Filtry
wszystkich: 24
Wyniki wyszukiwania dla: AMPEROMETRIC TECHNIQUES
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublikacjaIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
-
Microfluidic devices for photo-and spectroelectrochemical applications
PublikacjaThe review presents recent developments in electrochemical devices for photo- and spectroelectrochemical investigations, with the emphasis on miniaturization (i.e., nanointerdigitated complementary metal-oxide-semiconductor devices, micro- and nano-porous silicon membranes or microoptoelectromechanical systems), silica glass/microreactors (i.e., plasmonic, Raman spectroscopy or optical microcavities) or polymer-based devices (i.e.,...
-
Application of Ionic Liquids in Amperometric Gas Sensors
PublikacjaThis article presents an analysis of available literature data on metrological parameters of the amperometric gas sensors containing ionic liquids as an electrolyte. Four mechanism types of signal generation in amperometric sensors with ionic liquid are described. Moreover, this article describes the influence of selected physico-chemical properties of the ionic liquids on the metrological parameters of these sensors. Some metrological...
-
Determination of Chemical Oxygen Demand (COD) at Boron-doped Diamond (BDD) Sensor by Means of Amperometric Technique
PublikacjaA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Determination of chemical oxygen demand (cod) at boron-doped diamond (bdd) sensor by means of amperometric technique
PublikacjaA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublikacjaIn this work amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode will be presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been investigated.
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublikacjaIn this work investigation of an amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode properties is presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been studied.
-
Identification of defected sensors in an array of amperometric gas sensors
PublikacjaPurpose Amperometric gas sensors are commonly used in air quality monitoring in long-term measurements. Baseline shift of sensor responses and power failure may occur over time, which is an obstacle for reliable operation of the entire system. The purpose of this study is to check the possibility of using PCA method to detect defected samples, identify faulty sensor and correct the responses of the sensor identified as faulty. Design/methodology/approach In...
-
Electrochemical synthesis of 2D copper coordination-polymers: Layer-stacking deviation induced by the solvent and its effect on the adsorptive properties
PublikacjaA 2D Cu-based Metal-Organic Framework (MOF), namely copper-terephthalate (Cu(1,4-BDC)), was successfully synthesized by electrochemical method for effective methylene blue (MB) sorption from aqueous solutions. The composition, morphology, and the presence of functional groups in the obtained material were verified by Fourier Transform Infrared spectroscopy (FTIR), Powder X-Ray Diffraction (PXRD), Thermal (TGA), and Elemental (EA)...
-
Gas mixtures recognition using an array of amperometric gas sensors with drifting or faulty sensors
PublikacjaIn this study, the possibility of using selected methods for diagnostics of performance of matrix composed with six amperometric electrochemical gas sensors is investigated. Measurements of sensor responses in selected concentrations of single toxic gases or gas mixtures were performed and were repeated over time to show sensor drift. Additionally, the studies on the sensors’ drift were performed. The drift has been recognized...
-
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publikacja.A boron-doped diamond (BDD) sensor is proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Boron-doped diamond thin films, acting as active sensors, were deposited on both silicon wafer and glassy carbon (GC) substrates by microwave plasma assisted chemical vapour deposition. SEM micrographs showed that BDD–Si displays triangle-faceted crystallites ca. 0.5–3 μm in size, while BDD–GC...
-
Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air
PublikacjaThe paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones....
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublikacjaThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
PublikacjaA simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat...
-
Recurrent potential pulse technique for improvement of glucose sensing ability of 3D polypyrrole
PublikacjaIn this work, a new approach for using a 3D polypyrrole (PPy) conducting polymer as a sensing material for glucose detection is proposed. Polypyrrole is electrochemically polymerized on a platinum screen-printed electrode in an aqueous solution of lithium perchlorate and pyrrole. PPy exhibits a high electroactive surface area and high electrochemical stability, which results in it having excellent electrocatalytic properties. The...
-
Evaluation of the Electronic Nose Used for Monitoring Environmental Pollution
PublikacjaAir pollution is a one of the major concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. Electronic-nose systems based on sensors are an interesting and promising technology in...
-
Selectivity of amperometric gas sensors in multicomponent gas mixtures
PublikacjaIn recent years smog and poor air quality became a growing environmental problem. There is a need to continuously monitor the quality of air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, a selectivity of the six amperometric gas sensors is being investigated. Calibration of sensors has been performed in order to find a correlation between concentration...
-
Electrocatalytic gas sensor with reference layer
PublikacjaIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
Limited selectivity of amperometric gas sensors operating in multicomponent gas mixtures and methods of selectivity improvement
PublikacjaIn recent years, smog and poor air quality have became a growing environmental problem. There is a need to continuously monitor the quality of the air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, the selectivity of six amperometric gas sensors is investigated. First, the sensors were calibrated in order to find a correlation between the concentration...
-
Ion Chromatography with Pulsed Amperometric Detection for Determining Cyanide in Urine and Meconium Samples
PublikacjaThe parents’ addictions and eating habits have a significant influence on the child’s growth. The first stool of a newborn baby provides a large amount of information about xenobiotics transmitted by the mother’s body. The analytical technique used in the study is ion chromatography with pulsed amperometric detection (IC-PAD). The biological samples, which were obtained from women staying in a maternity ward and their partners,...
-
Preparation and characterisation of solution-cast Nafion membrane
PublikacjaNafion is a commercial name for a perfluorosulfonic polymer, which has been developed in 1962 by Dupont de Nemours. This polymer consists of a polytetrafluoroethylene backbone and regular spaced long perfluorovinyl ether pendant side chains terminated by a sulfonate ionic group. These sulfonate groups are responsible for cation-exchange properties of Nafion. Thanks to the ion-exchange properties, water permeability, good chemical,...
-
Determination of cyanide in urine and saliva samples by ion chromatography with pulsed amperometric detection
PublikacjaCommonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes. It naturally occurs in plant seeds as a cyanogenic glycosides. Another relatively common mode of cyanide exposure is inhalation of environmental tobacco smoke. This study concerns importance to determine cyanide ion in human biological samples. Urine and saliva samples were collected healthy volunteers exposed to tobacco...
-
Application of ion chromatography with pulsed amperometric detection for the determination of trace cyanide in biological samples, including breast milk
PublikacjaCyanide (CN) is the biomarker of exposure to the components of tobacco smoke, although its presence in biological samples is also due to the consumption of products containing cyanogenic glycosides. In this work, we determine the concentration of the free cyanide in urine, saliva and breast milk matrices, using ion chromatography with pulsed amperometric detection (IC-PAD). IC-PAD is an emerging method, with only few documented...
-
Tailoring Diffusional Fields in Zwitterion/Dopamine Copolymer Electropolymerized at Carbon Nanowalls for Sensitive Recognition of Neurotransmitters
PublikacjaThe importance of neurotransmitter sensing in the diagnosis and treatment of many psychological illnesses and neurodegenerative diseases is non-negotiable. For electrochemical sensors to become widespread and accurate, a long journey must be undertaken for each device, from understanding the materials at the molecular level to real applications in biological fluids. We report a modification of diamondized boron-doped carbon nanowalls...