Filtry
wszystkich: 1693
wybranych: 1124
-
Katalog
- Publikacje 1124 wyników po odfiltrowaniu
- Czasopisma 11 wyników po odfiltrowaniu
- Osoby 21 wyników po odfiltrowaniu
- Wynalazki 6 wyników po odfiltrowaniu
- Projekty 12 wyników po odfiltrowaniu
- Laboratoria 1 wyników po odfiltrowaniu
- Zespoły Badawcze 3 wyników po odfiltrowaniu
- Kursy Online 19 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 494 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: ELEKTRODY MEMBRANOWE
-
Studies on membrane scaling during water desalination by direct contact membrane distillation
Publikacja -
Polyphosphates used for membrane scaling inhibition during water desalination by membrane distillation
Publikacja -
Deep eutectic solvents – A new platform in membrane fabrication and membrane-assisted technologies
PublikacjaDeep eutectic solvents (DESs) are a new class of solvents that can offset some of the primary drawbacks of typical solvents and ionic liquids (ILs). Since DESs fall into the guidelines of “Twelve Principles of Green Chemistry”, their implementation in several types of applications has exponentially increased over the last years. The usage of DESs has been directed to the designing, manufacture and purification of new materials...
-
Zespolona elektroda stała do oznaczeń elektrochemicznych ze zwiekszona dokładnością.
PublikacjaW artykule przedstawiono nowe rozwiązanie elektrody stałej charakteryzujące się zmniejszoną wartością gradientu potencjału pola elektrycznego na powierzchni w stosunku do rozwiązań konwencjonalnych. Nowa konstrukcja zespolonej elektrody pomiarowej umożliwia zmniejszenie wartości jej prądu migracyjnego, a tym samym pozwala na poprawę dokładności prowadzonych oznaczeń elektrochemicznych.
-
Właściwości dynamiczne elektrody woltamperometrycznej w dziedzinie częstotliwości i koncepcja metody ich wyznaczenia
PublikacjaW artykule przeanalizowano zasadę pracy elektrody woltamperometrycznej. Z przeprowadznej analizy wynika, że elektroda woltamperometryczna w przypadku oznaczeń małych stężeń jest przetwornikiem I rzędu. Jej właściwości metrologiczne określa czułość, stała czasowa i częstotliwość graniczna. W artykule zaproponowano metodę pomiaru parametrów dynamicznych na podstawie pomiaru prądu granicznego reakcji elektrochemicznj przebiegajacej...
-
Zastosowanie destylacji membranowej do oczyszczania zaolejonych ścieków
Publikacja -
Zastosowanie destylacji membranowej do zatężania roztworów soli
Publikacja -
Electric field effect on luminescence, and photoconduction in electron donor - electron acceptor organic solid films
PublikacjaZaobserwowano silne wygaszenie fotoluminescencji (80%) i duże fotoprądy (1mA/cm2) w układzie dendrymer aminowy m-MTDATA (donor elektronu) : pochodna fenantroliny BPT (akceptor elektronu) niedomieszkowanym oraz zawierającym domieszkę w postaci organicznego kompleksu platyny PtL2Cl. W interpretacji wyników uwzględniono elektrycznopolową dysocjację singletowych ekscypleksów m-MTDATA:BPT i trypletowych ekscypleksów m-MTDATA : PtL2Cl...
-
Zastosowanie metody galwanostatycznej do wyznaczania błędu fazy elektrod woltamperometrycznych
PublikacjaW pracy przeanalizowano właściwości metrologiczne elektrod woltamperometrycznych w dziedzinie częstotliwości. Wykazano, że w przypadku, gdy reakcja elektrochemiczna kontrolowana jest procesem transportu jonów, elektroda woltamperometryczna zachowuje się tak jak przetwornik pomiarowy I rzędu. Jej właściwości metrologiczne opisane są przez czułość, częstotliwość graniczną, błąd amplitudy i błąd fazy. Przeprowadzona analiza pokazała,...
-
Wpływ konfiguracji elektrod pomiarowych oraz parametrów pomiaru na EDR
PublikacjaW pracy przebadano wplyw wybranych konfiguracji elektrod na jakość uzyskiwanego sygnału EDR. Analizie poddane zostały również częstotliwość próbkowania sygnału EKG i rozdzielczość przetwornika AC/DC. Optymalną konfiguracją elektrod jest odprowadzenie kończynowe pierwsze. Minimalne parametry układu pomiarowego do uzyskania wysokiej jakości sygnału EDR, to częstotliwość probkowania 2,5kHz oraz 14-bitowy przetwornik AC-DC.
-
Sonda do identyfikacji parametrów struktur warstwowych: optymalizacja kształtu elektrod.
PublikacjaPraca opisuje budowę sondy pierścieniowej do pomiaru elektrycznych parametrów tkanek biologicznych. Opisana jest metoda identyfikacji parametrów biologicznych struktur warstwowych. Zaproponowana została modyfikacja kształtu elektrod w celu optymalizacji rozkładu gęstości prądu poprawiająca powtarzalność pomiarów.
-
Charakterystyka areodynamiczna membranowego przekrycia wiszącego.
PublikacjaArtykuł przedstawia charakterystykę aerodynamiczną membranowego przekrycia wiszącego. Prezentowane są dwie koncepcje przyjmowania wartości współczynnika aerodynamicznego. Pierwsza z koncepcji bazuje bezpośrednio na testach laboratoryjnych druga zaś wykorzystuje uproszczone podejście normowe.This paper presents the aerodynamic characteristics of membrane hanging roof. The two concepts of taking the value of the aerodynamic factor...
-
Ionophores in polymeric membranes for selective ion recognition; impedance studies
PublikacjaBadania impedancyjne membran zawierających jonofory selektywne na kation Na+ (L1) i Cs+(L2) wykazały, ze stala dielektryczna materiału membrany zależy od typu uzytego plastyfikatora i zmienia się w zakresie od 28 do 60. Rezystancja membran zawierających ligand L1 i L2 wynosi 0.15 -1.4 Mohm w zależności od stężenia elektrolitu zewnnetrznego. Testowona dwa typy elektrod jonoselektywnych: elektrody typu ASS z polimerem przewodzącym...
-
Spektroskopia elektro-ultradźwiękowa warystorów wysokonapięciowych
PublikacjaPrzedstawiono nową nieniszczącą metodę wykrywania defektów dwójni-ków. W metodzie wykorzystuje się wzajemne oddziaływanie fononów ultradźwiękowych i elektronów wskutek istnienia defektu powodującego nieliniowości. Testowana próbka jest pobudzana przez sygnały harmo-niczne: elektryczny i ultradźwiękowy o różnych częstotliwościach. Wsku-tek nieliniowości powodowanej przez defekt struktury próbki powstaje nowy sygnał harmoniczny o...
-
Wastewater treatment by membrane distillation
Publikacja -
Membrane distillation with laminar flow
Publikacja -
Size-controlled synthesis of gold nanoparticles by a novel atmospheric pressure glow discharge system with a metallic pin electrode and a flowing liquid electrode
Publikacja -
Frequency dispersion of harmonic components of the current of an electrode process
Publikacja -
Fundamental-harmonic impedance of first-order electrode reactions
Publikacja -
Determination of electrode impedance by means of exponential chirp signal
Publikacja -
Carbon Based Electrode Materials and their Architectures for Capacitive Deionization
Publikacja -
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublikacjaThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublikacjaAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
VOLTAMMETRIC DETERMINATION OF DEOXYRIBONUCLEIC ACID PRESENCE ON A CARBON ELECTRODE
PublikacjaThis paper presents a voltammetry as a useful method to analyse DNA from different species. This electrochemical method is well know and used in different analyses. The influence of an area of working electrode and the capacity component, is shown at equals and the measurement. In voltammetry DNA measurement the capacity component is very important and must be taken into consideration. All mathematical analyses were verify at laboratory.
-
Investigation of Narrow Electrostatic Precipitator with Wire Multi-Electrode
PublikacjaDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are notenough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of interest...
-
Determination of electrode impedance by means of exponential chirp signal.
PublikacjaPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Jako pobudzenie zastosowany został niestacjonarny sygnał napięciowy, którego częstotliwość jest ekspotencjalną funkcją czasu. Zastosowanie zmodyfikowanej któtko-czasowej transformaty Fouriera (STFT) w analizie napięciowego pobudzenia i odpowiedzi prądowej pozwala na otrzymanie widma impedancyjnego.
-
Functionalization of electrode surfaces with monolayers of azocompounds and gold clusters.
PublikacjaWłaściwości monowarstw z azokoron na powierzchni złota były badane przy pomocy woltametrii i STM. Powierzchnia przypadająca na cząsteczkę została wyznaczona przy pomocy woltametrii i wynosi 0,65 nm kwadratowych. Wartość ta jest zgodna z wyznaczoną w oparciu o monowarstwę utworzoną na granicy powietrze-woda techniką Langmir-Blodgett. Tworzenie się klasterów złota i innych struktur obserwowano przy pomocy STM w przypadku gdy złota...
-
A probe for immittance spectroscopy based on the parallel electrode technique.
PublikacjaW pracy zaprezentowano konstrukcję sondy do spektroskopowych pomiarów immitancyjnych. Obliczono jej stałą, którą to wartość zweryfikowano eksperymentalnie. Pokazano przykładowe wyniki pomiarów in vivo.
-
The interference between electrode and poly(ethylene oxide) electrolytes
PublikacjaSpektroskopia impedancyjna zastosowana została do scharakteryzowania granicy faz elektroda-elektrolit poli(oksyetylenowy) zawierający sole litu. Udział rozpuszczalnika w pojemności wewnętrznej warstwy, Cs(σ), dla CH3(OCH2CH2 )nOCH3 DLA N=4,8,10 oraz dla PMEO [(CH2CH2O)mCH2O]m m=5-10 został wyznaczony z wartości pojemności warstwy sztywnej pomniejszonej o udział metalu CM. Wyznaczono wartość pojemności dipolowej Ci(dip) dla PEO...
-
An active electrode for mixed measurement techniqes, with application to EIT
PublikacjaW pracy przedstawiono budowę elektrody aktywnej wraz z opisem procedur pomiarowych prowadzących do poprawy stosunku sygnał-szum. Elektroda zbudowana jest w technice cyfrowo analogowej.
-
Spatial sensitivity to the conductivity changes of a four electrode probe.
PublikacjaW artykule rozważana jest czułość przestrzenna, czteropunktowej, liniowej sondy na zmiany przewodności zachodzące w badanym materiale. Otrzymane wyniki wskazują, że czułość może być zarówno dodatnia i ujemna, tzn. wzrost przewodności może prowadzić zarówno do wzrostu lub do spadku mierzonej impedancji. W artykule rozważane są materiały zarówno izotropowe jak i anizotropowe. Uzyskane wyniki pozwalają wyjaśnić dlaczego niektóre...
-
Koncepcja zwiększenia dokładności czujnika tlenu rozpuszczonego
PublikacjaW artykule przedstawiono modyfikację konstrukcji elektrochemicznego czujnika do pomiaru stężenia tlenu rozpuszczonego w wodzie. Modyfikacja opiera się na zastosowaniu dodatkowych elektrod w pobliżu elektrody pracującej czujnika. Takie rozwiązanie prowadzi do zmniejszenia gradientu potencjału pola elektrycznego na powierzchni elekrody pracującej i tym samym powoduje zmniejszenie prądu migracyjnego czujnika, która jest główną składową...
-
Sposób poprawy własności dynamicznych czujników konduktometrycznych.
PublikacjaW artykule przeanalizowano wpływ mechanizmu transportu migracyjnego jonów na własności dynamiczne czujników konduktometrycznych. Pokazano, że czujniki te są przetwornikami pierwszego rzędu i ich właściwości dynamiczne determinowane są przez ich budowę. Zaproponowano modyfikację konstrukcji tych czujników poprzez wprowadzenie dodatkowej elektrody polaryzacyjnej. Elektroda ta zwiększa gradient potencjału pola elektrycznego na powierzchni...
-
Pomiary ilości wodoru dyfundującego w stopiwie elektrod celulozowych i zasadowych
PublikacjaW artykule scharakteryzowano technologię wytwarzania złączy poprzecznych rurociągów energetycznych w aspekcie kontroli ilości wodoru dyfundującego. Oznaczono zawartość wodoru dyfundującego w stopiwie dla złączy wielościegowych wykonanych elektrodami o otulinie celulozowej i zasadowej. Ustalono, że po wykonaniu 4 ściegów ilość wodoru dyfundującego spada z około 40 ml/100 g do poziomu 12 ml/100 g i zaproponowano wyjaśnienie mechanizmów...
-
Elektroda stała do oznaczeń elektrochemicznych ze zmniejszonym gradientem potencjału pola elektrycznego.
PublikacjaPrzedstawiono nowe rozwiązanie elektrody stałej, która charakteryzuje się zmniejszoną wartością gradientu potencjału elektrycznego ne jej powierzchni w stosunku do rozwiązań konwencjonalnych. Umożliwia to zmniejszenie wartości prądu migracyjnego rejestrowanego podczas oznaczeń elektrochemicznych, który jest jedną ze składowych zakłócających, a tym samym poprawę dokładności prowadzonych oznaczeń elektrochemicznych.
-
Hybrid biobattery based on arylated carbon nanotubes and laccase
PublikacjaJednościenne nanorurki węglowe modyfikowano resztami antracenu i antrachinonu Otrzymany materiał posłużył do modyfikacji elektrody węglowej w celu jej zastosowania do redukcji tlenu w bioogniwie paliwowym. Nanorurki z aromatycznymi grupami zwiększyły powierzchnię elektrody oraz przyczyniły się do zwiększenia bezpośredniego przeniesienia elektronów. Grupy arylowe mogą wnikać do hydrofobowej kieszeni enzymu, w której znajduje się...
-
Desalination of geothermal water by membrane distillation
Publikacja -
Water Purification by Membrane Distillation Process
Publikacja -
The fermentation process integrated with membrane distillation
Publikacja -
Capillary Polypropylene Membranes for Membrane Distillation
Publikacja -
Ethanol production in membrane distillation bioreactor
Publikacja -
Heat transport in the membrane distillation process
Publikacja -
The Application of Submerged Modules for Membrane Distillation
Publikacja -
Bilge water separation by membrane distillation
Publikacja -
Study on the concentration of acids by membrane distillation
Publikacja -
Alkaline scaling in the membrane distillation process
Publikacja -
Progress in module design for membrane distillation
PublikacjaThere have been tremendous advances in membrane distillation (MD) since the concept was introduced in 1961: new membrane designs and process configurations have emerged, and its commercial viability has been evaluated in several pilot-scale studies. However, its high energy consumption has hindered its commercialization. One of the most promising ways to overcome this obstacle is to develop more energy-efficient membrane modules....
-
Modeling bioaugmentation with nitrifiers in membrane bioreactors
PublikacjaBioaugmentation with nitrifiers was studied using two pilot-scale membrane bioreactors, with the purpose of assessing the suitability of state-of-the-art activated sludge models (ASMs) in predicting the efficiency of bioaugmentation as a function of operating conditions. It was demonstrated that the temperature difference between seeding and seeded reactors (ΔT) affects bioaugmentation efficiency. Experimental data were accurately...
-
Fast method for the determination of the charge transfer coefficient of an electrode reaction
Publikacja -
Paraxial parameters and aberration of seven-electrode axisymmetric cathodic lens
Publikacja