Wyniki wyszukiwania dla: IMPEDANCE ANALYSIS
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublikacjaThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublikacjaIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...
-
Determination of pitting corrosion stage of stainless steel by galvanodynamic impedance spectroscopy
PublikacjaThis paper investigates the methodology for differentiation of multistep process of pitting corrosion of AISI 304 stainless steel in the environment of iron (III) chloride. Measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Application of this methodology allowed monitoring of natural corrosion process without external current (IDC = 0A) nor potential perturbation of the system. Applied...
-
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublikacjaThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...
-
Impedance Measurement and Selection of Electrochemical Equivalent Circuit of a Working PEM Fuel Cell Cathode
PublikacjaThe dynamic impedance analysis of direct methanolfuel cell (DMFC) cathode supplied with pure oxygen is pre-sented. Presented results were obtained during dynamic chang-es of the current density in working fuel cell. Investigation ofthe occurring processes at cathode was carried with dynamicelectrochemical impedance spectroscopy (DEIS). A discussionwas conducted based on the determined correlation parameterχ2. It was shown that...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublikacjaThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...
-
Water uptake in protective organic coatings and its reflection in measured coating impedance
PublikacjaWater uptake in commercially available epoxy coating on mild steel using impedance spectroscopy and gravimetry was studied. The water content in the coating was determined using the Brasher-Kingsbury equation and various methods of coating capacitance calculation used in the literature. The obtained results were compared with reference gravimetric data. An overestimation of values obtained from impedance data in relation to gravimetric...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublikacjaThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes
PublikacjaThe most common method of determination of cavitation erosion resistance as well as the magnitude of erosion-corrosion synergistic interaction is based on the weight loss measurements. Nondestructive characterization of installations elements is in most cases impossible to perform. Also, such a measurement does not include local types of failure or alteration of operating conditions. There is an urge to elaborate a method for monitoring...
-
Dynamic impedance measurements of the Direct Methanol Fuel Cell cathode at various operating temperatures
PublikacjaThis article discusses the application of impedance analysis for diagnosing the cathode of a direct methanol fuel cell at various operating temperatures. The Dynamic Electrochemical Impedance Spectroscopy technique coupled with a linear current scan was applied for this purpose. This technique allowed the observation of changes in the cathode's properties in the fuel cell operating under real working conditions. An equivalent model...
-
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublikacjaWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...
-
Galvanostatic impedance measurements for the efficient adsorption isotherm construction in corrosion inhibitor studies
PublikacjaWe present an approach towards an accurate and time-efficient adsorption isotherm determination to evaluate the corrosion inhibitor interaction in electrolytic environments. The approach is based on dynamic impedance spectroscopy measurements in galvanostatic mode (g-DEIS). The studied corrosion inhibitor is continuously injected between the secondary cell and the corrosion cell. The efficiency corresponding to instantaneous inhibitor...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublikacjaThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Communication Model Order Reduction in Hybrid Methods Involving Generalized Impedance Matrix
PublikacjaA novel strategy for the efficient analysis of frequency-domain scattering electromagnetic problems in open and closed domains is presented. A fully automatic model-order reduction technique, called the enhanced reduced-basis method, is applied to increase the efficiency of the hybrid approach, which combines the finite-element and mode-matching methods. Numerical tests show that the proposed algorithm yields reliable and highly...
-
Distribution of relaxation times as a method of separation and identification of complex processes measured by impedance spectroscopy
PublikacjaImpedance spectroscopy is one of the most commonly performed measurements to characterize electronic and electrochemical systems. Impedance spectra have limited resolution and many different processes may overlap what could be the reason of obstructions in its proper later analysis. Up to date, there are three approaches to solve this problem: examining impedance spectra itself, fitting spectra with equivalent circuits, and calculating...
-
Electrochemical properties of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes in solid oxide cells: Impedance study of symmetrical electrodes
PublikacjaThis work evaluates porous Sr0.86Ti0.65Fe0.35O3 (STF35) as a possible oxygen electrode material for Solid Oxide Cells. The powder synthesis was performed by solid state method. Characterization included DC electrical conductivity study of sintered bulk samples and impedance spectroscopy study of symmetrical electrodes deposited on gadolinium doped ceria substrates. Measurements were carried out in atmospheres with different pO2...
-
Evaluation of Temperature Influence on Electrochemical Processes Occurring in a Lithium-Ion Supercapacitor with the Use of Dynamic Electrochemical Impedance Spectroscopy
PublikacjaIn order to obtain the full impedance characteristics of a lithium-ion capacitor as a function of temperature, the authors proposed the use of dynamic electrochemical impedance spectroscopy. Impedance tests were carried out under wide range of dynamic temperature changes for lithium-ion supercapacitors. Significant differences in electrochemical processes were observed as a result of working temperature. Moreover, the quality of...
-
Surrogate modeling of impedance matching transformers by means of variable‐fidelity electromagnetic simulations and nested cokriging
PublikacjaAccurate performance evaluation of microwave components can be carried out using full‐wave electromagnetic (EM) simulation tools, routinely employed for circuit verification but also in the design process itself. Unfortunately, the computational cost of EM‐driven design may be high. This is especially pertinent to tasks entailing considerable number of simulations (eg, parametric optimization, statistical analysis). A possible...
-
Enhanced capacitance of composite TiO2 nanotube / boron-doped diamond electrodes studied by impedance spectroscopy
PublikacjaWe report on the novel composite nanostructures based on boron-doped diamond thin film grown on top of TiO2 nanotubes. The nanostructures made of BDD-modified titania nanotubes showed an increase in activity and performance when used as electrodes in electrochemical environments. The BDD thin films (~200-500 nm) were deposited using microwave plasma assisted chemical vapor deposition (MW PA CVD) onto anodically fabricated TiO2...
-
The non-invasive evaluation of heart function in patients with an acute myocardial infarction: The role of impedance cardiography
PublikacjaBackground: The purpose of this study was to analyze hemodynamic changes in patients treated with percutaneous coronary intervention (PCI) at an early stage of acute myocardial infarction (AMI) and at one-month follow-up. Methods: Patients with AMI (n = 27) who underwent PCI were analyzed using impedance cardiography (ICG). ICG data were collected continuously (beat by beat) during the whole PCI procedure and thereafter at every...