Neutral earthing reactor protection
PublikacjaThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
Impulse and high frequency methods of lighting earthing testes.
PublikacjaUziemienia projektowane dla prądów zwarciowych nie zawsze są właściwe do odprowadzania prądów piorunowych, gdzie należy brać pod uwagę impedancję uziemień. W pracy porównano metody: udarową oraz wysokiej częstotliwości zastosowane do oceny przydatności uziemień odgromowych.
-
Earthing effective length for low and high amplitudes of lightning impulse currents
PublikacjaUziemienia w systemie elektroenergetycznym mogą być bardzo rozległe, zwłaszcza ze względu powszechne stosowanie połączeń ekwipotencjalizacyjnych. Ocena tak rozległych systemów z punktu widzenia ich przydatności do celów ochrony odgromowej jest dość trudna, ponieważ tylko część takiego rozległego systemu bierze udział w rozpraszaniu prądu piorunowego w gruncie. Ta część uziomu jest nazywana jego długością efektywną. W pracy zamieszczono...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Influence of span length and impulse front time on earthing measurement accuracy of power line towers
PublikacjaThe article discusses the issue of measuring and assessing the features of power line tower earthings using fast-changing waveform. The study analyses the effect of impulse front time and the line span length on errors made during these measurements using impulse meters. It has been found that the assessment conditions similar to the static measurement results occur for the use of 4 μs current impulses and such procedure is useful...
-
Effective length of lightning earthings
PublikacjaWłaściwości udarowe systemów ochrony odgromowej obiektów wpływają w decydujący sposób na skuteczność takiej ochrony. Z tego względu pomiary skuteczności uziemień powinny być przeprowadzane przy prądach o parametrach czasowych zbliżonych do rzeczywistych prądów piorunowych. Rezystancja udarowa uziemień jest wyznaczana jako iloraz amplitudy spadku napięcia na uziemieniu i amplitudy prądu w układzie pomiarowym. Opisano procedurę pomiaru...
-
Impulse Impedance Measurements of Lightning Protection Earthings
PublikacjaLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
Effective length of lightning protection earthings
PublikacjaSystem uziemień współczesnych obiektów jest zwykle bardzo rozległy, a na łączenie poszczególnych elementów uziemiających za pomocą głównej szyny wyrównania potencjałów uwzględnia także uziemienia stacji transformatorowej. Ocena przydatności takiego systemu uziemień do celów ochrony odgromowej nie jest prosta, bo tylko jego część określana, jako długość efektywna bierze udział w odprowadzaniu do gruntu prądu piorunowego. Praca zawiera...
-
Lightning impulse efficiency of horizontal earthings
PublikacjaSystem uziemień współczesnych obiektów jest zwykle bardzo rozległy, a na łączenie poszczególnych elementów uziemiających za pomocą głównej szyny wyrównania potencjałów uwzględnia także uziemienia stacji transformatorowej. Ocena przydatności takiego systemu uziemień do celów ochrony odgromowej nie jest prosta, bo tylko jego część określana, jako długość efektywna bierze udział w odprowadzaniu do gruntu prądu piorunowego. Praca zawiera...
-
Evaluation of Lightning Protection Earthings by Impulse Tests
PublikacjaW artykule zamieszczono opis nowej procedury pomiaru uziemień odgromowych metodą udarową. Zgodnie z propozycję podczas testu udarowego można pomierzyć nie tylko impedancję udarową uziemienia, ale także ocenić jego rezystancję oraz współczynnik udaru. Wynik takiego badania uwzględnia tylko tę część uziomu, którą określa się jako jego długość efektywną.
-
Impulse measurement accuracy of transmission line earthings
PublikacjaLinie przesyłowe elektroenergetyczne są wyposażone w przewody odgromowe łączące wierzchołki konstrukcji poszczególnych słupów. Zastosowana metoda pomiarów z użyciem udarów prądowych pozwala ocenić rezystancę uziemienia bez odłączania przewodów uziemiających od konstrukcji słupa. W pracy zamieszczono wyniki symulacji komputerowych i pomiarów rzeczywistych uziomów wskazujące, że wpływ równoległego połączenia uziemień całej linii...
-
Impulse Measurements of Tower Earthings of Overhead Transmission Lines
PublikacjaPrzepisy wymagają okresowego badania uziemień słupów elektroenergetycznych linii przesyłowych. pomiary takie metodami klasycznymi niskiej częstotliwości wymagają odłączania uziomów od konstrukcji słupa, co wiąże się z wyłączaniem linii. wykorzstanie metody udarowej do oceny uziemień nie wymaga odłączania uziomów i może byc przeprowadzane podczas pracy linii.
-
Influence of test procedure on surge impedance of lightning earthings.
PublikacjaUziemienia systemu ochrony odgromowej powinny być badane prądami o parametrach czasowych podobnych do rejestrowanych podczas wyładowań atmosferycznych.Podano definicję impedancji i warunki jej pomiaru. omówiono pojęcie długości efektywnej uziomu.
-
Measurement accuracy evaluation of transmission line earthings by impulse tests
PublikacjaUziemienia słupów linii energetycznych powinny być sprawdzane okresowo. Pomiary rezystancji takich uziemień przy pomocy metody niskoczęstotliwościowej wymaga wyłaczania linii i odkręcania przewodów odprowadzających od konstrukcji słupa. Metoda udarowa jest znacznie łatwiejsza w tej aplikacji i nie wymaga wyłaczania linii na czas pomiarów. W pracy oszacowano wpływ uziemień sąsiednich słupów na dokładność pomiarów metodą udarową.
-
A complex evaluation of lightning protection earthings using the impulse testing method
PublikacjaW artykule zamieszczono opis nowej procedury pomiaru uziemień odgromowych metodą udarową. Zgodnie z propozycję podczas testu udarowego można pomierzyć nie tylko impedancję udarową uziemienia, ale także ocenić jego rezystancję oraz współczynnik udaru. Wynik takiego badania uwzględnia tylko tę część uziomu, którą określa się jako jego długość efektywną.
-
Earth wires currents calculation by tableau analysis
PublikacjaThe paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. It allows for the calculation of current distribution in overhead earth wires along the transmission line. Additionally, it may be used to calculate currents in a tower’s earthing system as well as voltages over...
-
Nonlinear secondary arc model use for evaluation of single pole auto-reclosing effectiveness
PublikacjaPurpose – The purpose of this paper is to discuss two evaluation methods of single pole autoreclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc implementation is presented. Design/methodology/approach – A computer simulation studies were...
-
The influence of the motor filtrers on harmonic current emmision in the pro-ective connection of drive systems.
PublikacjaThis paper contains detailed analysis of currents in protective wire in engine supplied from frequency converter without any external filters added. It was found that the peak value of current in protective conductor of engine was about 1500 mA at frequencies 5 Hz 50 Hz. In the continuation of research the dU/dt type motor filter and the sinusoidal filter were tested. It was found that the current in protective wire decreased...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublikacjaThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublikacjaThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Parametry uziemień przy przebiegach udarowych i wysokoczęstotliwościowych
PublikacjaW artykule skupiono się na porównaniu dwóch metod badania impedancji uziemienia odgromowego: udarowej z wysoką częstotliwościową. Zestawiono wyniki pomiarów istniejących uziemień z wynikami komputerowych obliczeń symulacyjnych przeprowadzonych w środowisku programu PSIM. Uzyskane wyniki wskazują na poprawność przyjętego toku modelowania, a uzyskane w ten sposób dane mogą być przydatne w fazie projektowania do szacowania...
-
OCENA WŁAŚCIWOŚCI ROZLEGŁYCH SYSTEMÓW UZIEMIEŃ PRACUJĄCYCH W UKŁADACH OCHRONY ODGROMOWEJ
PublikacjaW wyniku połączenia wszystkich elementów uziemionych w obiekcie budowlanym do szyny ekwipotencjalnej powstaje często bardzo rozległy system uziemień. Ocena tak rozległego systemu za pomocą metod wykorzystujących przebiegi wolnozmienne prowadzi do zbyt optymistycznych wniosków odnośnie do ich właściwości podczas odprowadzania prądów wyładowań atmosferycznych. Pomiary z zastosowaniem metody wykorzystującej przebiegi impulsowe pomiaru...
-
Ocena systemów uziemień z wykorzystaniem pomiarów metodą udarową
PublikacjaW artykule zostały omówione procedury i wymagania stawiane systemom uziemień przez przepisy normalizacyjne z punktu widzenia ich skuteczności w systemie ochrony odgromowej. Podstawą tak sformułowanej oceny są pomiary z zastosowaniem metody udarowej. Metoda taka okazuje się bardzo przydatna zwłaszcza w przypadku uziemień rozległych, jakie pojawiają się we współczesnych obiektach wskutek połączenia różnych elementów uziemiających...
-
ASPEKTY BEZPIECZEŃSTWA W OCENIE WYNIKÓW POMIARÓW UZIEMIEŃ ODGROMOWYCH
PublikacjaOcena rozległego systemu za pomocą metod wykorzystujących przebiegi wolnozmienne prowadzi do zbyt optymistycznych wniosków odnośnie ich właściwości podczas odprowadzania prądów wyładowań atmosferycznych. Bardziej bezpieczne wnioski powstają w wyniku pomiarów z zastosowaniem metody wykorzystującej przebiegi impulsowe, ponieważ wtedy jest uwzględniana tylko ta część nawet bardzo rozległego systemu uziemień, która bierze udział w...
-
OCENA UZIEMIEŃ SŁUPÓW LINII ELEKTROENERGETYCZNYCH ZWŁASZCZA POSADOWIONYCH NA GRUNTACH O WYSOKIEJ REZYSTYWNOŚCI
PublikacjaW artykule została omówiona problematyka pomiaru i oceny właściwości uziemień słupów linii elektroenergetycznych z wykorzystaniem przebiegów wolno-i szybkozmiennych. Uzyskanie odpowiednio niskiej wartości rezystancji uziemienia słupa posadowionego na gruncie o rezystywności powyżej 1000Ωm może być trudne. Praca zawiera analizę zmian właściwości statycznych i udarowych uziemień w funkcji rezystywności...
-
Evaluation Of Single Pole Auto-Reclosing Effectiveness With Nonlinear Secondary Arc Model
PublikacjaThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a non-linear secondary arc implementation is presented. The authors indicate, that precise representation of secondary electric arc leads to more...
-
Electrolytic corrosion of water pipeline system in the remote distance from stray currents– case study
PublikacjaCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800 ÷ 1,000 meters from the point of failure. At the point of failure stray currents flowed from the pipeline...
-
Induced sheath voltages in 110 kV power cables – case study
PublikacjaThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Uziemienia w zespołach elektrowni wiatrowych
PublikacjaW pracy jest omawiana problematyka budowy systemów uziemień na farmach elektrowni wiatrowych. Uziemienia poszczególnych elektrowni są wykorzystywane jako elementy systemu ochrony odgromowej oraz układu ochrony od porażeń otoczenia elektrowni wiatrowej. Farmy elektrowni są często umieszczane na gruntach o wysokiej rezystywności, co utrudnia realizację skutecznych systemów uziemień elektrowni. Trudność może napotykać zwłaszcza wykonanie...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublikacjaElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublikacjaCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
Nowa metoda obliczania rozpływu prądów zwarciowych w przewodach odgromowych linii wysokiego napięcia
PublikacjaReferat przedstawia nowatorską metodę obliczania wartości prądów płynących w przewodach odgromowych w czasie zwarć, pozwalającą na dobór przewodów odgromowych pod względem wytrzymałości cieplnej. Proponowana metoda charakteryzuje się większą dokładnością i większą uniwersalnością niż powszechnie stosowane metody, pozwalając tym samym na dobór przewodów odgromowych z mniejszym ryzykiem niepewności. Prezentowana metoda obliczeniowa...
-
Szybkie uziemniki do ograniczania skutków zwarć łukowych w okrętowych rozdzielnicach SN
PublikacjaW artykule scharakteryzowano moc i napięcie łuku, jak również przedstawiono model termodynamiczny służący do obliczania ciśnienia i temperatury gazów w otoczeniu łuku zwarciowego. Przedstawiono przykładowy układ elektrowni okrętowej i zasilania najważniejszych odbiorników na statku do przewozu gazu ziemnego w stanie ciekłym. Na podstawie parametrów prądnic i silników odbiorników zasilanych z rozdzielnicy głównej obliczono prądy...