coefficients...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um.
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Measurements of active power coefficients in a ship power station with two generators working in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing active...
-
Measurements of the coefficients of active power distribution between two generators operating in parallel in a ship power station
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing coefficients...
-
Measurements of active power distribution in a ship power station with two generators working in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data expressing an active...
-
Measurements of reactive power distribution in a ship power station with two generators working in parallel
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing a reactive...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Calculations of the resistance values of 20 thermistors at 50°C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 0 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 100 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a bow thruster start-up
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. In ships' electrical power systems, disturbances occurring in voltage waveforms on bus bars of the main switchboard are connected mainly with the processes...
-
The short-term flicker severity level measured in the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents a short-term flicker severity level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 90 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 180 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 60 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 190 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 70 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...