Filtry
wszystkich: 2755
wybranych: 175
-
Katalog
- Publikacje 2245 wyników po odfiltrowaniu
- Czasopisma 117 wyników po odfiltrowaniu
- Konferencje 53 wyników po odfiltrowaniu
- Osoby 69 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Kursy Online 46 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 223 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: ADHESIVE PRESSING
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Twenty years' (1996-2016) tropospheric parameters for selected EPN stations derived from GPS double-difference processing
Dane BadawczePropagation of global navigation satellite systems (GNSS) signals through the Earth’s atmosphere is affected by its physical properties. Both hydrostatic and wet part of the atmosphere (mostly related with troposphere) causes delays of GNSS signal, which usually are expressed in the zenith direction (zenith hydrostatic delay - ZHD, and zenith wet delay...
-
SYNAT_MUSIC_GENRE_FV_173
Dane BadawczeThis is the original dataset containing 51582 music tracks (22 music genres) and 173 element-feature vector [1-6,9]. A collection of more than 50000 music excerpts described with a set of descriptors obtained through the analysis of 30-second mp3 recordings was gathered in a database called SYNAT. The SYNAT database was realized by the Gdansk University...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Gdansk 2020, 3 Maja street - video data - pedestrian, bicycles, vehicles
Dane BadawczeThe data contain video traffic data (pedestrian, cyclists, vehicles) registered at 3 Maja street (3 Maja - Al. Zwyciestwa - Blednik - Trakt Konny crossing). Date 06.08.2020 6:00-22:00. The video camera was installed around bicycle crossings and pedestrian crossings at crossing. Camera was mounted on 7-meter-high mast.
-
Gdansk 2020, Bora Komorowskiego street - video data - pedestrian, bicycles, vehicles
Dane BadawczeThe data contain video traffic data (pedestrian, cyclists, vehicles) registered at Bora Komorowskiego street (Bora Komorowskiego - Chlopska - Obroncow Wybrzeza crossing). Date 06.08.2020 6:00-22:00. The video camera was installed around bicycle crossings and pedestrian crossings at crossing. Camera was mounted on 7-meter-high mast.
-
Study of the influence of the presence of Dr fimbriae on the hydrophobicity of cells of recombinant Escherichia coli strains: AAEC191A and BL21(DE3)
Dane BadawczeThe ability of a cell surface to repel or adhere to surfaces is crucial, and it was assessed through a microbiological adhesion test involving hexadecane and xylene. In this method, microorganisms in an aqueous layer are mixed with an organic layer, and after completion, the absorbance of each sample is measured at a 570 nm wavelength. The results obtained...
-
SYNAT Music Genre Parameters PCA 19
Dane BadawczeThe dataset contains feature vector after Principal Component Analysis (PCA) performing, so there are 11 music genres and 19-element vector derived from music excerpts. Originally, a feature vector containing 173 elements was conceived in earlier research studies carried out by the team of authors [1-6]. A collection of 52532 music excerpts described...
-
SYNAT_PCA_48
Dane BadawczeThere is a series of datasets containing feature vectors derived from music tracks. The dataset contains 51582 music tracks (22 music genres) and feature vector after Principal Component Analysis (PCA) performing, so there are 48-element vectors derived from music excerpts. Originally, a feature vector containing 173 elements was conceived in earlier...
-
SYNAT_PCA_11
Dane BadawczeThe dataset contains 51582 music tracks (22 music genres) and feature vector after Principal Component Analysis (PCA) performing, so there are 11-element vectors derived from music excerpts. Originally, a feature vector containing 173 elements was conceived in earlier research studies carried out by the team of authors [1-6]. A collection of more than...
-
Historical Wreck Inventory
Dane BadawczeThe measurement solution results in a point cloud obtained from the Leica P30 laser scanner. Another element is the processing of photos into point clouds with the Zenmuse P1 camera of the unmanned Matrice 300 RTK aircraft. The measurement provides complete geometrical information about the wreck. The measurement took place as part of the Photogrammetry...
-
Automatically created and partially veriffied Wikipedia - WordNet mappings
Dane BadawczeMapping between Wikipedia articles and WordNet synsets. The mappings between Wikipedia articles and WordNet synsets were obtained automatically using 4 algorithms of data processing. The automatically generated mappings were than a subject of verification by a group of volunteers using crowdsourcing approach through so called Games with a Purpose. The...
-
Gdansk 2020, Krynicka (S) street - video data - pedestrian, bicycles, vehicles
Dane BadawczeThe data contain video traffic data (pedestrian, cyclists, vehicles) registered at Krynicka (S) street. Date 11.08.2020, 6:00-20:00. The video camera was installed around bicycle crossings and pedestrian crossings at Krynicka - Kolobrzeska crossing. Camera was mounted on 7-meter-high mast.
-
Video recordings of static hand gestures for gesture based interaction
Dane BadawczeThis data set contains video recording of selected simple hand gestures related to sign language. The purpose of the data set is to evaluate different computer algorithms design for hand gesture detection as well as for hand features and hand pose detection and identification. The data set contains 5 video recordings in mp4 format. Each recording is...
-
Force-deformation spectroscopy in contact mode
Dane BadawczeThe deformation-distance spectroscopic curve is obtained by registering the value of the probe cantilever deflection as a function of the elongation of the piezoelectric scanner. It assumes a simple relationship in the form of Hooke’s law, linking the deformation of the lever with the amount of its deflection caused by the proximity of the probe and...
-
Fingerprint structure studies with semi-contact AFM
Dane BadawczeThe work [1] presents many, sometimes even surprising examples of the use of atomic force microscopy in modern forensics. Some of them are projectile tests using the characteristic scratch patterns created by the firing pin on the primer. There are more and more suggestions in the literature for the use of atomic force microscopy in dactyloscopy [2]....
-
Gdansk 2020, Jagielonska street - video data - pedestrian, bicycles, vehicles
Dane BadawczeGdansk 2020, Miszewskiego street - video data - pedestrian, bicycles, vehicles
-
3D point cloud as a representation of silo / tank
Dane BadawczeThe product presents a point cloud in the set of coordinates X Y Z. The data was obtained by terrestrial laser scanning and its processing for the analysis of tanks geometry. The development process indicates the possibility to obtain the reliable results useful for the evaluation of the tank side surfaces geometry.
-
Input files for the Floodsar software
Dane BadawczeInput files for the Floodsar softwareAuthor: Tomasz Berezowski, Gdansk University of Technology, tomberez@eti.pg.edu.pl
-
Correction of far-field measurements obtained in non-anechoic test site
Dane BadawczeThe dataset contains raw and processed measurements of radiation pattern characteristics performed in non-anechoic regime for two geometrically small antenna structures: a spline-parameterized Vivaldi structure and a compact spline-based monopole. The responses have been obtained at the selected frequencies of interest as a function of mentioned structures...
-
Transmission measurements between two geometrically small Vivaldi antennas performed in non-anechoic propagation conditions
Dane BadawczeThe dataset contains unprocessed measurements of complex transmission (and reflection) characteristics obtained in non-anechoic regime for a geometrically small, broadband spline-parameterized Vivaldi structure. The measurement setup comprises two Vivaldi antennas with the same topology where one is used as a reference structure, and another one as...
-
Structural investigations of the LTO:Cu thin films
Dane BadawczeLithium titanate (Li1+xTi2-xO4) doped with Cu2+ ions was synthesized by sol-gel processing method. The structure was characterized by X-ray Diffraction (XRD). All samples revealed presence of LTO spinel phase. X-ray pattern of undoped LTO was free of any impurities and other crystal phases. Similarly, samples with low amount of copper dopant (x = 0.05...
-
Development of conductive porous media as packing materials for biotrickling filter – microbial fuel cell system (BTF-MFC system)
Dane BadawczeDataset presents values of electrical resistance measured for three developed conductive packimg materials for the application in a BTF-MFC system.
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Radiation pattern measurements of geometrically small antennas performed in non-anechoic environments
Dane BadawczeThe dataset contains unprocessed measurements of radiation pattern characteristics performed in non-anechoic regime for three geometrically small antenna structures: a spline-parameterized Vivaldi structure, a compact spline-based monopole, and a quasi-Yagi geometry with enhanced bandwidth. The responses have been obtained over broad frequency ranges...
-
Measurements of electrically small antenna radiation patterns in non-anechoic environments using TGM
Dane BadawczeThe dataset contains raw and processed measurements of radiation pattern characteristics performed in non-anechoic regime for four antenna structures: a spline-parameterized Vivaldi structure, a compact spline-based monopole, super-ultrawideband antenna, and a quasi-Yagi component. The responses have been obtained at the selected frequencies of interest...
-
SEM/EDX data of (Cr,Fe,Mn,Co,Ni)3O4 High-entropy spinel oxide thin films deposited on amorphous SiO2 substrate by spray pyrolysis techniqe
Dane BadawczeThis Data set include SEM and EDX results of (Mn,Co,Fe,Ni,Cr)3O4 high-entropy spinel oxide prepared in the form of a ~ 500 nm thin film utilising a facile spray pyrolysis technique. The structural and electrical properties of the layers were characterised after exposure to temperatures in the range of 400–900 ◦C. The as-deposited layers were amorphous,...
-
TEM data of (Cr,Fe,Mn,Co,Ni)3O4 High-entropy spinel oxide thin films deposited on amorphous SiO2 substrate by spray pyrolysis techniqe
Dane BadawczeThis Dataset include presentation of summarized TEM investigation of (Mn,Co,Fe,Ni,Cr)3O4 high-entropy spinel oxide prepared in the form of a ~ 500 nm thin film utilising a facile spray pyrolysis technique. The structural and electrical properties of the layers were characterised after exposure to temperatures in the range of 400–900 ◦C. The as-deposited...
-
Effects of liquid phase modification on the values of surface tension of trickling liquid
Dane BadawczeDataset presents the values of surface tension of trickling liquid sampled from three running biotrickling filters.