Wyniki wyszukiwania dla: ELECTRODE DETECTION
-
Electrode arrays applicable to EIT based mine detection: a comparison ofspatial sensitivity distribution.
PublikacjaPrzebadano trzy konfiguracje matryc elektrodowych. Określono optymalne wzorce pobudzeń oraz odpowiadające im rozkłady czułości.
-
Reduced graphene oxide/iron(II) porphyrazine hybrids on glassy carbon electrode for amperometric detection of NADH and L-cysteine
Publikacja -
Caffeine detection using CB-PLA electrode after Nd:YAG laser ablation in He atmosphere
Dane BadawczeThe dataset contains electrochemical studies in form of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) of laser-activated 3D printed CB-PLA electrodes. The ablation of the 3D-printed CB-PLA electrodes was carried out using a pulsed LaserBlast 500 Nd:YAG laser (Quantel, France) operating at 1064 nm and a 6 ns pulse duration.
-
High resolution XPS analysis of BDD electrode functionalization steps towards SARS-CoV-2 detection
Dane BadawczeThis dataset contains the results of the high-resolution XPS analyses of a set of boron-doped diamond (BDD) electrodes after consecutive functionalization steps toward anchoring of a receptor capable of SARS-CoV-2 virus detection. The analysis was carried out in the binding energy range of C1s, N1s, O1s, Ni2p3/2. The measurements were carried out on...
-
Application of bismuth film electrode for determination of heavy metals by stripping voltammetry
PublikacjaWhen Wang's research group introduced a new type of a working electrode: bismuth film plated electrode (BiFE), it has started attracting increasing attention in the field of electrochemical stripping analysis. These electrodes are shown to be very attractive alternative to common mercury-based electrodes, which are predominantly used in analysis of trace heavy metals.For the determination of heavy metals (Zn, Cd, Pb, Cu) used square...
-
Measurement of sub-nanometer molecular layers with ISFET without a reference electrode dependency
PublikacjaA new method of detection and measurement with sub-nanometer resolution of layers adsorbed or bonded to the ISFET's gate dielectric was presented. The sensitivity of this method is high enough to detect even partial mono-layer covering. The transconductance measurement of the ISFET provides independence of the output signal from pH changes and the driving electrode electrochemical potential instabilities. The stable reference electrode...
-
Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
PublikacjaTwo different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublikacjaCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Electrochemical glucose sensor based on the glucose oxidase entrapped in chitosan immobilized onto laser-processed Au-Ti electrode
PublikacjaThe study on novel electrode material composed of structured titanium foil with embedded Au nanoparticles and modified with chitosan with entrapped glucose oxidase is presented. To confirm the successful immobilization of glucose oxidase FT-IR analysis was performed. The response of electrodes were tested towards glucose in the presence of different interference compounds and biological fluids. The prepared material exhibits excellent...
-
Ultrasensitive electrochemical determination of the cancer biomarker protein sPD-L1 based on a BMS-8-modified gold electrode
PublikacjaThis work describes the modification of a gold electrode with the BMS-8 compound that interacts with the Programmed Death-Ligand 1 (PD-L1), an immune checkpoint protein. The results show that we can confirm the presence of the sPD-L1 in the concentration range of 10−18 to 10−8 M using electrochemical impedance spectroscopy (EIS) with a limit of detection (LOD) of 1.87 × 10−14 M for PD-L1 (S/N = 3.3) and at a concentration of 10−14...
-
Jacek Ryl dr hab. inż.
OsobyStopień doktora nauk technicznych uzyskał w roku 2010. W tym samym roku podjął pracę w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej na Wydziale Chemicznym. W 2018 roku uzyskał stopień doktora habilitowanego nauk technicznych w dyscyplinie technologia chemiczna. Od 2021 roku zatrudniony w Instytucie Nanotechnologii i Inżynierii Materiałowej Wydziału Fizyki Technicznej i Matematyki Stosowanej PG. W pracy naukowej skupia...
-
Electrohydrodynamic Flow Patterns in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode for Various Electrode Geometries
PublikacjaRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engines. In this paper results of 2-dimensional (2D) Particle Image Velocimetry (PIV) measurements of the flow patterns in a narrow ESP for a various electrode geometries are presented. The PIV measurements were carried out in the observation plane that is perpendicular to the ESP duct. The ESP was...
-
Conductive printable electrodes tuned by boron-doped nanodiamond foil additives for nitroexplosive detection
PublikacjaAn efficient additive manufacturing-based composite material fabrication for electrochemical applications is reported. The composite is composed of commercially available graphene-doped polylactide acid (G-PLA) 3D printouts and surface- functionalized with nanocrystalline boron-doped diamond foil (NDF) additives. The NDFs were synthesized on a tantalum substrate and transferred to the 3D-printout surface at 200 °C. No other electrode...
-
Anna Danuta Dettlaff dr inż.
OsobyTytuł magistra inżyniera uzyskała z wyróżnieniem w 2013 roku w Wydziale Chemii Analitycznej. W latach 2013-2017 była doktorantką na kierunku Technologia Chemiczna, podczas których zajmowała się pracą pt. "Badania nad nanokompozytami bazującymi na polimerach przewodzących oraz materiałach węglowych w celu zastosowania ich w superkondensatorach". W 2015 roku odbyła trzymiesięczny staż naukowy w Oldenburgu w Niemczech. Stopień doktora...
-
Estimation of electrode contact in capacitive ECG measurement
PublikacjaIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.
-
Hybrid electrode materials for fast performance devices
PublikacjaEnergy storage devices such as Electrochemical Double Layer Capacitors and other types of the electrochemical capacitors require chemically stable, non-soluble, electrochemically active electrode materials compatible with appropriate electrolytes. Factors which determine their applicability are derived from so called electrochemical window of electroltes, nature of charge accumulation and their kinetics. On the other hand technological...
-
Multisine impedimetric probing of biocatalytic reactions for label-free detection of DEFB1 gene: How to verify that your dog is not human?
PublikacjaAlbert is a dog (Canis familiaris), but he does not realize this. Albert loves human food (and beer), watching movies on the internet, sleeping in bed, and more. But he should not do all these things. To convince him that, we have desinged a test procedure. The DEFB1 gene is unique to human species. Detecting its presence from saliva and in short periods may offer an advantage in the field of forensic medicine, and influence Albert’s...
-
Optical Detection of Ketoprofen by Its Electropolymerization on an Indium Tin Oxide-Coated Optical Fiber Probe
PublikacjaIn this work an application of optical fiber sensors for real-time optical monitoring of electrochemical deposition of ketoprofen during its anodic oxidation is discussed. The sensors were fabricated by reactive magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. ITO tuned in optical properties and thickness allows for achieving a lossy-mode resonance (LMR) phenomenon and it can be...
-
A novel hierarchically-porous diamondized polyacrylonitrile sponge-like electrodes for acetaminophen electrochemical detection
PublikacjaA novel composite electrode material consisting of tangled fibrous polyacrylonitrile-based hierarchically-struc- tured nanocomposites has been produced by wet-spinning, carbonized and decorated with a carbon nano- architecture by microwave plasma-enhanced chemical vapor deposition and investigated as a metal-free electrode for the enhanced electrochemical detection of acetaminophen. Surprisingly, the hierarchical fiber ar- chitecture...
-
3D polypyrrole structures as a sensing material for glucose detection
PublikacjaIn this work, 3D polypyrrole (PPy) structures as material for glucose detection is proposed. Polypyrrole was electrochemically polymerized on platinum screen-printed electrode from an aqueous solution of lithium perchlorate and pyrrole. The growth mechanism of such PPy structures was studied by ex-situ scanning electron microscopy. Preliminary studies show that studied here PPy film is a good candidate as a sensing material for...