Filtry
wszystkich: 2016
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: ALLERGY TO IMPLANT COMPONENTS
-
Allergy to implant components: chromium, nickiel, cobalt and titanium
PublikacjaImplant jest kompozycja roznych pierwiastkow: niklu, chromu, kobaltu, tytanu, molibdenu i wanadu. Pierwiastki te moga doprowadzic do alergii, egzemy i obluzowania implantu.
-
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublikacjaDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublikacjaDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Marcin Wekwejt dr inż.
OsobyMarcin Wekwejt, absolwent studiów inżynierskich w inż. biomedycznej (2016; Politechnika Bydgoska im. J. i J. Śniadeckich & Collegium Medicum im. L. Rydygiera), studiów magisterskich w inż. mechaniczno-medycznej (2018; Politechnika Gdańska & Gdański Uniwersytet Medyczny) oraz studiów doktoranckich w dyscyplinie inż. materiałowej (2021, Politechnika Gdańska). Uzyskał z wyróżnieniem stopień naukowy doktora nauk inżynieryjno-technicznych...
-
The biological reactions on the implant-organism border
PublikacjaMateriał przeznaczony do implantacji w tkanki żywego organizmu powinien być biozgodny i biofunkcjonalny. Jeśli tak nie jest, ciało reaguje stanem zapalnym. Reakcje zapalne mogą się objawiać np. odrywaniem się cząstek materiału z powierzchni implantu na skutek tarcia lub nacisku, lub wytworzeniem biofilmu na jego powierzchni.
-
IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS
Czasopisma -
Robert Bogdanowicz dr hab. inż.
OsobyRobert Bogdanowicz received his Ph.D. degree with honours in Electronics from the Gdansk University of Technology. He worked as a post-doc researcher in Ernst-Moritz-Arndt-Universität Greifswald Institut für Physik. He has initiated optical emission imaging of muti-magnetron pulsed plasma and contributed to the development of antibacterial implant coatings deposited by high-power impulse magnetron sputtering. He moved back to...
-
Surgical implant used in ventral hernia repair subjected to physiological pressure - computer simulation
PublikacjaW streszczeniu przedstawiono matemayczny model implantu wszczepionego pacjentowi podczas laparoskopowej naprawy przepukliny brzusznej. Wykonano go z użyciem metody elementów skończonych. Przyjęto ortotropowy model materiałowy implantu.
-
A EuroPrevall review of factors affecting incidence of peanut allergy: priorities for research and policy
Publikacja -
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublikacjaThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [3300730069445181]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541212901]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541214921]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541212601]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541212331]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541214991]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541219801]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541211191]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 42 - Tissue image [10040729541212031]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 42 - Tissue image [10040729541217341]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 42 - Tissue image [10040729541219141]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 42 - Tissue image [10040729541216851]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Zastosowanie próby implant do oceny spawalności stali
PublikacjaPraca dotyczy oceny spawalności stali o podwyższonej i wysokiej wytrzymałości w aspekcie eksperymentalnego określania skłonności do tworzenia pęknięć zimnych. W artykule opisano metodykę określania wrażliwości na pękanie próbą implant. Przedstawiono również proponowane w literaturze i autorskie sposoby opracowywania i przedstawiania wyników badań rozpatrywaną metodą i ich interpretacji.
-
Trudności podczas modelowania próby implant w programie Ansys.
PublikacjaW artykule przedstawiono trudności związane ze stworzeniem modelu próby implant w programie Ansys. Określono również trudności związane z przypisaniem odpowiednim strefom połączenia spawanego własności mechanicznych.
-
Implant Dentistry
Czasopisma -
IMPLANT USED IN HERNIA REPAIR UNDER PHYSIOLOGICAL MOVEMENTS OF HUMAN ABDOMEN
PublikacjaThe study deals with the mechanical behaviour of implant used in repair of abdominal hernia. The influence of orientation of the orthotropic implants in different areas of abdominal wall is studied.
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublikacjaThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
-
Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair
PublikacjaEven though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...
-
Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation
Publikacjarelation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients’ life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical...
-
Mathematical study of a tissue-implant connection in a ventral herniarepair in a context of the system's parameters
PublikacjaW pracy przedstawiono problem operowania przepuklin brzusznych u ludzi. Zaproponowano jednowymiarowy model układu powieź-implant. Na podstawie analizy wrażliwości zidentyfikowano najważniejsze parametry problemu.
-
Health effects of food components
Kursy Online -
Health effects of food components
Kursy Online -
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublikacjaIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublikacjaThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
Dynamics of mechanical model of implant-tissue system in ventral hernia repair
PublikacjaThe paper deals with a finite element modelling of implants in the problem of ventral hernia repair. The synthetic mesh implanted in the abdomen during surgery is here modelled as a membrane structure. Thesystem undergoes the internal abdominal pressure that occurs during the postoperative cough, the load identified in the literature as the main cause of the connection failure and hernia recurrence. The model can be used to estimate...
-
A FEM membrane model of human fascia-synthetic implant system in a case of a stiff ventral hernia orifice
PublikacjaPraca prezdstawia model matematyczny układu tkanka ludzka - implant syntetyczny w postaci tzw. siatki w leczeniu przepuklin brzusznych. Implant jest tu moelowany jako struktura membranowa. Ocena wpływu danych materiałowych oraz wstępnego napięcia na zachowanie pracującej membrany po implantacji została przedstawiona na podstawie analizy wrażliwości. Pracę podsumowują pewne wskazówki dla chirurgów implantujących siatki.
-
Investigation on Filaments for 3D Printing of Nasal Septum Cartilage Implant
PublikacjaSeptoplasty is a widely used method in treating deviated septum. Although it is successfully implemented, there are problems with excessive bleeding, septal perforation, or infections. The use of anatomically shaped implants could help overcome these problems. This paper focuses on assessing the possibility of the usage of a nasal septum cartilage implant 3D printed from various market-available filaments. Five different types...
-
An Integrated Approach to Management of Food Allergy – Recommendations for Consumers and Professionals
Publikacja -
Characteristics of the peanut chain in Europe – implications for peanut allergy
Publikacja -
The microbiome and its impact on food allergy and atopic dermatitis in children
Publikacja -
Możliwości modelowania rozkładu naprężeń i odkształceń w endoprotezie stawu biodrowego w układzie implant - kość z uwzględnieniem własności materiałowych = Possibility of stress and strain modelling in total hip replacement in implant-bone system including material properties
PublikacjaW pracy przedstawiono możliwości wykorzystania numerycznych technik komputerowych do modelowania rozkładu naprężeń i odkształceń w endoprotezie stawu biodrowego w układzie implant-kość z uwzględnieniem własności materiałowych elementów endoprotezy. Przedstawiono komputerowe modele służące do analizy naprężeń i odkształceń w endoprotezie wykonane przy wykorzystaniu metody elementów skończonych. Metody modelowania naprężeń i odkształceń...
-
Experimental Research of Implant-Fascia Connections
PublikacjaW pracy przedstawiono wyniki identyfikacji siły zrywającej połączenie implantu z powięzią wykonane z użyciem różnych typów łączników: zszywek lub szwów chirurgicznych. Rozważono pięć typów łączników i pięć typów implantów.
-
GPU Acceleration of Multilevel Solvers for Analysis of Microwave Components With Finite Element Method
PublikacjaThe letter discusses a fast implementation of the conjugate gradient iterative method with ${rm E}$-field multilevel preconditioner applied to solving real symmetric and sparse systems obtained with vector finite element method. In order to accelerate computations, a graphics processing unit (GPU) was used and significant speed-up (2.61 fold) was achieved comparing to a central processing unit (CPU) based approach. These results...
-
Telemetria odpowiedzi neuronalnych jako metoda wspomagająca dobór parametrów stymulacji przez implant ślimakowy
PublikacjaDzięki pomiarom odpowiedzi neuronalnych i możliwości wyznaczenia na tej podstawie tendencji rozkładu progów stymulacji można lepiej zaprogramować procesor mowy. Jest to niezwykle cenne zwłaszcza u pacjentów nie współpracujących podczas badań (na przykład u małych dzieci). W przypadku takich pacjentów tradycyjne, psychoakustyczne metody doboru parametrów stymulacji przez implant często zawodzą. Natomiast gdy audiolog dysponuje prawdopodobną...
-
[NCh, IMa] Health Effects of Food Components
Kursy Online{mlang pl} Dyscyplina: nauki chemiczne, inżynieria materiałowa Zajęcia fakultatywne dla doktorantów I i II roku Prowadzący: prof. dr hab. inż. Agnieszka Bartoszek-Pączkowska Liczba godzin: 15 Forma zajęć: wykład {mlang} {mlang en} Discipline: chemical sciences, materials engineering Facultative course for 1st and 2nd-year PhD students Academic teachers: prof. dr hab. inż. Agnieszka Bartoszek-Pączkowska Total hours...
-
Dependable Integration of Medical Image Recognition Components
PublikacjaComputer driven medical image recognition may support medical doctors in the diagnosis process, but requires high dependability considering potential consequences of incorrect results. The paper presentsa system that improves dependability of medical image recognition by integration of results from redundant components. The components implement alternative recognition algorithms of diseases in thefield of gastrointestinal endoscopy....
-
Reactions on the surface of the implant under the influence of biofilm
PublikacjaThe contact of a biomaterial with the biological environment in in vitro and in vivo tests leads to the production of a particular ecosystem in which the active roles perform both, the material surface and the extracellular matrix protein forming a biofilm. Proteins affect cell and bacteria adhesion processes, biological activity of cells and activation of inflammatory response.The knowledge of the reaction mechanisms active on...
-
Materials Design for the Titanium Scaffold Based Implant
PublikacjaThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...