wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: layer-by-layer
-
A novel genetic approach to provide differentiated levels of service resilience in IP-MPLS/WDM networks
PublikacjaThis paper introduces a novel class-based method of survivable routing for connection-oriented IP-MPLS/WDM networks, called MLS-GEN-H. The algorithm is designed to provide differentiated levels of service survivability in order to respond to varying requirements of end-users. It divides the complex problem of survivable routing in IP-MPLS/WDM networks into two subproblems, one for each network layer, which enables finding the...
-
Tribological model of porous bearings with particular attention given to the lubricant lubricity
PublikacjaThe friction and wear problems, accompanying all the tribological systems, lead to reduced service life. In order to prevent such situation, it is necessary to maintain fluid friction, which improves durability of all friction nodes in a tribological system. In the paper, the tribological system consists of porous bearings and the model deals with their weakest spots - the oil outflow points in the porous wall. A kinetic model...
-
Ceria Based Protective Coatings for Steel Interconnects Prepared by Spray Pyrolysis
PublikacjaStainless steels can be used in solid oxide fuel/electrolysis stacks as interconnects. For successful long term operation they require protective coatings, that lower the corrosion rate and block chemical reactions between the interconnect and adjacent layers of the oxygen or the hydrogen electrode. One of the promising coating materials for the hydrogen side is ceria. Using standard sintering techniques, ceria sinters at around...
-
THERMAL ANALYSIS AND DESIGN OF HYBRID MICROCHANNEL-MICROJET TEST PROBE
PublikacjaThe paper presents the numerical investigation of a microjet- microchannel cooling module. In which microjets of water are impinging into the microchannels and forming a liquid film on the impingement surface. Applied technology takes benefits from two very attractive heat removal techniques. When lminar jets are impinging on the surface have a very high kinetic energy at the stagnation point, also in microchannels boundary layer...
-
Short Term Monitor of Photodegradation Processes in Ranitidine Hydrochloride Observed by FTIR and ATR FTIR
PublikacjaThe effects of degradation of ranitidine hydrochloride exposed to UVB radiation (l = 310 nm) and oxygen in a weathering chamber were studied by Fourier Transform Infrared spectroscopy (FTIR) and Attenuated Total Reflectance Fourier Transform Infrared spectroscopy (ATR-FTIR). ATR-FTIR profile indicated that the degradation was spatially heterogeneous. Significant amounts of photoproducts were detected only in a directly...
-
High temperature drying of beech with content of tension wood
PublikacjaThe presented artcle is focused on comparison of tension and normal wood of beech (Fagus sylvatica L.) in a high-temperature drying process. Samples of 26 mm thickness were selected from sapwood zone with different angle of growth rings. The article evaluated properties of tension and normal wood before and after drying process. Properties which are monitored were moisture, moisture gradients, covering tests, colour changes and...
-
Clustering Context Items into User Trust Levels
PublikacjaAn innovative trust-based security model for Internet systems is proposed. The TCoRBAC model operates on user profiles built on the history of user with system interaction in conjunction with multi-dimensional context information. There is proposed a method of transforming the high number of possible context value variants into several user trust levels. The transformation implements Hierarchical Agglomerative Clustering strategy....
-
Monitoring system of the road embankment
PublikacjaThe paper presents the monitoring system of the embankment supported on concrete columns and overlaid by a load transfer platform (LTP) with the embedded steel grid. This field investigation was to study the complex inter-action between the columns, the LTP layer, and steel reinforcement via full-scale in situ measurements during erection of the embankment. The study was focused on the behaviour of steel reinforcement and the behaviour...
-
Instrumented End Notched Flexure - Crack propagation and process zonemonitoring. Part I: Modelling and analysis
PublikacjaAnalysis of the three-point bending, End Notched Flexure (ENF), test is presented for exploitation with a new experimental methodology using the backface strain monitoring technique. The model consists oftwo Timoshenko beams joined with a two parameter elastic foundation, to evaluate stress and strain fields in both adherends and the adhesive layer, together with the specimen compliance and energyrelease rate. This model is compared...
-
Optimized Stress and Geometry Control of Spherical structures under Lateral Loadings
PublikacjaIn this paper, a numerical model of a double-layer spherical structure has been examined under lateral loadings. When the structure has been distorted due to loadings, the dislocated joints have been moved to their original positions utilizing the adjustment techniques based on the force method. Meanwhile, the members’ internal forces were kept in the desired domain. Optimization techniques were also implemented in order to minimalize...
-
Tribological Properties of Thermoplastic Materials Formed by 3D Printing by FDM Process
PublikacjaThe dataset entitled 3D printed ABS thermoplastic vs. steel. Dry sliding wear test in constant load & velocity ring on flat configuration. Test parameters: print layer thickness and orientation. Test symbol: 019_h_4 contains: the time base (expressed in seconds and minutes), the friction torque for sliding friction, rotational velocity of the counter – specimen (velocity of sliding), friction coefficient, load in the friction contact...
-
Analytical fluctuation enhanced sensing by resistive gas sensors
PublikacjaResistance fluctuations across polarised resistive gas sensors were studied in detail to evaluate sensor working conditions for detecting methane and ammonia at various concentrations. The 1/f noise component typically dominates other noise sources up to a few kHz and can be utilised to improve gas selectivity when compared with measurements of the sensor DC resistance. The Arrhenius plot was created and the activation energy for...
-
Compressible gas density measurement by means of Fourier analysis of interferograms
PublikacjaThis paper describes a method for nonintrusive compressible gas density measurement by means of automated analysis of interferograms using FFT (Fast Fourier Transform), and its implementation using DFT (Discrete Fourier Transform), that does make this measurement technique a fairly valuable and accessible experimental method. The presented approach makes it possible to use the finite fringe setting of the interferometer, thus reducing...
-
Low-Loss Mechanically Tunable Resonator and Phase Shifters in Groove Gap Waveguide Technology
PublikacjaThis research is focused on the design and realization of high-performance high-power variable phase shifters in groove gap waveguide technology. Specifically, it is shown that the unique characteristic of groove gap waveguides, which is its proper operation without the need for electrical connection between the top and bottom sections of the waveguide, can be used to design mechanically tunable devices. Using the proposed method,...
-
Adjusted SpikeProp algorithm for recurrent spiking neural networks with LIF neurons
PublikacjaA problem related to the development of a supervised learning method for recurrent spiking neural networks is addressed in the paper. The widely used Leaky-Integrate-and-Fire model has been adopted as a spike neuron model. The proposed method is based on a known SpikeProp algorithm. In detail, the developed method enables gradient descent learning of recurrent or multi-layer feedforward spiking neural networks. The research included...
-
Performance and Security Testing for Improving Quality of Distributed Applications Working in Public/Private Network Environments
PublikacjaThe goal of this dissertation is to create an integrated testing approach to distributed applications, combining both security and performance testing methodologies, allowing computer scientist to achieve appropriate balance between security and performance charakterstics from application requirements point of view. The constructed method: Multidimensional Approach to Quality Analysis (MA2QA) allows researcher to represent software...
-
Seborrhoeic keratosis - Male, 50 - Tissue image [71307295885421]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 76 - Tissue image [7260729594497751]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Male, 45 - Tissue image [7130729588547541]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hemangioma, NOS - Male, 53 - Tissue image [6210729587596471]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Male, 61 - Tissue image [726072959449161]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 61 - Tissue image [7130729588546351]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 53 - Tissue image [7270729584627781]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Male, 69 - Tissue image [7260729594492821]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Warthin tumor - Male, 67 - Tissue image [8020729577652261]
Dane BadawczeThis is the histopathological image of PAROTID GLANID tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Male, 64 - Tissue image [6210729587597051]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 73 - Tissue image [7260729594495211]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 53 - Tissue image [7270729584624491]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adenocarcinoma, usual type - Male, 55 - Tissue image [7040247104946181]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Adenocarcinoma, usual type - Male, 55 - Tissue image [5310730015839711]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Warthin tumor - Male, 67 - Tissue image [8020729577659131]
Dane BadawczeThis is the histopathological image of PAROTID GLANID tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 74 - Tissue image [7130729588544901]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Epidermal cyst - Male, 43 - Tissue image [8020729577654721]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hemangioma, NOS - Male, 45 - Tissue image [6210729587599851]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Male, 56 - Tissue image [7130729588545551]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 62 - Tissue image [7260729594493721]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 45 - Tissue image [7130729588545631]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adenocarcinoma, usual type - Male, 55 - Tissue image [5310730015833241]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Dermatofibroma, NOS - Female, 43 - Tissue image [8020729577651431]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 53 - Tissue image [7270729584629261]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Male, 61 - Tissue image [7260729594498051]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 52 - Tissue image [8140730001728421]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 67 - Tissue image [7130729588545641]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 38 - Tissue image [8170729597196941]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Male, 69 - Tissue image [7130729588546971]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hemangioma, NOS - Female, 59 - Tissue image [8130730003081321]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Warthin tumor - Female, 72 - Tissue image [8020729577643991]
Dane BadawczeThis is the histopathological image of PAROTID GLANID tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Male, 63 - Tissue image [8140730001722511]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Seborrhoeic keratosis - Female, 32 - Tissue image [7130729588542301]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tubular adenocarcinoma - Female, 53 - Tissue image [7270729584629601]
Dane BadawczeThis is the histopathological image of COLON tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.