Filtry
wszystkich: 3119
wybranych: 219
-
Katalog
- Publikacje 2648 wyników po odfiltrowaniu
- Czasopisma 82 wyników po odfiltrowaniu
- Konferencje 24 wyników po odfiltrowaniu
- Osoby 85 wyników po odfiltrowaniu
- Projekty 6 wyników po odfiltrowaniu
- Kursy Online 48 wyników po odfiltrowaniu
- Wydarzenia 7 wyników po odfiltrowaniu
- Dane Badawcze 219 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: HONEY QUALITY
-
Terrestrial Survey Images - 3D Exterior Model - Gdansk Church Pw. Św. Wojciecha - NICON D5300
Dane BadawczeDataset description: Raw images from photogrammetric survey. Object: Kościół Rzymskokatolicki Pw. Św. WojciechaLocation: Gdansk, Pomerania, PolandDrone type: N/A (terrestrial images)Flight plan: Free - walk around the object with camera. 3 images taken at the point.Target Product: 3D ModelDate: 02.04.2022Direct georeferencing: yesMetadata data: yes/GPSGCP:...
-
Terrestrial Survey Images - 3D Interior Model - Gdansk Church Pw. Św. Wojciecha - NICON D5300
Dane BadawczeDataset description: Raw images from photogrammetric survey. Object: Kościół Rzymskokatolicki Pw. Św. WojciechaLocation: Gdansk, Pomerania, PolandDrone type: N/A (terrestrial images)Flight plan: Free plan (walk inside the object)Target Product: 3D Interior ModelDate: 02.04.2022Direct georeferencing: yesMetadata data: no/GPSGCP: NOGCP Quality: N/ACamera...
-
Split-beam echosounder data from Puck Bay autumn 2018 Part II
Dane BadawczeThe acoustic data was collected in 2018, in the Bay of Puck, in the seasons: autumn. Data was collected during the day and night. Three split-beam echosounders with frequencies of 38 kHz, 120 kHz and 333 kHz were used to collect the data. The data was collected at a designated study area not far from the city of Hel and on the route Hel - Gdynia while...
-
Data from the survey on assessment of satisfaction with graduating from Gdańsk University of Technology in the opinion of foreign graduates
Dane BadawczeThe dataset includes data from the survey on the Gdańsk University of Technology foreign graduates’ on assessment of satisfaction with graduating from university. The research was conducted over a four-month period, from December 2019 to March 2020, using the Computer-Assisted Web Interview (CAWI). The research sample included 142 respondents. The study...
-
Rain Gardens SW particle size analysis dataset
Dane BadawczeThis dataset contains the results of laser diffraction particle size analysis of storm water runoff and storm water quality in rain garden units. Samples were collected from 4 different rain gardens in Gdansk, Poland.
-
Horizon Europe proposals - Administrative Part
Dane BadawczeThe dataset contains data collected during the HE National Contact Point training on Oct. 12, 2022, reg. the administrative part of Horizon Europe grant proposals. The data set includes presentations concerning administrative forms of 2022 proposals and their content, including participant data; information about abstract writing, keyword choice and...
-
Study on the student's perception of marketing activities undertaken by Gdansk and Mangalore
Dane BadawczeNowadays, the urban areas very often attract the poor and the unemployed, leading to the creation of neighbourhoods of poverty (slums) and other economic and social problems. All over the World cities include sustainable goals in their development strategies but the question is, whether the city development strategies foresee activities devoted also...
-
Results of calibration of the piezoelectric scanner using the probe TGQ1
Dane BadawczeTeaching file. Results of calibration of the piezoelectric scanner using the probe TGQ1. Scanning in contact mode. NTEGRA Prima (NT-MDT) device. CSG probe 10.
-
The surface of a fragment of the structure of an integrated circuit in the semi-contact mode.
Dane BadawczeThe surface of a fragment of the structure of an integrated circuit. Topographic measurements in the semi-contact mode. NTEGRA Prima (NT-MDT) device. NSG 01 probe.
-
TG analyses - content of SiO2 and TiO2 in polystyrene
Dane BadawczeTG analyses were performed for polystyrene spheres coating by SiO2 and then coating by SiO2-TiO2. Thermal analyses of polystyrene spheres only were also performed. The content of inorganic remaining was used for calculation the quantity of coating SiO2 and TiO2 in the polystyrene spheres.
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.4
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.5
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.3
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Terrestrial Survey Images - Multispectral Exterior Model - Gdansk Church Pw. Św. Wojciecha - Micasense Dual
Dane BadawczeDataset description: Raw images from photogrammetric survey. Object: Kościół Rzymskokatolicki Pw. Św. WojciechaLocation: Gdansk, Pomerania, PolandDrone type: N/A (terrestrial images)Flight plan: Free - walk around the object with camera. 3 images taken at the point.Target Product: 3D Model - Multispectral ModelDate: 24.04.2022Direct georeferencing:...
-
Atomic force microscopy images of copper electrical contacts wear under the influence of friction
Dane BadawczeMeasurement of wear of copper electrical contacts under the influence of friction. Imaging in contact mode in the variant of scanning spreading resistance microscopy. Additionally, there are spectroscopic current-voltage curves showing local changes in electrical conductivity. NTEGRA Prima (NT-MDT) device. Probe NSG 01Pt.
-
Long term measurements of PM1, PM2.5, PM10 and NO2 in open-air at Gdansk (Poland) area using low-cost sensors together with the reference results
Dane BadawczeThe measurements results of open-air measurements made using the following low-cost sensors: particulate matter (PM) sensor SPS30 from Sensirion, NO2 electrochemical sensor SGX-7NO2 from SGX Sensortech, NO2 electrochemical sensor 7E4-NO2 from SemaTech, compact MOS air quality sensor MiCS 2714 from SGX Sensortech, BME280 (Bosch) environmental sensor...
-
ECG measurement in the bathtub - getting into the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
SegSperm - a dataset of sperm images for blurry and small object segmentation
Dane BadawczeMany deep learning applications require figure-ground segmentation. The performance of segmentation models varies across modalities and acquisition settings.
-
Detection of the acoustic interferences during AFM operation
Dane BadawczeAtomic force microscopy is a particularly complicated surface imaging technique due to the large number of factors that affect the quality of the resulting images. They are obviously difficult and sometimes even impossible to control at the same time. One of such factors may even be the seismological location of the building or the influence of mechanical...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - buttocks electrodes, reinforcement 2x smaller, drl on knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Surface EMG-based signal acquisition for decoding hand movements
Dane BadawczeBiosignal processing plays a crucial role in modern hand prosthetics. The challenge is to restore functionality of a lost limb based on the signals acquired from the surface of the stump. The number of sensors (emg channels) used for signal acquisition influence the quality of a prosthetic hand. Modern algorithms (including neural networks) can significantly...
-
The luminescence study of Ga1.98–xAlxO3:0.02Cr3+ coumpounds.
Dane BadawczeA chemical and mechanical pressure-induced photoluminescence tuning method was developed through structural evolution and hydrostatic pressure involving phase transition. A series of Ga1.98−xAlxO3:0.02Cr3+ phosphors were synthesized by collaborators from National Taiwan University. Structural evolution reveals a crystal phase change with the incorporation...
-
ECG measurement in the bathtub - drl on one side of the bathtub, the other side of the bathtub is grounded and the system ground is grounded- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Experimental Study of the Influence of Noise Level on the Uncertainty Value in a Measurement System Containing an Analog-to-Digital Converter
Dane BadawczeFor newly developed measuring systems it is easy to estimate type B uncertainties based on the technical data of the measuring modules applied. However, it is difficult to estimate A type un-certainties due to the unknown type and level of interferences infiltrating into the measuring sys-tem. This is a particularly important problem for measurements...
-
The influence of external interference on AFM imaging, the use of a protective helmet
Dane BadawczeThis collection is of purely practical importance, showing how the presence of external disturbances can adversely affect the quality of imaging with an atomic force microscope. For this reason, it is also advisable to provide a link to a workshop-like study [1] as well as a huge number of commercial solutions available after entering the keyword "AFM...