Wyniki wyszukiwania dla: MODEL CALIBRATION
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublikacjaThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...
-
Penetration resistance of Lubiatowo sand in calibration chamber tests
PublikacjaAnaliza oporu na wciskanie na stożku sondy statycznej wciskanej na podstawie badań modelowych w komorze kalibracyjnej z kontrolą naprężeń bocznych. Przeprowadzono badania z zastosowaniem standardowej końcówki CPT, dylatometru DMT, mini-stożka CPT oraz pali modelowych o różnej średnicy. Badania wykonano na piasku modelowym z plaży w Lubiatowie w stanie średnio zagęszczonym i zagęszczonym w szerokim zakresie składowej pionowej naprężenia....
-
Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation
PublikacjaA procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...
-
Calibration-Free Single-Anchor Indoor Localization Using an ESPAR Antenna
PublikacjaIn this paper, we present a novel, low-cost approach to indoor localization that is capable of performing localization processes in real indoor environments and does not require calibration or recalibration procedures. To this end, we propose a single-anchor architecture and design based on an electronically steerable parasitic array radiator (ESPAR) antenna and Nordic Semiconductor nRF52840 utilizing Bluetooth Low Energy (BLE)...
-
Mechanical characterization of a gravel column in a calibration chamber operating as a triaxial cell
PublikacjaA series of tests considering the behavior of gravel columns was performed. A segment of column with a height of 1 m and a diameter of 0.53 m was modelled in a calibration chamber used as a triaxial cell at three different lateral stress applied. The vertical load transferred on the column head was simulated with steady increase of water pressures in the upper and lower membranes. During the loading the volumetric changes in the...
-
A novel calibration method for RSS-based DoA estimation using ESPAR antennas
PublikacjaIn this paper, we introduce a new calibration method that can successfully be used in direction of arrival (DoA) estimation using electronically steerable parasitic array radiator (ESPAR) antennas and employing power-pattern cross-correlation (PPCC) algorithm, which relies on received signal strength (RSS) values recorded at the antenna output port. Instead of the commonly used two-step approach, during which ESPAR antenna calibration...
-
Calibration of POCIS and PASSIL passive samplers – influence of humic acids
Publikacja -
ECU calibration for gaseous dual fuel supply system in compression ignition engines
PublikacjaThe dual fuel (DF) combustion mode is proven solution that allows to improve or get at the same level engine performance and reduce toxic compounds in exhaust gases which is confirmed by researchers and end-users. DF combustion mode uses two fuels gaseous fuel as a primary energy source and a pilot quantity of diesel fuel as ignition source. However, in order, to fully take advantage of the potential of the dual fuel mode, DF system...
-
Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors
PublikacjaMonitoring air pollution is a critical step towards improving public health, particularly when it comes to identifying the primary air pollutants that can have an impact on human health. Among these pollutants, particulate matter (PM) with a diameter of up to 2.5 μ m (or PM2.5) is of particular concern, making it important to continuously and accurately monitor pollution related to PM. The emergence of mobile low-cost PM sensors...
-
Application of auto calibration and linearization algorithms to improve sound quality of computer devices
PublikacjaAn application of auto calibration and linearization algorithms designed for correcting acoustic characteristics of selected computer devices was presented in the paper. The functionality of the algorithms were presented for two kind of computer devices: ultrabook class computer and portable device of All-In-One type. The algorithms were adjusted for the given type of the device on the basis of series of measurements conducted...
-
Spatial Calibration of a Dual PTZ-Fixed Camera System for Tracking Moving Objects in Video
PublikacjaA dual camera setup is proposed, consisting of a fixed (stationary) camera and a pan-tilt-zoom (PTZ) camera, employed in an automatic video surveillance system. The PTZ camera is zoomed in on a selected point in the fixed camera view and it may automatically track a moving object. For this purpose, two camera spatial calibration procedures are proposed. The PTZ camera is calibrated in relation to the fixed camera image, using interpolated...
-
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
PublikacjaIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...
-
Experiments and calibration of a bond-slip relation and efficiency factors for textile reinforcement in concrete
PublikacjaTextile reinforcement yarns consist of many filaments, which can slip relative each other. At modelling of the global structural behaviour, interfilament slip in the yarns, and slip between the yarns and the concrete can be considered by efficiency factors for the stiffness and strength of the yarns, and by applying a bond-slip relation between yarns and concrete. In this work, an effective and robust method for calibration of...
-
Effect of salinity and pH on the calibration of the extraction of pharmaceuticals from water by PASSIL
Publikacja -
Calibration of Passive Samplers for the Monitoring of Pharmaceuticals in Water-Sampling Rate Variation
Publikacja -
<title>Diagnostic and calibration system for the CMS RPC muon trigger</title>
Publikacja -
Verification of ESPAR Antennas Performance in the Simple and Calibration Free Localization System
PublikacjaThis paper presents the results of simulations and measurements of an indoor localization system that uses Electronically Steerable Parasitic Array Radiator (ESPAR) antennas with switched directional beam. Proposed antennas are dedicated for 2.4GHz ISM low-cost applications where determination of the incoming signal is required. The antennas performance is analyzed and verified with relation to positioning methods based on the...
-
Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water
PublikacjaNa Univeristy of Portsmouth (UK) opracowano próbnik pasywny typu Chemcatcher, który może być stosowany do długotrwałego monitoringu organicznych zanieczyszczeń wody. Na działanie wszystkich próbników pasywnych wpływ mają warunki środowiskowe takie jak np. ruch wody czy temperatura. Przed użyciem próbnika Chemcatcher w badaniach polowych wymagana więc była wcześniejsza kalibracja w laboratorium. Przedstawiono wyniki serii doświadczeń...
-
New insights into modeling two-step nitrification in activated sludge systems – The effects of initial biomass concentrations, comammox and heterotrophic activities
PublikacjaIn this study, the conventional two-step nitrification model was extended with complete ammonia oxidation (comammox) and heterotrophic denitrification on soluble microbial products. The data for model calibration/validation were collected at four long-term washout experiments when the solid retention time (SRT) and hydraulic retention time (HRT) were progressively reduced from 4 d to 1 d, with mixed liquor suspended solids (MLSS)...
-
Efficient RSS-Based DoA Estimation for ESPAR Antennas Using Multiplane SDR Calibration Approach
PublikacjaIn this paper, we have introduced a new method to improve overall efficiency of direction-of-arrival (DoA) estimation scheme relying on received signal strength (RSS) values measured at the output port of electronically steerable parasitic array radiator (ESPAR) antenna. The proposed approach uses software-defined radio (SDR) setup and power pattern cross-correlation (PPCC) estimator involving multiple calibration planes. By placing...