Filtry
wszystkich: 23192
-
Katalog
- Publikacje 2002 wyników po odfiltrowaniu
- Czasopisma 24 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Osoby 39 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Kursy Online 45 wyników po odfiltrowaniu
- Wydarzenia 3 wyników po odfiltrowaniu
- Dane Badawcze 21074 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: GREEN SAMPLE PREPARATION
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #7.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #7. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #6.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #6. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #4.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #4. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #9.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #9. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #5.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #5. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #3. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #1. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #8.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #8. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 102 mA. Sample 51, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 102 mA. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 306 mA. Sample 51, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 306 mA. Experiment run #2. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 102 mA. Sample 51, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 102 mA. Experiment run #3. This experiment was preceded by experiment 10.34808/m9mn-yy02. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #3. This experiment was preceded by experiment 10.34808/jf84-x137. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 102 mA. Sample 51, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 102 mA. Experiment run #2. This experiment was preceded by experiment 10.34808/v2hs-b595. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #4.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #4. This experiment was preceded by experiment 10.34808/jf84-x137. The images were taken with thermographic camera VigoCAM V50....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #2. This experiment was preceded by experiment 10.34808/av2f-rb57The images were taken with thermographic camera VigoCAM V50....
-
A universal standard for health-promoting places. Example of assessment -on the basis of a case study of Rahway River Park
PublikacjaThe purpose of this paper is to contribute to development of approaches to the evaluation of the design of public open green spaces (POS). This paper presents a universal standard for the design of health-promoting urban places. The standard is a conceptual framework which was developed after visiting over one hundred public parks and therapeutic gardens in Europe and the United States. The universal standard is a simple and...
-
Meet the Associate Editor
Publikacja -
Facile synthesis of accordion-like porous carbon from waste PET bottles-based MIL-53(Al) and its application for high-performance Zn-ion capacitor
Publikacja -
A COMPREHENSIVE REVIEW OF LIFE CYCLE ASSESSMENT AND ENERGY EFFICIENCY IN 3D PRINTING FOR CONSTRUCTION: CURRENT STATE, BENEFITS, LIMITATIONS, AND FUTURE OUTLOOK
PublikacjaThe agenda of Industry 4.0 strongly affects design and construction at all its phases, and three-Dimensional Printing (3DP) is an essential part of it. The emerging technology has the potential to become a more valid and accepted form of construction. This research is based on a literature review regarding the relationships between the concepts of Life Cycle Assessment (LCA) and energy efficiency for 3DP in construction research...
-
How to evaluate methods used in chemical laboratories in terms of the total chemical risk? – a ChlorTox Scale
PublikacjaReliable assessment of the health and environmental risk associated with the use of chemicals is critical to ob- jectively evaluate the greenness and whiteness of an analytical method. An objective and useful way of risk assessment should take into account all the relevant properties of used substances, their actual amounts needed for application of the method, and quantify the assessment result using a standardized unit. This...
-
CAD Introduction (2023/24)
Kursy OnlineThe course aim is to demonstrate the application of Computer Aided Design in preparation of architectural drawings and project presentations. No previous CAD experience is necessary. Using hands-on exercises, students explore how to create project presentations using 2D drawings and 3D models created in AutoDesk AutoCAD and other programs.
-
Potential of novel atomic emission techniques as a tool for investigation of the possibilities of using industrial waste as additives in construction materials
PublikacjaNowadays, due to the global ecological crisis and ways to prevent a climate disaster, more and more attention is paid to green techno-logies and green Chemistry, which are part of the so-called “The Green Deal.” The main assumption is the optimization of the processes of producing necessary goods and the implementation of methods of managing postproduction waste in the least environmentally harmful manner. In the presented research,...
-
Data from the survey on Gdańsk University of Technology graduates’ competencies assessment by entrepreneurs
Dane BadawczeThe dataset includes data from the survey on the Gdańsk University of Technology (GUT) graduates’ competencies assessment by entrepreneurs. The survey was conducted in 2017. The research sample included 102 respondents representing various firms from Pomeranian Voivodship. The study concerned i.a. assessment of GUT graduates' preparation for the requirements...
-
SEM micrographs of VO2 and V6O13 nanostructures
Dane BadawczeThe DataSet contains the scanning electron microscopy (SEM) micrographs of VO2 and V6O13 thin films deposited on a silicon substrate. The as-prepared thin films were annealing under a reducing atmosphere (94% Ar, 6% H2) at 600 and 700C for 10h.
-
Effect of cooking on the contents of glucosinolates and their degradation products in selected Brassica vegetables
PublikacjaChanges in the levels of glucosinolates and their degradation products in selected Brassica vegetables due to the cooking process were investigated. The purple cauliflower was found to be the best source of aliphatic and indole glucosinolates, and it was also abundant in compounds such as sinigrin, glucoraphanin and glucobrassicin. As a result of cooking rutabaga, green cauliflower and purple cauliflower, a significant decrease...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Terrestrial Survey Images - Multispectral Exterior Model - Gdansk Church Pw. Św. Wojciecha - Micasense Dual
Dane BadawczeDataset description: Raw images from photogrammetric survey. Object: Kościół Rzymskokatolicki Pw. Św. WojciechaLocation: Gdansk, Pomerania, PolandDrone type: N/A (terrestrial images)Flight plan: Free - walk around the object with camera. 3 images taken at the point.Target Product: 3D Model - Multispectral ModelDate: 24.04.2022Direct georeferencing:...
-
Review of the determination of modern used pesticides in water samples
PublikacjaThe increasingly widespread application of pesticides causes that larger amounts of them are entering the environment. Their presence in sources of drinking water, essential to life, is a particular danger. For these reasons it is important to monitor and analyse pesticide residues in the environment. The analysis of environmental samples for the presence of pesticides is very difficult. Firstly, the processes involved in sample...
-
The fast identification of explosives, natcotics and other chemicals carried on board of ships or transported in containers
PublikacjaThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is an advanced technique used in state-of-the art laboratories for fast identification of chemicals. No sample preparation is required, and identification can be carried out through transparent packing, such as plastic or glass,...
-
New trifunctional acrylic water-based paint with self-cleaning, biocidal and magnetic properties
PublikacjaIn the present study, we report the synthesis and application of ZnFe2O4/SiO2-TiO2 nanocomposites with nonstoichiometric content of Fe to Zn used for the first time for the preparation of new generation trifunctional paints with self-cleaning, biocidal and magnetic properties. Currently, there are no compositions on the market for obtaining protective coatings in the form of paint, which simultaneously exhibit biocidal, magnetic...
-
Curing epoxy with ethylenediaminetetraacetic acid (EDTA) surface-functionalized Co Fe3-O4 magnetic nanoparticles
PublikacjaIn this work, the bulk and surface composition of Fe3O4 supermagnetic nanoparticles were modified for efficient epoxy curing. The bare, ethylenediaminetetraacetic acid (EDTA) capped, and cobalt (Co)-doped EDTA capped Fe3O4 nanoparticles were synthesized electrochemically. The crystalline structure and phase information, surface capping, morphology and magnetization behavior of nanoparticles were studied by X-Ray diffraction (XRD),...
-
Enhanced interfacial and mechanical performance of styrene-butadiene rubber/silica composites compatibilized by soybean oil derived silanized plasticization
PublikacjaSilanized plasticizer (SP) was chemically derived and synthesized from soybean oil (SBO) co-vulcanized with bis-(3-(triethoxysilyl)-propyl) tetrasulfide (TESPT) by using the sulfur-accelerated curing system. SP extended styrene-butadiene rubber (SBR)/silica composites have been studied for their improved filler dispersion through coupling interaction at the SBR/silica interface. The effect of SP on cross-link density, thermal,...
-
Zielone stolice Europy
PublikacjaPodsumowanie nowej inicjatywy Unii Europejskiej - ''Zielone Stolice Europy'' (European Green Capital), polegającej na wyróżnieniu miast -liderów we wdrażaniu kompleksowej polityki ochrony środowiska.
-
Diamenty w kolorach fantazyjnych–charakterystyka walorów inwestycyjnych
PublikacjaW artykule scharakteryzowano czynniki determinujące stopę zwrotu z inwestycji w diamenty w kolorach fantazyjnych. Cel opracowania to wskazanie kryteriów, które decydują o przypisaniu do konkretnego diamentu określonej barwy. Ponadto w pracy zbadano, jak barwa, ton oraz nasycenie wpływają na wycenę diamentów w kolorach fantazyjnych. Co więcej, za pomocą regresji hedonicznej zbadano, jak zmieniła się wartość analizowanych kamieni...
-
TG and DTG profiles for plastics: LDPE, HDPE, PP, PD and PET
Dane BadawczeThe dataset includes:
-
XRD patterns of VO2 and V6O13 nanostructures
Dane BadawczeThe DataSet contains the XRD patterns of VO2 and V6O13 thin films deposited on a silicon substrate. The as-prepared thin films were annealing under a reducing atmosphere (94% Ar, 6% H2) at 500, 600 and 700C for 10h.
-
The health impact of urban parks along waterways
PublikacjaWell designed parks along waterways could promote health and well-being of local inhabitants. The way the human settlements meet water bodies can influence the habits of local population. How people spend their time have significant impact on their health. For example, a team of Japanese scientists has proven that a well designed walk-able green spaces are crucial for the longevity of elderly citizens (Takano T. et al, 2002). Nature...
-
COLOUR SYMBOLISM IN FINANCE
PublikacjaColour symbolism plays an important role in everyday life and science. The subject is interdisciplinary and receives significant attention in the literature. It is increasingly entering the field of economics and finance. The authors are the first to research the connotations and symbolism of colours in finance. The following research aims to: identify and determine the meaning of col-ours in connection with the word “finance”,...
-
Evaluation of the Greenness of Analytical Procedures
PublikacjaThis contributions introduces the need to develop the methods to evaluate analytical procedures in the light of green analytical chemistry. Green chemistry metrics are not applicable in analytical chemistry because they refer to the mass of product and no product with mass is generated during analytical determination. Analytical greenness evaluations are based on scoring - such as NEMI or Eco-scale or comparative analysis as it...
-
Nuclear Power
Kursy OnlineNuclear Power is a course for student II degree in full-time studies at Chemistry Faculty, majoring in Green Technology and Monitoring.
-
Application of Electrochemical Impedance Spectroscopy to evaluate cathodically protected coated steel in seawater
PublikacjaTwo types of organic coated carbon steel (S235JR2 grade) electrodes were exposed to artificial seawater environment. One prepared type was defect free while the other one had an intentionally introduced φ0,5 cm coating defect. Both kinds of samples were polarized during the exposure to four potentials corresponding to four different cathodic protection levels. Evolution of their EIS spectra is presented in this paper. Results obtained...
-
Scoring ofsolventsusedinanalyticallaboratoriesbytheirtoxicological and exposurehazards
PublikacjaGreen analyticalchemistry,althoughawellrecognisedconcept,stilllacksreliableenvironmentalimpact assessment procedures.Thisarticledescribesscoringofsolvents,frequentlyusedinanalyticallabora- tories, withCHEMS-1model.Themodelusestoxicologicalandexposuredatatocalculatehazardvalues relatedtotheutilisationofsolvents. The originalmodelwasmodified toincorporatehazardsrelatedtothevolatilityofchemicals.The scoring ofhazardvaluesshowedthatpolarsolventsarelesshazardous.Thescoringresultswereapplied to...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Determination of antifreeze substances in the airport runoff waters by solid-phase microextraction and gas chromatography–mass spectrometry method
PublikacjaA new method has been developed for the determination of antifreeze agents such as ethylene glycol (EG), propylene glycol (PG), and diethylene glycol (DEG) in the samples of airport runoff water. The method is based on headspace solid–phase microextraction (HS–SPME) of target analytes, which is coupled with gas chromatography–mass spectrometry (GC–MS). Until now, there was a lack of appropriate methodology for collecting reliable...
-
Investigation into the Effect of Spinel Pigments on the Photostability and Combustion Properties of Ethylene-Norbornene Copolymer
PublikacjaMulticolor ethylene-norbornene (EN) composites filled with three different spinel pigments (Cobalt Green-PG50, Zinc Iron Yellow-PY 119, Praseodym Yellow-PY159) were prepared by melt mixing and characterized in terms of their stability under destructive environmental conditions. The EN films were subjected to accelerated aging by ultraviolet (UV) photooxidation for 300 h, 600 h, or 900 h. The mechanical performance of the EN composites...
-
Dispersive liquid-liquid microextraction combined with gas chromatography–mass spectrometry for in situ determination of biogenic amines in meat: Estimation of meat's freshness
PublikacjaA dispersive liquid-liquid microextraction (DLLME) gas chromatography–mass spectrometry (GC–MS) technique was developed for the determination of selected biogenic amines (BAs) in samples of poultry, pork and beef. Prior to the extraction process, an appropriate volume of sodium hydroxide solution was added to each of the portioned samples. Next, samples were homogenized, centrifuged and finally sonicated at an increased temperature....