Filtry
wszystkich: 4346
-
Katalog
- Publikacje 3160 wyników po odfiltrowaniu
- Czasopisma 141 wyników po odfiltrowaniu
- Konferencje 19 wyników po odfiltrowaniu
- Osoby 190 wyników po odfiltrowaniu
- Projekty 3 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 77 wyników po odfiltrowaniu
- Dane Badawcze 755 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: automatic voltage control
-
Experimental test results of an automatic voltage regulator with independent phase voltage controllers
PublikacjaThe growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...
-
AUTOMATIC CONTROL AND COMPUTER SCIENCES
Czasopisma -
IEEE TRANSACTIONS ON AUTOMATIC CONTROL
Czasopisma -
International Review of Automatic Control (IREACO)
Czasopisma -
Control strategies and comparison of the Dynamic Voltage Restorer
PublikacjaThis paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...
-
Predictive Current Control of Voltage-Source Inverter.
PublikacjaW artykule przedstawiono regulator prądu stojana silnika asynchronicznego z predykcją napiecia wyjściowego. Rozważono aspekty praktycznej realizacji algorytmu w układzie z procesorem sygnałowym związane z opóźnieniami pomiaru prądu przy zastosowaniu przetwornika A/C. Układ zrealizowano praktycznie przy wykorzystaniu układu FPGA. W pracy zamieszczono wyniki badań symulacyjnychi eksperymentalnych.
-
Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control
PublikacjaA new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...
-
Voltage control in a power system with renewable sources of energy
PublikacjaIntensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...
-
An Automatic Self-Tuning Control System Design for an Inverted Pendulum
PublikacjaA control problem of an inverted pendulum in the presence of parametric uncertainty has been investigated in this paper. In particular, synthesis and implementation of an automatic self-tuning regulator for a real inverted pendulum have been given. The main cores of the control system are a swing-up control method and a stabilisation regulator. The first one is based on the energy of an inverted pendulum, whereas the second one...
-
Design of synchronous generator voltage regulator based on h control theory
PublikacjaThe power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...
-
Control of voltage source inverter without dead-time effects.
PublikacjaW artykule zaproponowano metodę dokładnego generowania wektora napięcia o małej amplitudzie w falowniku napięcia. Zaprezentowano metodę modulacji szerokości impulsów, w której wyeliminowano koniecznosć wprowadzania czasów martwych oraz kompensacji ich wpływu na napięcie wyjsciowe przekształtnika
-
Automatic control systems for ships fitted with podded propulsion drive (POD).
PublikacjaW artykule ukazano celowość i możliwości automatyzacji układów napędowych, zwłaszcza typu POD, przewidzianych do zastosowania na projektowanych w ramach projektu Eureka BALTECOLOGICAL SHIP czterech statkach bałtyckich: kontenerowca, pojazdowa i tankowca oraz statku rzeczno - morskiego. Zawarte w artykule informacje ułatwiają dokonanie wyboru właściwych założeń projektowanego układu sterowania napędem wymienionych wyżej statków.
-
Voltage Control of a Stand-Alone Multiphase Doubly Fed Induction Generator
PublikacjaThis article presents a multiphase doubly fed induction generator (MDFIG) with a dedicated and unique control algorithm in a stand-alone wind energy conversion system. The algorithm has been developed and elaborated in the case of different emergency modes. Compared with the traditional double-fed induction generator, the MDFIG has increased reliability, reduced current level per phase, and low rotor harmonic currents. The control...
-
Control of a wind power generator in case of voltage sags in power network
PublikacjaW artykule poruszono problem związany ze sposobem sterowania generatorem elektrowni wiatrowej w przypadku wystąpienia po stronie sieci zapadów napięcia.Jako generator wykorzystano maszynę dwustronnie zasilaną której stojan podłączono bezpośrednio do sieci natomiast wirnik zasilano poprzez kaskadę przekształtników. Wystąpienie spadku lub zapadu napięcia sieci w przypadku pracy tego typu generatora może doprowadzić do uszkodzenia...
-
Design of synchronous generator voltage regulator based on H control theory
PublikacjaSystemy dużej mocy są z reguły systemami o dużej nieliniowości. Wynika to z dynamiki takiego obiektu jak również jego konfiguracji itd. Istnieje wiele metod umożliwiających sterowanie czy testowanie zaprojektowanych generatorów. W artykule analizowana jest metoda projektowania regulatora napięcia w oparciu o H. Wyniki symulacji są zadowalające, ponieważ tak zaprojektowany regulator lepiej tłumi kołysania elektromechaniczne niż...
-
Dynamic variables limitation for backstepping control of induction machine and voltage source converter
PublikacjaDynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublikacjaThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Studies of the Modelling Accuracy of Steam Turbine Control Systems for Diagnostic Tests of Automatic Synchronizers
PublikacjaOne of the important factors that affect the reliable operation of the power system and the rapid restitution after disaster is a quick and effective combining synchronous electric power facilities to operate in parallel. Hence, diagnostics of automatic synchronizers at every stage of their life, from building a prototype, through the whole life, until removing such devices from the operation, is an extremely important and responsible...
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublikacjaCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
Hydro Power Plant in the Process of Voltage Control in the Electric Power System and the System Restoration
PublikacjaThe article covers selected issues related to the share of hydroelectric power in the process of rebuilding the power system after black-out and voltage control during that process. Selected results of measurements made during the creation of the transmission chain for the need to start a block of a thermal power plant from a hydroelectric power plant were presented.
-
Hybridized SVPWM Algorithm for Multilevel CHB Inverter With DC-Link Voltage Control Capability
PublikacjaThe deployment of a space vector pulsewidth modulation (SVPWM) scheme in controlling cascaded H-bridge multilevel inverter (CHB MLI) is quite challenging; especially, when a substantial number of output voltage levels are involved and the dc-link voltages are out of balance. In this article, a simple SVPWM algorithm for CHB MLI is proposed. In the proposed algorithm, all the H-bridges in an inverter phase are treated as a single...
-
Sensorless control system of induction machine supplied by voltage source inverter with output filter
PublikacjaThe paper focuses on sensorless control of the induction machines supplied by inverter with the output filters. “The novel” idea of the speed observer which is based on the backstepping approach is shown. The standard structure of the exponential observer is extended by the integrators and additional Z vector. The simulation and experimental results validate the proposed solution.
-
Automatic resource identification for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard
Publikacja -
Four Level Diode-Clamped Back-To-Back Converter with Active DC Link Voltage Control
PublikacjaThis article presents the design and control of 4L-DC back-to-back converter. To solve the DC link voltage balancing problem in four-level converter a new three-level double chopper topology based on PO-PWM modulation was designed and successfully tested. Also, the paper describes two phase space vector pulse width modulation 2P-SVPWM based on the shape function of finite elements. The control structure with modified Dead-Beat...
-
Mathematical Models of Control Systems of Angular Speed of Steam Turbines for Diagnostic Tests of Automatic and Mechatronic Devices
PublikacjaAccurate modeling of physical processes of many automatics and mechatronics systems is often necessity. In power system such a process is control of angular velocity of power objects during connection to operation in parallel. This process is extremely dynamic. For this reason response of control system depends from changes of many physical parameters (temperature, pressure and flow of the medium, etc.). Precision modeling influences...
-
Automatic configuration of FMC boards for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard
Publikacja -
Automatic HDL firmware generation for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard
Publikacja -
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublikacjaThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
space-vector pulse width modulation for three-level npc converter with the neutral point voltage control
PublikacjaPrzedstawiono strategię modulacji PWM dla trójpoziomowych falowników NPC z predykcją i kompensacją asymetrii rozkładu napięcia na kondensatorach obwodu pośredniczącego
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublikacjaThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
Publikacja -
Specificity of automatic control of micro-turbines (steam or gas -driven and expanders) in dispersed generation system of heat and electric power
PublikacjaThis paper presents specific problems of automatic control of steam micro-turbines and expanders intended for the dispersed, combined generating of heat and electric power. The investigations concern ensurance of certainty of energy supply and its required quality.
-
Investigation of the Process of Automatic Control of Current Polarity Reversal in the Conditions of Hybrid Technology of Electrochemical Processing of Corrosion-Resistant Steels
Publikacja -
Increasing the Utilization of dc-link Voltage of a Five-Leg VSI Based on Rotor Angle Control of Dual Induction Motors
PublikacjaThis paper introduces an increased utilization of the dc-link voltage of a five-leg voltage source inverter (VSI) based on the rotor flux angle control technique for dual induction motors, IM. The main purpose is to utilize additional abilities provided by a multi-motor drive system in limited operating conditions. Generally, a multi-motor drive system is widely used in electric vehicles (EVs), traction systems and in several industrial...
-
The extended model predictive-sliding mode control of three-level AC/DC power converters with output voltage and load resistance variations
Publikacja -
Romanian Journal of Information Technology and Automatic Control-Revista Romana de Informatica si Automatica
Czasopisma -
International Federation of Automatic Control World Congress
Konferencje -
2022/2023_zima SCADA Systems in Automatic Control
Kursy OnlineSCADA Systems in Automatic Control - project materials
-
2021/2022_zima SCADA Systems in Automatic Control
Kursy OnlineSCADA Systems in Automatic Control - project materials
-
2022/2023_ZIMA Automatic Control & Robotics
Kursy OnlineLecture and laboratory
-
2023/2024_ZIMA Automatic Control & Robotics
Kursy OnlineLecture and laboratory
-
2024/2025_ZIMA Automatic Control & Robotics
Kursy OnlineLecture and laboratory
-
2024/2025_ZIMA Automatic Control & Robotics
Kursy OnlineLecture and laboratory
-
2024/2025_WINTER SCADA systems in automatic control (project)
Kursy OnlineSCADA Systems in Automatic Control - project materials
-
Self-Optimizing Adaptive Vibration Controller
PublikacjaThis paper presents a new approach to rejection of sinusoidal disturbances acting at the output of a discrete-time linear stable plant with unknown dynamics. It is assumed that the frequency of the sinusoidal disturbance is known, and that the output signal is contaminated with wideband measurement noise. The proposed controller, called SONIC (self-optimizing narrowband interference canceller), combines the coefficient fixing technique,...
-
New Approach to Noncasual Identification of Nonstationary Stochastic FIR Systems Subject to Both Smooth and Abrupt Parameter Changes
PublikacjaIn this technical note, we consider the problem of finite-interval parameter smoothing for a class of nonstationary linear stochastic systems subject to both smooth and abrupt parameter changes. The proposed parallel estimation scheme combines the estimates yielded by several exponentially weighted basis function algorithms. The resulting smoother automatically adjusts its smoothing bandwidth to the type and rate of nonstationarity...
-
Lattice filter based multivariate autoregressive spectral estimation with joint model order and estimation bandwidth adaptation
PublikacjaThe problem of parametric, autoregressive model based estimation of a time-varying spectral density function of a multivariate nonstationary process is considered. It is shown that estimation results can be considerably improved if identification of the autoregressive model is carried out using the two-sided doubly exponentially weighted lattice algorithm which combines results yielded by two one-sided lattice algorithms running...
-
Design of synchronous generator two inputs regulator based on hinf control theory.
PublikacjaThe power system is highly nonlinear system, its dynamics depends on system network configuration, system loading… etc. To overcome the above mentioned difficulties and fulfill the performance requirements the different control methods are considered and tested for design of synchronous generator control system. Application of the H optimization method to synchronous generator regulator based on measurement of generator voltage...
-
Zdzisław Kowalczuk prof. dr hab. inż.
OsobyW 1978 ukończył studia w zakresie automatyki i informatyki na Wydziale Elektroniki Politechniki Gdańskiej, następnie rozpoczął pracę na macierzystej uczelni. W 1986 obronił pracę doktorską, w 1993 habilitował się na Politechnice Śląskiej na podstawie pracy Dyskretne modele w projektowaniu układów sterowania. W 1996 mianowany profesorem nadzwyczajnym, w 2003 otrzymał tytuł profesora nauk technicznych. W 2006 założył i od tego czasu...
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublikacjaThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...