Filtry
wszystkich: 35
Wyniki wyszukiwania dla: ODOUR CONCENTRATION
-
Determination of odour concentration by TD-GC×GC–TOF-MS and field olfactometry techniques
PublikacjaField olfactometry is one of the sensory techniques used to determine odour concentration, in atmospheric air, directly in emission sources. A two-dimensional gas chromatography with time of flight mass spectrometer (GC×GC–TOF-MS) allows performing the chemical characterization of various groups of chemical compounds, even in complex mixtures. Application of these techniques enabled determination of odour concentration level in...
-
Application of Electronic Nose to Ambient Air Quality Evaluation With Respect to Odour Nuisance in Vicinity of Municipal Landfills and Sewage Treatment
PublikacjaThis chapter contains information about application of the electronic nose type instruments to evaluation of ambient air odour quality connected with such sectors of human activity as municipal landfills or sewage treatment plants. The authors present potential sources of emission from these sectors, characterize the chemical compounds responsible for presence of unpleasant odours, describe the influence of those compounds on human...
-
Monitoring of odour nuisance in the Tricity Agglomeration
PublikacjaThe paper describes a principle of operation of odour nuisance monitoring network, which is being designed in the Tricity Agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The...
-
Evaluation of Health Hazard Due to Emission of Volatile Organic Compounds from Various Processing Units of Wastewater Treatment Plant
PublikacjaThe paper describes an attempt at health risk assessment and odour concentration determination in the most important units of a wastewater treatment plant. The cancer risk (CR) and hazard index (HI) parameters in selected measurement locations were calculated based on the results of chromatographic analyses (GCxGC-TOF-MS) and the United States Environmental Protection Agency (US EPA) guidelines. No exceedance of the CR and HI acceptable...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublikacjaThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublikacjaThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Biotrickling filtration of n-butanol vapors: process monitoring using electronic nose and artificial neural network
PublikacjaBiotrickling filtration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype combined with artificial neural network for biofiltration process monitoring in terms of reduction in n-butanol concentration and odour intensity of treated air. The study...
-
IDENTIFICATION OF ODOR OF VOLATILE ORGANIC COMPOUNDS USING CLASSICAL SENSORY ANALYSIS AND ELECTRONIC NOSE TECHNIQUE
PublikacjaThe paper compares two methods of analysis of odour of volatile organic compounds: classical sensory analysis and electronic nose technique. Eight volunteers participated in the classical sensory analysis investigations, which lasted two weeks. An instrumental odour analysis involved a prototype of 6-sensor electronic nose designed by the authors. The research performed with this device provided higher reproducibility and reliability...
-
Complementary use of GCxGC–TOF–MS and statistics for differentiation of variety in biosolid samples
PublikacjaFormation of biosolid cakes, which are one of the main wastes generated in wastewater treatment plants, is connected with emission of many hazardous chemical compounds, including odoriferous ones. To optimize particular processes of biosolid cake processing, it is necessary to assess chemical composition of the gas mixtures containing the compounds released from the cakes. The paper proposes application of two-dimensional gas chromatography...
-
Investigation of Air Quality beside a Municipal Landfill: The Fate of Malodour Compounds as a Model VOC
PublikacjaThis paper presents the results of an investigation on ambient air odour quality in the vicinity of a municipal landfill. The investigations were carried out during the spring–winter and the spring seasons using two types of the electronic nose instrument. The field olfactometers were employed to determine the mean odour concentration, which was from 2.1 to 32.2 ou/m3 depending on the measurement site and season of the year. In...
-
Direct measurements of odorous volatile organic compounds present in biosolids cakes by Proton Transfer Reaction – Mass Spectrometry Technique
PublikacjaThis paper show the results of investigation of concentration of odorous chemical compounds emitted upon ageing of anaerobically stabilised biosolids that could contribute to the overall odour character of nuisance emissions. Biosolids samples from wastewater treatment plant were collected in spring time. Concentrations of volatile organic compounds using a US EPA flux hood and Proton Transfer Reaction-Time of Flight-Mass Spectrometry...
-
Odour Perception Using a Sniffing Team at a Municipal Solid Waste Treatment Plant: A Case Study
PublikacjaThe monitoring of odour intensity, generated by a landfill area, is a difficult activity since it is a multi-source problem with discontinuous odour emissions. A modified sniffing team method is described here and applied to determine the main odour sources in a landfill located in Pomerania, Poland. Four consecutive test sessions were performed during the following months: August, December, April, and June. It was found that the...
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublikacjaMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...
-
Evaluation of Ambient Air Odour Quality in Vicinity of Municipal Landfill Using Electronic Nose Technique
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of municipal landfill. The investigation was carried out with a prototype of electronic nose and a team of panelists utilizing the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. Performed measurements...
-
A case study of odour nuisance evaluation in the context of integrated urban planning
PublikacjaOdour nuisance poses a serious problem in many urban areas, yet its evaluation and mitigation is often omitted in the urban planning process. By identifying its range and spatio-temporal variations, it could be taken into consideration by planners in urban development strategies and land use decisions. The aim of the study was to present the application of odour evaluation techniques in the improvement of the quality of life in...
-
Determination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose
PublikacjaThe paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures—toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene — characterized by different odour intensity and hedonic tone. A principal component regression (PCR) calibration...
-
Differences between selected volatile aromatic compound concentrations in sludge samples in various steps of wastewater treatment plant operations
PublikacjaSewage sludge, one of the main wastes generated during wastewater treatment, constitutes an important source of emissions of volatile chemical compounds such as volatile aromatic compounds These substances may undergo various changes as a result of operations and unit processes, which affects their concentrations in sewage sludge. An important factor determining the potential hazardousness of volatile organic compounds is the quality...
-
Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks
PublikacjaThis paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills and sewage treatment plants were subjected...
-
Comparison of the Measurement Techniques Employed for Evaluation of Ambient Air Odour Quality Influenced by Operation of Industrial Sewage Treatment Plant
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of a sewage treatment plant of the LOTOS Group S.A. petroleum plant. The investigation was performed during winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type...
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublikacjaThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...