Wyniki wyszukiwania dla: E-NOSE
-
Application of Electronic Nose Based on Fast GC for Authenticity Assessment of Polish Homemade Liqueurs Called Nalewka
PublikacjaThe possibility of application of electronic nose based on fast GC for differentiation of three types of cherry liqueurs, namely Polish homemade liqueurs called nalewka, commercially available liqueurs labeled as nalewka, and commercial liqueurs, was investigated. This device was equipped with two parallel connected columns with different stationary phases coupled to two ultrasensitive flame ionization detectors (μ-FIDs). Four...
-
Evaluation of the suitability of electronic nose based on fast GC for distinguishing between the plum spirits of different geographical origins
PublikacjaPlum spirits are obtained exclusively via the alcoholic fermentation and distillation of meaty plums or must composed of plums, with or without stones. The European countries such as Poland, the Slovak Republic, the Czech Republic, Bulgaria and Romania are the leading producers of this alcoholic beverage. Information about the authentication of plum spirits produced in different countries can be found in the published literature....
-
Monitoring of odour nuisance in the Tricity Agglomeration
PublikacjaThe paper describes a principle of operation of odour nuisance monitoring network, which is being designed in the Tricity Agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The...
-
Prediction of the Biogenic Amines Index of Poultry Meat Using an Electronic Nose
PublikacjaThe biogenic amines index of fresh chicken meat samples during refrigerated storage was predicted based on the headspace analysis using an electronic nose equipped with an array of electrochemical sensors. The reference biogenic amines index values were obtained using dispersive liquid–liquid microextraction–gas chromatography–mass spectrometry. A prototype electronic nose with modular construction and a dedicated sample chamber...
-
Quality Evaluation of Agricultural Distillates Using an Electronic Nose
PublikacjaThe paper presents the application of an electronic nose instrument to fast evaluation of agricultural distillates differing in quality. The investigations were carried out using a prototype of electronic nose equipped with a set of six semiconductor sensors by FIGARO Co., an electronic circuit converting signal into digital form and a set of thermostats able to provide gradient temperature characteristics to a gas mixture. A volatile fraction...
-
Differentiation Between Spirits According to Their Botanical Origin
PublikacjaAgricultural distillates are used for the production of spirit beverages. As more and more products with a specific botanical composition specified on the label are produced (e.g. rye vodkas, wheat vodkas and Polish Vodka, which cannot be produced with the addition of maize distillate), it is necessary to look for quicker and more accurate methods allowing the determination of botanical origin of alcoholic beverages and materials...
-
Application of electronic nose based on fast GC for comparison of aroma profiles of homemade cherry "Nalewka" made with addition of different amount of sugar
PublikacjaNalewka is a traditional Polish homemade spirit beverage and there are many different recepies for the production of nalewkas. However, it is not knownwhat amount of sugar can have influence of their aroma profiles. There is little information on the comparison of aroma profiles of Polish cherry nalewkas made with addition of different amount of sugar. For this purpose electronic nose based on fast GC has been used. Electronic...
-
Application of electronic nose based on fast GC for comparison of aroma profiles of homemade cherry "Nalewka" made with addition of different amount of sugar
PublikacjaNalewka is a traditional Polish homemade spirit beverage and there are many different recepies for the production of nalewkas. However, it is not knownwhat amount of sugar can have influence of their aroma profiles. There is little information on the comparison of aroma profiles of Polish cherry nalewkas made with addition of different amount of sugar. For this purpose electronic nose based on fast GC has been used. Electronic...
-
Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks
PublikacjaThis paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills and sewage treatment plants were subjected...
-
Prospects of ionic liquids application in electronic and bioelectronic nose instruments
PublikacjaThis paper addresses the problem of application of ionic liquids to chemical sensors and biosensors being an integral part of the electronic and bioelectronic-type instruments. The design and principle of operation of the electronic and bioelectronic noses are compared. Both the benefits and shortcomings of the application of ionic liquids in these type of instruments are described. The prospects of the development and application...
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublikacjaMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublikacjaThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
Chemiresistive gas sensors based on carbon nanotubes - fabrication and application
PublikacjaMany types of sensors have been invented to identify and quantify chemical contamination in the gas phase. Sensors based on carbon nanotubes are particularly attractive because of their wide range of applicaions and potential use in electronic nose that can be controlled using algorithms of Artificial Intelligence. Sensor functions, fabrication and selected applications are reviewed and discussed with focus on chemiresistors. Drawbacks...
-
PTR-MS and electronic nose application for volatile fraction analysis of cigar tobacco
PublikacjaCigar consumers attach great importance to the quality of these products. At the same time, cigars are often expensive, so destructive analytical methods of quality control are not being desired. However, it has been found that there are many volatile organic compounds in their headspace. Because of that, proton transfer reaction–mass spectrometry and electronic nose were used to analyse it. The obtained results were used to distinguish...
-
Maxillary sinus aeration analysis using computational fluid dynamics
PublikacjaThe maxillary sinus aeration using the computational fluid dynamics (CFD) method based on individual adult patients’ computed tomography (CT) scans were analyzed. The analysis was based on CT images of 4 patients: one with normal nose anatomy and three with nasal septal deviation (NSD) and concha bullosa (CB). The CFD simulation was performed using the Reynolds-Average Simulation approach and turbulence closure based on linear...
-
Application of electronic nose to effectiveness monitoring of air contaminated with toluene vapors biofiltration process
PublikacjaThe research presents the application of electronic nose (combined with MLR model) to on-line effectiveness monitoring of biofiltration of air contaminated with hydrophobic, odorous compound (toluene vapors). The research was conducted using two-section biotrickling filter inhabited by Candida environmental isolates. Gas chromatography was used as the comparative technique to obtain reliable quantification of toluene concentration...
-
Distinction of citrus fruits based on their volatile composition using the electronic nose
PublikacjaThe aim of the study was to analyze the volatile fraction of the citrus fruit using an electronic nose device integrated with ultrafast gas chromatography. The subjects were Citrus aurantifolia, Fortunella margarita Swingle and Citrus × floridana. The chromatographic data obtained were analyzed by means of chemometric methods: PCA and SQC. On the basis of the charts obtained, it is possible to distinguish the fruits tested on the...
-
Electronic Noses and Electronic Tongues
PublikacjaChapter 7 reports the achievements on the field of artificial senses, such as electronic nose and electronic tongue. It examines multivariate data processing methods and demonstrates a promising potential for rapid routine analysis. Main attention is focused on detailed description of sensor used, construction and principle of operation of these systems. A brief review about the progress in the field of artificial senses and future trends...
-
Application of the Electronic Nose Technique to Differentiation between Model Mixtures with COPD Markers
PublikacjaABSTRACT The paper presents the potential of an electronic nose technique in the field of fast diagnostics of patients suspected of Chronic Obstructive Pulmonary Disease (COPD). The investigations were performed using a simple electronic nose prototype equipped with a set of six semiconductor sensors manufactured by FIGARO Co. They were aimed at verification of a possibility of differentiation between model reference mixtures with...
-
Real-time facial feature tracking in poor quality thermal imagery
PublikacjaRecently, facial feature tracking systems have become more and more popular because of many possible use cases. Especially in medical applications location of the face and facial features are very useful. Many researches have presented methods to detect and track facial features in visible light. However, facial feature analysis in thermography may also be very advantageous. Some examples of using infrared imagery in medicine include...
-
Hidrocystoma - Male, 81 - Tissue image [6300730028273771]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fibrolipoma - Female, 59 - Tissue image [6300730028279541]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Sebaceoma - Male, 80 - Tissue image [6260730021895581]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Investigations on the removal of hydrophobic odorous volatile organic compounds by biotrickling filtration monitored with electronic nose
PublikacjaThe presented paper presents the results of research on the removal of selected hydrophobic volatile organic compounds (VOCs) from their mixture with air by means of a trickled-bed biofiltration. The efficiency of the removal of toluene and α-pinene, as model VOCs, in a three-section biotrickling filter is evaluated using GCFID and additionally monitored with an electronic nose. The results show that the removal of the model mixture...
-
Trichoepithelioma - Male, 73 - Tissue image [6260730021899091]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Trichoblastoma - Female, 69 - Tissue image [6300730028256151]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Trichoepithelioma - Female, 62 - Tissue image [6300730028262371]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cylindroma of skin - Female, 65 - Tissue image [6300730028245731]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Trichoepithelioma - Female, 62 - Tissue image [6130730026869121]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Ameloblastoma, NOS - Female, 78 - Tissue image [53007300258751]
Dane BadawczeThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Ameloblastoma, NOS - Female, 78 - Tissue image [5300730025872991]
Dane BadawczeThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Male, 43 - Tissue image [619073001732461]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Ameloblastoma, NOS - Female, 78 - Tissue image [530073002587891]
Dane BadawczeThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Male, 43 - Tissue image [6190730017322071]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cylindroma of skin - Female, 65 - Tissue image [6300730028242981]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Ameloblastoma, NOS - Female, 78 - Tissue image [5300730025872211]
Dane BadawczeThis is the histopathological image of OTHER AND ILL-DEFINED SITES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Trichoepithelioma - Male, 34 - Tissue image [6190730017322711]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublikacjaThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Monitoring and efficiency assessment of biofilter air deodorization using electronic nose prototype
PublikacjaBiofiltration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype for monitoring and efficiency assessment of air biofiltration. The study was conducted using model gas mixtures containing representatives of three groups of chemical compounds: n-hexane...
-
Trichofolliculoma - Male, 72 - Tissue image [6250730010621101]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intradermal nevus - Female, 58 - Tissue image [630073002827471]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Basal cell carcinoma, NOS - Male, 41 - Tissue image [6200730021565361]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intradermal nevus - Female, 71 - Tissue image [6300730028276001]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma in situ, NOS - Female, 65 - Tissue image [6260730021896921]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Trichofolliculoma - Male, 72 - Tissue image [625073001062151]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Trichofolliculoma - Male, 72 - Tissue image [6250730010628511]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Gas sampling system for matrix of semiconductor gas sensors
PublikacjaSemiconductor gas sensors are popular commercial sensors applied in numerous gas detection systems. They are reliable, small, rugged and inexpensive. However, there are a few problem limiting the wider use of such sensors. Semiconductor gas sensor usually exhibits a low selectivity, low repeatability, drift of response, strong temperature and moisture influence on sensor properties. Sample flow rate is one of the parameters that...
-
Basal cell carcinoma, NOS - Female, 72 - Tissue image [3140630024308061]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Basal cell carcinoma, NOS - Female, 72 - Tissue image [3140630024309911]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma, keratinizing, NOS - Male, 76 - Tissue image [6300730028279071]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.