Filtry
wszystkich: 4104
-
Katalog
- Publikacje 2684 wyników po odfiltrowaniu
- Czasopisma 77 wyników po odfiltrowaniu
- Konferencje 13 wyników po odfiltrowaniu
- Osoby 60 wyników po odfiltrowaniu
- Wynalazki 3 wyników po odfiltrowaniu
- Projekty 5 wyników po odfiltrowaniu
- Laboratoria 1 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 86 wyników po odfiltrowaniu
- Dane Badawcze 1174 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: CHIRP SIGNAL
-
Guided wave propagation signals measured on corroded stiffened panels
Dane BadawczeThe fundamental antisymmetric Lamb mode was excited by piezoelectric transducers attached at the pre-selected points on stiffened panels, representing typical structural ship components. The specimens were exposed to accelerated marine corrosion degradation, so the signals were collected to analyze the influence of the degree of degradation on the wave...
-
Wave propagation signals for ultrasonic tomography of concrete during splitting
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube with dimensions 70 x 70 x 70 cm3under the splitting test. Three cubes were tested: cube 1 (concrete with polymer fibres), cube 2 (concrete with steel fibres) and cube 3 (plain concrete).
-
Michał Mazur dr inż.
OsobyAktualne zainteresowania inżynieria mechaniczna, robotyka, drgania mechaniczne, analiza modalna, sterowanie, systemy czasu rzeczywistego Wybrane publikacje Kaliński K., Galewski M., Mazur M., Chodnicki M, 2017, Modelling and Simulation Of A New Variable Stiffness Holder for Milling Of Flexible Details, Polish Maritime Research, vol 24, ss. 115-124 Kaliński K. J., Mazur M.: Optimal control at energy performance index of the mobile...
-
The ear as a location for wearable vital signs monitoring
Publikacja -
Akaike's final prediction error criterion revisited
PublikacjaWhen local identification of a nonstationary ARX system is carried out, two important decisions must be taken. First, one should decide upon the number of estimated parameters, i.e., on the model order. Second, one should choose the appropriate estimation bandwidth, related to the (effective) number of input-output data samples that will be used for identification/ tracking purposes. Failure to make the right decisions results...
-
Museums of Gdansk - Tourism Products or Signs of Remembrance?
PublikacjaMuseum buildings constitute a significant element in the composition and functionality of contemporary cities. They are both their attractions and landmarks. The article presents a case study illustrating the relation between museum buildings and their location, as well as the showcased exhibition. The article aims at demonstrating the way in which those elements form a harmonious whole - a cultural tourism product affecting the...
-
Effect of Double-Slope Modulation Signals on Conducted Emissions and Efficiency of Strongly Coupled Magnetic Resonance WPT Systems
Publikacja -
Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
PublikacjaThe aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development...
-
Modeling of TEC Variations Based on Signals from Near Zenith GNSS Satellite Observed by Dense Regional Network
PublikacjaCurrently the substantial successes in high-resolution ionospheric mapping is declared in many publications. Nevertheless, up to now there are no examples of dynamic visualization of TEC disturbances on regional scale with as high resolution as tropospheric models. Over the years, ionosphere has been modeling basing on the simple assumption, that it is a thin layer, which surrounds the Earth at some arbitrary height. However, the...
-
A pilot study to assess manufacturing processes using selected point measures of vibroacoustic signals generated on a multitasking machine
PublikacjaThe article presents the method for the evaluation of selected manufacturing processes using the analysis of vibration and sound signals. This method is based on the use of sensors installed outside the machining zone, allowing to be used quickly and reliably in real production conditions. The article contains a developed measurement methodology based on the specific location of microphones and vibration transducers mounted on...
-
Analogue GPS repeater
PublikacjaThis article concerns the problem of difficulty in correct indoor Global Positioning System (GPS) signals reception due to attenuation. Radio signal repeaters are proposed as means to solve this problem. Firstly, the GPS signal characteristics are described, emphasizing their low power in the point of reception. In the second part, various applications of GPS signal repeater, where indoor GPS signals reception is required, are...
-
Jacek Stefański prof. dr hab. inż.
OsobyJacek Stefański ukończył studia na Wydziale Elektroniki Politechniki Gdańskiej (PG) w 1993 r. W 2000 r. uzyskał stopień doktora nauk technicznych w dyscyplinie telekomunikacja, w 2012 r. stopień doktora habilitowanego, natomiast w 2020 r. tytuł profesora nauk inżynieryjno-technicznych. Obecnie pracuje na stanowisku profesora w Katedrze Systemów i Sieci Radiokomunikacyjnych (KSiSR) PG. W latach 2005-2009 był zatrudniony w Instytucie...
-
Various approaches to a human preference analysis in a digital signage display design
Publikacja -
Optimization of ASE Conditions for the HPLC Determination of Rutin and Isoquercitrin inSambucus nigraL
Publikacja -
Fast rns scaling of signed numbers based on the chinese remainder theorem
PublikacjaPrzedstawiono architekturę szybkiego skalera resztowego dla liczb ze znakiem dla modułów 5-bitowych opartego na chińskim twierdzeniu o resztach. W architekturze zastosowano wyznaczanie projekcji ortogonalnych przy użyciu funkcji logicznych 5 zmiennych, sumator kodulo m/k oraz wejściowy konwerter do systemu resztowego. Operacja modulo m/k jest wykonywana przy zastosowaniu drzewa 4-operandowych sumatorów modulo 2m/k i końcowego...
-
Цифровой анализ сигналов речи как инструмент сравнительного языкознания [A digital analysis of speech signals as an instrument in comparative linguistics]
Publikacja -
Zbigniew Czaja dr hab. inż.
OsobyZbigniew Czaja was born in Czluchow, Poland, in 1970. He graduated from Gdansk University of Technology, Faculty of Electronics, Telecommunications and Informatics in 1995. The Ph.D. degree in electronics was received in 2001 from the same university. He worked as assistant professor at this university from 2002 to 2013. In 2014, he qualified as an associate professor, and in 2017, as a professor. His research interests are in...
-
Fixed final time and free final state optimal control problem for fractional dynamic systems – linear quadratic discrete-time case
Publikacja -
Wave propagation signals in concrete beams under 3-point bending
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete beams with dimensions 40 x 40 x 160 cm3under the 3-point bending. The beams were made of concrete with the following ingredients: CEM I 42.5R (450 kg/m3), water (177 kg/m3), sand 0-2 (675 kg/m3) and gravel 2-8 (675 kg/m3). The bending test was performed using a Zwick/Roell Z10...
-
POSSIBILITY OF ASSESSMENT OF OPERATION OF SLIDING BEARINGS IN PISTON-CRANK MECHANISMS OF DIESEL ENGINES WITH REGARD TO LOAD AND TIME OF CORRECT WORK OF THE BEARINGS BY APPLYING ACOUSTIC EMISSION AS A DIAGNOSTIC SIGNAL
PublikacjaAbstract: The paper presents a possibility of determining (assessing) operation of sliding bearings with multilayer bushings in crank-piston mechanisms of diesel engines. Properties of load and wear, particularly fatigue and abrasive, are characterized in general. Acoustic emission as a diagnostic signal was proved to be useful for detection of the wear of sliding and barrier layers. Results of measurements of acoustic emission...
-
Germline DNA Retention in Murine and Human Rearranged T Cell Receptor Gene Coding Joints: Alternative Recombination Signal Sequences and V(D)J Recombinase Errors
Publikacja -
MICROSEISMIC EVENT DETECTION USING DIFFERENT ALGORITHMS ON REAL DATA FROM PATCH ARRAY GEOPHONE GRID FROM EASTERN POMERANIA FRACTURING JOB
PublikacjaThe microseismic monitoring is a method of monitoring of fracture propagation during hydraulic fracturing process. Hydraulic fracturing is a method of reservoir stimulation used especially for unconventional gas recovery. A matrix of several thousand geophones is placed on the surface of earth to record every little tremor of ground induced by fracturing process. Afterwards, the signal is analysed and the place of tremor occurrence...
-
JOURNAL OF RECEPTORS AND SIGNAL TRANSDUCTION
Czasopisma -
Signal Image and Video Processing
Czasopisma -
Topics in Spinal Cord Injury Rehabilitation
Czasopisma -
Sirnak University Journal of Divinity Faculty
Czasopisma -
Improving Objective Speech Quality Indicators in Noise Conditions
PublikacjaThis work aims at modifying speech signal samples and test them with objective speech quality indicators after mixing the original signals with noise or with an interfering signal. Modifications that are applied to the signal are related to the Lombard speech characteristics, i.e., pitch shifting, utterance duration changes, vocal tract scaling, manipulation of formants. A set of words and sentences in Polish, recorded in silence,...
-
Final state of thermal evolution of Jupiter-type planet
Publikacja -
Pathomorphology of the Liver in Dogs with Clinical Signs of Portosystemic Shunts
Publikacja -
Comment on "Measurements without probabilities in the final state proposal"
PublikacjaThe final state proposal [G.T. Horowitz and J.M. Maldacena, J. High Energy Phys.2004(2),8 (2004)] is an attempt to relax the apparent tension betweenstring theory and semiclassicalarguments regarding the unitarity of black hole evaporation. The authors of [R. Bousso and D.Stanford, Phys. Rev. D89, 044038 (2014)] analyze thought experiments where an infalling observerfirst verifies the entanglement between early and late Hawking...
-
MOUNT SINAI JOURNAL OF MEDICINE
Czasopisma -
A fast time-frequency multi-window analysis using a tuning directional kernel
PublikacjaIn this paper, a novel approach for time-frequency analysis and detection, based on the chirplet transform and dedicated to non-stationary as well as multi-component signals, is presented. Its main purpose is the estimation of spectral energy, instantaneous frequency (IF), spectral delay (SD), and chirp rate (CR) with a high time-frequency resolution (separation ability) achieved by adaptive fitting of the transform kernel. We...
-
Sparse autoregressive modeling
PublikacjaIn the paper the comparison of the popular pitch determination (PD) algorithms for thepurpose of elimination of clicks from archive audio signals using sparse autoregressive (SAR)modeling is presented. The SAR signal representation has been widely used in code-excitedlinear prediction (CELP) systems. The appropriate construction of the SAR model is requiredto guarantee model stability. For this reason the signal representation...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...