Filtry
wszystkich: 33
wybranych: 28
-
Katalog
Filtry wybranego katalogu
Wyniki wyszukiwania dla: PHANTOMS
-
Measurements of fundamental properties of homogeneous tissue phantoms
PublikacjaWe present the optical measurement techniques used in human skin phantom studies. Their accuracy and the sources of errors in microscopic parameters’ estimation of the produced phantoms are described. We have produced optical phantoms for the purpose of simulating human skin tissue at the wavelength of 930 nm. Optical coherence tomography was used to measure the thickness and surface roughness and to detect the internal inhomogeneities....
-
Nanoparticle-free tissue-mimicking phantoms with intrinsic scattering
PublikacjaWe present an alternative to the conventional approach, phantoms without scattering nanoparticles, where scattering is achieved by the material itself: spherical cavities trapped in a silicone matrix. We describe the properties and fabrication of novel optical phantoms based on a silicone elastomer polydimethylsiloxane (PDMS) and glycerol mixture. Optical properties (absorption coefficient µa, reduced scattering coefficient µs',...
-
Use of optical skin phantoms for calibration of dermatological lasers
PublikacjaA wide range of dermatological diseases can be efficiently treated using laser heating. Nevertheless, before the new laser is introduced into clinical practice, its parameters and ability to interact with human skin have to be carefully examined. In order to do that optical skin phantoms can be used. Such phantoms closely imitate the scattering and absorption properties of real human skin tissue along with its thermal properties,...
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublikacjaExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublikacjaThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...
-
Polyacrylamide‐based phantoms as tissue substitute in experimental radiation physics
Publikacja -
Investigation of photothermolysis therapy of human skin diseases using optical phantoms
PublikacjaDermatological diseases, such as neurofibroma (Recklinghausen disease) or hemangiomas can be efficiently treated using photothermolysis from laser irradiation. We have utilized a developed 975 nm fiber diode laser as a low-cost alternative over common Nd:YAG lasers. This paper describes the investigations of interaction of 975 nm diode laser radiation-pulses with optical skin phantoms which were designed and manufactured in our...
-
Full scattering profile of circular optical phantoms mimicking biological tissue
PublikacjaHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. In our poster, we suggest a new type of skin phantom and an optical method for sensing physiological tissue condition, basing on the collection of the ejected light at all exit angles, to receive the full scattering profile. Conducted experiments were carried out on an unique set-up for noninvasive encircled measurement. Set-up consisted...
-
T1 RELAXATION TIME CALLIBRATION IN MAGNETIC RESONANCE IMAGING USING NANODIAMOND PHANTOMS
PublikacjaMRI is increasingly used in radiation treatment planning because of the excellent soft tissue contrast in the obtained images. It allows more precise definition of the boundaries between healthy tissues and those affected by cancerous lesions. To obtain good image quality, the difference in signal between two types of tissue must be significant despite the noise so it must be properly calibrated. This calibration includes...
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublikacjaIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Porous Phantoms Mimicking Tissues—Investigation of Optical Parameters Stability Over Time
PublikacjaOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods, while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom in optical system. Measurements were performed in multiple series with an interval...
-
Colored Tattoo Ink Screening Method with Optical Tissue Phantoms and Raman Spectroscopy
PublikacjaDue to the increasing popularity of tattoos among the general population, to ensure their safety and quality, there is a need to develop reliable and rapid methods for the analysis of the composition of tattoo inks, both in the ink itself and in already existing tattoos. This paper presents the possibility of using Raman spectroscopy to examine tattoo inks in biological materials. We have developed optical tissue phantoms mimicking...
-
A Measurement System for Quasi-Spectral Determination of Absorption and Scattering Parameters of Veterinary Tissue Phantoms
PublikacjaThis paper describes the construction of a system for the quasi-spectral determination of absorption and scattering parameters of animal tissue phantoms. Several tissue phantoms, including one reference and two modified for examination, were prepared from polydimethylsiloxane (PDMS). The phantoms were measured using a system based on an integrating sphere and the light sources of wavelengths commonly used for the treatment of various...
-
Use of optical skin phantoms for preclinical evaluation of laser efficiency for skin lesion therapy
PublikacjaSkin lesions are commonly treated using laser heating. However, the introduction of new devices into clinical practice requires evaluation of their performance. This study presents the application of optical phantoms for assessment of a newly developed 975-nm pulsed diode laser system for dermatological purposes. Such phantoms closely mimic the absorption and scattering of real human skin (although not precisely in relation to...
-
Model of optical phantoms thermal response upon irradiation with 975 nm dermatological laser
PublikacjaWe have developed a numerical model describing the optical and thermal behavior of optical tissue phantoms upon laser irradiation. According to our previous studies, the phantoms can be used as substitute of real skin from the optical, as well as thermal point of view. However, the thermal parameters are not entirely similar to those of real tissues thus there is a need to develop mathematical model, describing the thermal and...
-
Heterogeneity phantoms for visualization of 3D dose distributions by MRI‐based polymer gel dosimetry
Publikacja -
Nanodiamond phantoms mimicking human liver: perspective to calibration of T1 relaxation time in magnetic resonance imaging
PublikacjaPhantoms of biological tissues are materials that mimic the properties of real tissues. This study shows the development of phantoms with nanodiamond particles for calibration of T1 relaxation time in magnetic resonance imaging. Magnetic resonance imaging (MRI) is a commonly used and non-invasive method of detecting pathological changes inside the human body. Nevertheless, before a new MRI device is approved for use, it is necessary...
-
Reply to Comment on ‘Nanodiamond incorporated human liver mimicking phantoms: prospective calibration medium of magnetic resonance imaging’
PublikacjaDependence of the spin–lattice (T1) relaxation times on the nanodiamond concentration in human liver phantoms is discussed. Factors affecting stability and and reproducibility of these phantoms are presented. The need for comparative measurements on multiple MRI scanners for better understanding of potential variations in the obtained imaging data is emphasised.
-
Continuous three-dimensional radiation dosimetry in tissue-equivalent phantoms using electron paramagnetic resonance in L -α-alanine
Publikacja -
Corrigendum to “T1 relaxation time callibration in magnetic resonance imaging using nanodiamond phantoms” [Phys Med 94 (2022) S119–S120/EPV029]
PublikacjaThe authors want to update the incorrect funding information. The correct funding note is: “The authors acknowledge the financial support from Gdańsk University of Technology by the 4/2020/IDUB/III.4.1/Tc grant under the Technetium Talent Management Grants ‘Excellence Initiative – Research University’. The financial support from Gdańsk University of Technology by the 1/2021/IDUB/II.2/Np grant under NEPTUNIUM Enhancing Baltic Region...
-
Blood equivalent phantom vs whole human blood, a comparative study
PublikacjaPreclinical research of biomedical optoelectronic devices is often performed with the use of blood phantoms — a simpli¯ed physical model of blood. The aim of this study is the comparison and distinction between blood phantoms as well as whole human blood measurements. We show how the use of such phantoms may in°uence the incorrect interpretation of measured signal. On the other hand, we highlight how the use of blood phantoms enables...
-
Experimental results of full scattering profile from finger tissue-like phantom
PublikacjaHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. We suggest a new optical method for sensing physiological tissue state, based on the collection of the ejected light at all exit angles, to receive the full scattering profile. We built a unique set-up for noninvasive encircled measurement. We use a laser, a photodetector and finger tissues-mimicking phantoms presenting different optical...
-
IoT for healthcare applications
PublikacjaThis chapter summarizes IRACON contributions related to the application of IoT in healthcare. It consists of the following three sections. Section 8.1 presents the measurement campaigns and the related statistical analysis to obtain various channel models for wearable and implantable devices. In addition, the importance of physical human-body phantoms used for channel, Specific Absorption Rate (SAR), and Electromagnetic (EM) exposure...
-
Measurement of the Temporal and Spatial Temperature Distribution on the Surface of PVCP Tissue Phantom Illuminated by Laser Dataset
PublikacjaThe dataset entitled Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser was obtained with a laboratory set-up for characterisation of the thermal properties of optical tissue phantoms during laser irradiation. The dataset contains a single image file representing the spatial temperature distribution on the surface of a PVCP tissue phantom. This thermal image...
-
Automatic system for optical parameters measurements of biological tissues
PublikacjaIn this paper a system allowing execution of automatic measurements of optical parameters of scattering materials in an efficient and accurate manner is proposed and described. The system is designed especially for measurements of biological tissues including phantoms, which closely imitate optical characteristics of real tissue. The system has modular construction and is based on the ISEL system, luminance and color meter and...
-
Raman spectroscopic investigation of blood and related materials
PublikacjaThis paper reports preliminary studies on use of Raman spectroscopy for investigation of blood. High quality blood spectra were recorded in-vitro with excitation wavelengths of 830 nm. Because of complex composition of the blood as well as by light attenuation and scattering in the tissues, spectra set up from wide, low-intensive Raman bands and intensive optical background. To get information about origin of bands in Raman spectra...
-
Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation
PublikacjaIn brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublikacjaNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...