Wyniki wyszukiwania dla: fiber-optic
-
Diamond Structures for Tuning of the Finesse Coefficient of Photonic Devices
PublikacjaFinesse coefficient is one of the most important parameters describing the properties of a resonant cavity. In this research, a mathematical investigation of the application of diamond structures in a fiber-optic Fabry–Perot measurement head to assess their impact on the finesse coefficient is proposed. We present modeled transmission functions of cavities utilizing a nitrogen-doped diamond, a boron-doped diamond, nanocrystalline...
-
Optical-Fiber Microsphere-Based Temperature Sensors with ZnO ALD Coating—Comparative Study
PublikacjaThis study presents the microsphere-based fiber-optic sensor with the ZnO Atomic Layer Deposition coating thickness of 100 nm and 200 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range from 100 °C to 300 °C, with a 10 °C step. The interferometric signal was used to monitor the integrity of the microsphere and its attachment to the connecting fiber. For the sensor...
-
Microsphere structure application for supercapacitor in situ temperature monitoring
PublikacjaConstant, real-time temperature monitoring of the supercapacitors for efficient energy usage is in high demand and seems to be crucial for further development of those elements. A fiber-optic sensor can be an effective optoelectronic device dedicated for in-situ temperature monitoring of supercapacitors. In this work, the application of the fiber-optic microstrucutre with thin zinc oxide (ZnO) coating fabricated in the atomic layer...
-
Distance measurement by the low coherent interferometer
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications
PublikacjaStarting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Niskokoherencyjne czujniki światłowodowe wykorzystujące cienkowarstwowe struktury nanodiamentowe
PublikacjaZnaczny rozwój technologii wytwarzania czujników światłowodowych spowodował, że są one powszechnie dostępne i stosowane w wielu gałęziach przemysłu, nauki oraz medycyny. Zastosowanie nowych materiałów w konstrukcji takich czujników niesie za sobą duży potencjał. Celem rozprawy jest przedstawienie możliwości wykorzystania cienkowarstwowych struktur nanodiamentowych w niskokoherencyjnych czujnikach światłowodowych, które poprawią...
-
Emission spectra of UV and fluorescent lamps
Dane BadawczeData contain emision spectra of two different UV lamps: Special "TL"E 22W/10 Black light (Philips) and Semilac UV, 36 W and also Fluorescent lamp: L22W/840 Circular Cool White, Lumilux (Osram). These spectra were recorded by USB4000 Fiber Optic Spectrometer.
-
Coupled nonlinear Schrödinger equations in optic fibers theory
PublikacjaIn this paper a detailed derivation and numerical solutions of CoupledNonlinear Schr¨odinger Equations for pulses of polarized electromagnetic wavesin cylindrical fibers has been reviewed. Our recent work has been compared withsome previous ones and the advantage of our new approach over other methods hasbeen assessed. The novelty of our approach lies is an attempt to proceed withoutloss of information within the frame of basic...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublikacjaIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Low-Coherence Interferometer with Nanocrystalline Diamond Films with Potential Application to Measure Small Biological Samples
PublikacjaThe study investigates a case of a low-coherence fiber-optic Fabry–Prerot interferometer with a nanocrystalline diamond (NCD) mirror. The method of achieving double density of interference fringes is proposed by the application of birefringent material in the cavity of the interferometer. It can be used to reduce sample volume in comparison to conventional interferometers. The use of a biocompatible diamond mirror makes it specifically...
-
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Dane BadawczePresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Experimental data of galvanic electric cells measurements
Dane BadawczeInternal temperature of an electric cell can be measured and monitored using microsphere-based fiber-optic sensors with thin ALD ZnO coating. Their compact size will allow to integrate them easily and effectively within the electric cells. Utilization of presented sensors allows to detect, in real time, damages to the structure of the sensor head that...
-
Communication Networks in the Service of the Environmental Monitoring
PublikacjaIn the paper selected issues relating to communication networks in the services of the environmental monitoring (EM) have been described. It is divided into three main parts: introduction, wire and wireless networks. At the beginning of the basic definitions were explained. The wire part focuses on a plain old telephone service (POTS), an integrated services digital network (ISDN), a digital subscriber line (DSL) and a fiber-optic...
-
Measurements of the optical and thermal properties of the 2D black phosphorus coating
PublikacjaBlack phosphorus is a 2D material, which properties are still being discovered. In this paper, the sensitivity to the temperature of a few-layer black phosphorus coating deposited, on the surface of a microsphere-based fiber-optic sensor, by a dip-coating method is presented. The coating was investigated after 2, 3, and 5 deposition cycles and during temperature growth from 50 °C to 300 °C in an interferometric setup. The intensity...
-
Impact of temperature on optical sensing in biology based on investigation of SARS‐CoV ‐2
PublikacjaIn this paper, we present an investigation of the influence of the temperature on the sensing of biological samples. We used biofunctionalized microsphere-based fiber-optic sensor to detect immunoglobulin G attached to the sensor head at temperatures relevant in biological research: 5°C, 25°C, and 55°C. The construction of the sensor allowed us to perform measurements in the small amount of solution. The results of our experiment...
-
Nitrogen-Doped Diamond Film for Optical Investigation of Hemoglobin Concentration
PublikacjaIn this work we present the fabrication and characterization of a diamond film which can be utilized in the construction of optical sensors for the investigation of biological samples. We produced a nitrogen-doped diamond (NDD) film using a microwave plasma enhanced chemical vapor deposition (MWPECVD) system. The NDD film was investigated with the use of scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman...
-
Investigation of H2:CH4 plasma composition by means of spatially resolved optical spectroscopy
PublikacjaThe system based on spatially resolved optical emission spectroscopy dedicated for in situ diagnostics of plasma assisted CVD processes is presented in this paper. Measurement system coupled with chemical vapour deposition chamber by dedicated fiber-optic paths enables investigation of spatial distribution of species densities (Hx, H+, CH, CH+) during chemical vapour deposition process. Experiments were performed for a various...
-
Spectral reflectance and transmission modeling of multi-cavity Fabry-Pérot interferometer with ZnO thin films
PublikacjaIn this paper spectral reflectance and transmission of a low-coherence fiber-optic Fabry-Pérot interferometer with thin ZnO layers is analyzed using a multi-cavity approach. In the investigated setup two standard single-mode optical fibers (SMF-28) with thin ZnO films deposited on their end-faces form an extrinsic Fabry-Pérot interferometer with air cavity. Calculations of the spectral response of the interferometer were performed...
-
Stability of thin film diamond mirror for applications in interferometers under the short-time exposure on selected aggressive chemicals
PublikacjaIn presented study a thin boron-doped diamond film was proposed for application in the interferometry as a highly durable optical mirror. The unique properties of the diamond films, like high chemical stability and hardness, allow them to be used even in the chemically aggressive environment, where the commonly used silver mirrors can be susceptible to damage. The investigated nanodiamond layer was fabricated by uPE CVD method...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
5G/6G optical fronthaul modeling: cost and energy consumption assessment
PublikacjaIn fifth generation (5G) and the future beyond 5G (6G) radio access networks (RANs), the cost of fronthaul deployment is a main challenge for mobile network operators. Depending on different constraints, there are various solutions to deploy an efficient fronthaul. Fiber-optic-based fronthaul offers long-term support with regard to a rapid increase in capacity demands. When fiber connections, either point-to-point (P2P) or point-to-multipoint...
-
Tuning of the finesse coefficient of optoelectronic devices
PublikacjaOptoelectronic devices attracted considerable attention in many branches of science and technology, which can be attributed to their unique properties. Many of them use optical cavities which parameters can be adopted to specific requirements. This thesis investigates the introduction of diamond structures (nitrogen-doped diamond film, boron-doped diamond film, undoped diamond sheet) to optical cavities to tune their finesse coefficient....
-
Low-coherence method of hematocrit measurement
PublikacjaDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
Effects of laser pulse duration in two-photon vision threshold measurements
PublikacjaPulsed near-infrared (NIR) light sources can be successfully applied for both imaging and functional testing of the human eye, as published recently1. These two groups of applications have different requirements. For imaging applications, the most preferable is invisible scanning beam while efficiently visible stimulating beam is preferable for functional testing applications. The functional testing of human eye using NIR laser...
-
Incorporation of nitrogen in diamond films – A new way of tuning parameters for optical passive elements
PublikacjaThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM), confocal...
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048224001]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048226731]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048221721]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048221281]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048223771]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Incorporation of nitrogen in diamond films - A new way of tuning parameters for optical passive elements
PublikacjaThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy...
-
Problems of Measuring Gas Content in Oil in a Two-Phase Flow: A Review
PublikacjaIn view of the necessity of measuring the air content in oil in two-phase flows in the context of general industry, a review of the most popular methods of measuring the air content in oil was carried out. This review includes an assessment of their advantages and disadvantages and of whether they meet criteria such as the degree of filling, the size and number of bubbles, verification, the absence of additional pressure drops,...
-
Bearing capacity of monotonically installed tapered piles in medium dense Fontainebleau sand
PublikacjaA series of installation of tapered piles in medium-dense Fontainebleau sand were performed in the geotechnical centrifuge at Gustave Eiffel University. The models of piles with three different shapes - straight profile (S), and with taper angle of 0.70 degrees (T1), and 1.4 degrees (T2) were used. The piles were instrumented with fiber optic wires on the shaft and load cell at the base. After monotonic installation, the models were...
-
Cytomegaloviral disease, unspecified - Male, 50 - Tissue image [10110730048229011]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Investigation of the Few‐Layer Black Phosphorus Degradation by the Photonic Measurements
PublikacjaFew-layer black phosphorus (FLBP) is a 2D material that gains worldwide interest for its possible applications, mainly in electronics and optoelec-tronics. However, as FLBP is prone to a degradation process under envi-ronmental conditions, there is a need for a monitoring method allowing investigation of its surface quality. Among many techniques, optoelectronic ones have unique advantages of fast response, non-contact, and non-invasive...
-
A new approach to design of weather disruption-tolerant wireless mesh networks
PublikacjaWireless Mesh Networks, offering transmission rates of 1–10 Gb/s per a millimeter-wave link (utilizing the 71–86 GHz band) seem to be a promising alternative to fiber optic backbone metropolitan area networks because of significantly lower costs of deployment and maintenance. However, despite providing high transmission rates in good weather conditions, high-frequency wireless links are very susceptible to weather disruptions....
-
Adam Władziński
OsobyAdam Władziński, doktorant na Politechnice Gdańskiej, specjalizuje się w inżynierii biomedycznej, skupiając się na uczeniu maszynowym do przetwarzania obrazów z druku 3D układów pomiarowych i tkanek biologicznych, a także na komercyjnym zastosowaniu technologii blockchain. Posiadając wykształcenie z dziedziny elektroniki na Wydziale Elektroniki, Telekomunikacji i Informatyki (ETI), praca magisterska Adama Władzińskiego koncentrowała...
-
Long Distance Geographically Distributed InfiniBand Based Computing
PublikacjaCollaboration between multiple computing centres, referred as federated computing is becom- ing important pillar of High Performance Computing (HPC) and will be one of its key components in the future. To test technical possibilities of future collaboration using 100 Gb optic fiber link (Connection was 900 km in length with 9 ms RTT time) we prepared two scenarios of operation. In the first one, Interdisciplinary Centre for Mathematical...
-
The magnetic field measurements in selected places of the industrial building
Dane BadawczeThe dataset is part of a comprehensive study on the assessment of the electromagnetic field intensity in a building of an operating industrial plant. Detailed results of magnetic field measurements, carried out in selected places of this building, are presented.
-
Computer Support of Analysis of Optical Spectra Measurements
PublikacjaThe verification of measurement errors has a big impact on the assessment of the accuracy of conducted measurements and obtained results. In many cases, computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with a Fabry–Perot interferometer working in the transmission mode. In the measurement setup, a...