Filtry
wszystkich: 1471
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: RESONANT SENSORS/ACTUATORS
-
Complex Corrosion Monitoring System for Crude Distillation Unit in Form of Neutral Network
PublikacjaComplex and successful corrosion monitoring of refinery processes can significantly reduce material losses and failure risk. The developed corrosion monitoring system is based on online ultrasonic sensors, ER (electrical resistance) probes, gravimetric method and multipoint analytical analysis of chemical composition of the fluids. Additional online LPR (linear polarization resistance) sensors controlling corrosiveness of sour...
-
Optimization of a Fabry-Perot Sensing Interferometer design for an optical fiber sensor of hematocrit level
PublikacjaContinuous measurement of the hemato crit level in blo o d can p otentially b e p erformed using optical bre sensors. The FabryPerot interferometric sensors are a promising candidate in this application. The most imp ortant step in the design of the sensor is design of the sensing interferometer. Adequate cavity length and high interference contrast are two most imp ortant requirements in this application. The design metho d of...
-
Annealing of indium tin oxide (ITO) coated optical fibers for optical and electrochemical sensing purposes
PublikacjaGlass and fiber structures with Indium Tin Oxide (ITO) coating were subjected to annealing in order to identify impact of the thermal treatment on their optical and electrochemical properties. It is shown that the annealing process significantly modifies optical properties and thickness of the films, which are crucial for performance of optical fiber sensors. Moreover, it visibly improves electrochemical activity of ITO on glass...
-
Excitation-independent constant conductance isfet driver
PublikacjaA new constant conductance driver for ISFETs sensors has been developed. The proposed circuit maintains the sensor operating point at constant drain-source conductance. The combination of a simple, self-balancing resistance bridge and the subtraction half (or similar fraction) of source-drain voltage from the gate-source voltage provides the independence of output signal from current and voltage drivers instability. The use of...
-
Investigation of the temperature modulation parameters on semiconductor gas sensor response
PublikacjaIn this work we present the results of the investigation of the sensing properties of semiconductor gas sensors with a sinusoidally modulated temperature in the presence of synthetic air (SA) and three volatile air pollutants, i.e. NH3, NO2 and SO2. The measurements were performed for different average sensor heater temperatures and the amplitude of the modulation signal. In addition, the extraction of features from the sensor...
-
EVALUATION OF THE NO2CONCENTRATION PREDICTION POSSIBILITYBASED ON STATIC AND DYNAMIC RESPONSES OF TGS SENSORSAT CHANGING HUMIDITY LEVELS
PublikacjaThe commercially available metal-oxide TGS sensors are widely used in many applications due to thefact that they are inexpensive and considered to be reliable. However, they are partially selective and theirresponses are influenced by various factors,e.g. temperature or humidity level. Therefore, it is importanttodesign a proper analysis system of the sensor responses. In this paper, the results of examinations of eightcommercial...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublikacjaMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
INFLUENCE OF A VERTEX REMOVING ON THE CONNECTED DOMINATION NUMBER – APPLICATION TO AD-HOC WIRELESS NETWORKS
PublikacjaA minimum connected dominating set (MCDS) can be used as virtual backbone in ad-hoc wireless networks for efficient routing and broadcasting tasks. To find the MCDS is an NP- complete problem even in unit disk graphs. Many suboptimal algorithms are reported in the literature to find the MCDS using local information instead to use global network knowledge, achieving an important reduction in complexity. Since a wireless network...
-
Structural Health Monitoring of Overhead Power Transmission Lines
PublikacjaStructural Health Monitoring (SHM) is a novel and continuously developing branch of science and technology that draws attention of scientists all over the world. It creates opportunities to detect, localize and identify structural damage of various types such as: line breakage, permissible sag, bolt loosening, fatigue cracking or insulator contamination. On the other hand the methods used to estimate the remaining operational...
-
Mathematical Modelling in Diagnosis of Wastewater Treatment Plant
PublikacjaThe paper reports development of mathematical modeling in diagnosis of the WWTP. The algorithm is based on a comparition of data from the mathematical modeling and measurments of real datefrom WWTP, until it will detect any malfunction of the sensors in th case of study.
-
Identyfikacja trajektorii obiektów dynamicznych w przestrzeni kartezjańskiej na podstawie informacji z wielu estymatorów stanu
PublikacjaW rozprawie przedstawiono metodologię umożliwiającą implementację rozproszonego asynchronicznego systemu wyznaczania trajektorii. System tego typu jest złożony ze zbioru tzw. węzłów (estymatorów lokalnych), które komunikują się ze sobą. Każdy węzeł wyznacza trajektorię obserwowanego obiektu/procesu na podstawie dwóch zbiorów danych. Pierwszym zbiorem są pomiary dostarczane przez skojarzone z danym...
-
Piezoelectric Transducer for Mechanical Assessment of Soft Tissues. Concept, Implementation and Analysis
PublikacjaThe main goal of this work was following: preparation of a new concept, implementation and analysis of the piezoelectric resonant sensor/actuator for measuring the aging process of human skin. The research work has been carried out in the framework of cooperation between the INP-ENSEEIHT-LAPLACE, Toulouse, France, and at the Gdansk University of Technology, Faculty of Electrical and Control Engineering, Research Group of...
-
Anna Danuta Dettlaff dr inż.
OsobyTytuł magistra inżyniera uzyskała z wyróżnieniem w 2013 roku w Wydziale Chemii Analitycznej. W latach 2013-2017 była doktorantką na kierunku Technologia Chemiczna, podczas których zajmowała się pracą pt. "Badania nad nanokompozytami bazującymi na polimerach przewodzących oraz materiałach węglowych w celu zastosowania ich w superkondensatorach". W 2015 roku odbyła trzymiesięczny staż naukowy w Oldenburgu w Niemczech. Stopień doktora...
-
Application of BAN Network to Increase Security in Transport Systems
PublikacjaIn the article general characteristics of the BAN network with M2M communications are presented. These are networks that enable the implementation of wireless transmission of signals using special sensors located on the body or implanted subcutaneously. These sensors allow monitoring of different type life parameters of a human. In the next part of work there is proposed the implementation of BAN networks to transport systems as...
-
Propagation Loss and Interference Analysis for 5G Systems in the Context of C-ITS System Implementation
PublikacjaThe article presents the concept of implementing subsequent phases of services for the C-ITS system (the Cooperative Intelligent Transport Systems), based on the European Parliament resolution of March 2018. Next, the 5G systems, in the context of their possible cooperation with C-ITS systems, were discussed. Numerical propagation analysis was performed for V2V and V2I type communication based on two different propagation models....
-
A Substrate Integrated Waveguide (SIW) Bandpass Filter in A Box Configuration With Frequency-Dependent Coupling
PublikacjaThis letter presents the design of a microwave bandpass filter with frequency-dependent coupling implemented in substrate integrated waveguide (SIW) technology. The proposed filter implements a four-pole generalized Chebyshev filtering function with two transmission zeros. Resonators are arranged in an extended box configuration with dispersive coupling on a main signal path, which produces an extra zero in comparison to classical...
-
Adaptive estimation of the transformer stray capacitances for DC–DC converter modelling
PublikacjaNew low cost and accurate estimation method of transformer stray capacitances for wide band DC–DC converter modelling and design is proposed. The Wiener filter (WF) method is applied to estimate the transformer impedance – referred to the selected transformer winding configurations. Laboratory tests are used to adapt the filter, that is to find optimal impedance which minimises mean square error between measured, noise perturbed...
-
Zirconia-based mixed potential sensor with Pt electrode prepared by spin-coating of polymeric precursor
PublikacjaMany types of yttria-stabilized zirconia (YSZ) based gas sensors have been explored extensively in recent years. Great attention have been directed to mixed-potential-type gas sensors. It is due to growing concerns with environmental issues. Not without a significance is the fact of very attractive performance of this type of sensor allowing to detect low concentration of pollutant gases. In this paper two types of YSZ based mixed-potential...
-
Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Long-term measurement of physiological parameters - adult (120 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters.
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (60 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 6th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 5 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 12. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (4h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 11. series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 2 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 7th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 10th series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (150 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 150 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (13h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (13 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 9th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 4 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 8th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (10h)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (10 hours) measurement of physiological parameters was performed on the healthy volunteer...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 3 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Analysis of Properties of an Active Linear Gesture Sensor
PublikacjaBasic gesture sensors can play a significant role as input units in mobile smart devices. However, they have to handle a wide variety of gestures while preserving the advantages of basic sensors. In this paper a user-determined approach to the design of a sparse optical gesture sensor is proposed. The statistical research on a study group of individuals includes the measurement of user-related parameters like the speed of a performed...
-
A modern approach to an unmanned vehicle navigation
PublikacjaA traditional approach to manned vehicles navigation uses a data combined form a variety of navigation sensors like satellite, inertial and time-of-flight. With support of operators perception, chart and sensor, data are analyzed and navigation decisions are made. An unmanned platforms navigation needs an operators support, who is supervising a platforms decision process, basing on navigation data obtained via variety of electronic...
-
Hydrographic Multisensory Unmanned Watercraft
PublikacjaThis article describes the design of the unmanned surface vessel (USV) and the algorithms for planning the trajectories to be followed on measurement missions. The algorithms take account of the dynamically varying impacts of external forces (wind and surface current) on the vessel's motion. Feedback loops enable the counteraction of external factors that cause disturbance to the desired trajectory. The sensors installed on the...