Filtry
wszystkich: 1311
-
Katalog
- Publikacje 656 wyników po odfiltrowaniu
- Czasopisma 7 wyników po odfiltrowaniu
- Osoby 11 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 18 wyników po odfiltrowaniu
- Wydarzenia 18 wyników po odfiltrowaniu
- Dane Badawcze 597 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: NEMI
-
Mechanical analysis of eccentric defected bilayer graphene sheets considering the van der Waals force
PublikacjaIn this article, we have tried to simulate nonlinear bending analysis of a double-layered graphene sheet which contains a geometrical imperfection based on an eccentric hole. The first-order shear deformation theory is considered to obtain the governing equations. Also, the nonlinear von Kármán strain field has been assumed in order to obtain large deformations. Whereas the double-layered graphene sheet has been considered, the...
-
Multiparameter sensitivity analysis of a GFRP composite footbridge of a sandwich structure and U-shaped cross-section
PublikacjaThe paper deals with multiparameter sensitivity analysis of a composite footbridge. A shell‐like structure is 14.5 m long shows U‐shaped cross‐section and inner service dimensions 1.3 × 2.5 m. Glass fiber reinforced polymer GFRP laminate constitutes faces of a sandwich structure while PET foam received from recycled bottle builts a core. The structure was divided into 285 independent areas where the thickness of laminates and stiffness...
-
Tailoring optical constants of few-layer black phosphorus coatings: Spectroscopic ellipsometry approach supported by ab-initio simulation
Publikacja2D black phosphorus (BP) has attracted extensive attention as an anisotropic platform for novel optoelectronic and polarizing optics applications. Insight into the factors that tune the optical and polarizing properties of 2D BP reveals their essential influence on BP-based photonic and optoelectronic devices. In this work, studies of the optical constants of few-layer black phosphorus coatings are studied and discussed, with particular...
-
Time-Gating method with automatic calibration for accurate measurements of electrically small antenna radiation patterns in Non-Anechoic environments
PublikacjaNon-anechoic sites represent a cheap alternative to measurements of antennas in dedicated facilities. However, due to a high noise—from the external EM signal sources and multipath interferences—the quality of radiation patterns obtained in non-anechoic conditions is poor. The characteristics can be corrected using a time-gating method (TGM), which involves filtering of the noise based on temporal analysis of the measured signals....
-
Comparison of predictive methods for flow boiling heat transfer in conventional channels and minichannels - the effect of reduced pressure
PublikacjaIn the paper are presented the results of follow on studies from [1]–[3] using authors own model to predict heat transfer coefficient during flow boiling. The model has been tested against a large selection of experimental data collected from various researchers to investigate the sensitivity of the in-house developed model. The collected experimental data came from various studies from literature and were conducted for the full...
-
Low cost set-up for supercapacitors parameters evaluation
PublikacjaSupercapacitors are capable to store relatively high amount of energy comparing to its mass. Growing number of these devices applications requires development of new testing methods. Standard methods of evaluation of supercapacitor parameters, as cycling voltammetry, CV, galvanostatic cycling with potential limitation, GCPL, impedance measurements, require equipment of high cost...
-
ANALIZA PRZEBIEGÓW ZMIAN TEMPERATURY CZYNNIKA ROBOCZEGO W CYLINDRZE ORAZ KANALE SPALIN WYLOTOWYCH SILNIKA O ZS DLA POTRZEB DIAGNOSTYCZNYCH - STAN BADAŃ
PublikacjaCharakter przebiegów zmian ciśnienia i temperatury czynnika roboczego w silniku o zapłonie samoczynnym jest istotnym źródłem informacji diagnostycznych. Pozwalają na analizę stanu technicznego zarówno aparatury paliwowej jak i układu cieplno - przepływowego. Dotyczy to zarówno temperatury i ciśnienia gazów w czasie całego cyklu pracy silnika o ZS wewnątrz cylindra, jak i tych samych parametrów dotyczących spalin, rejestrowanych...
-
Safety integrity level verification for safety-related functions with security aspects
PublikacjaThe article is devoted some important issues of the functional safety analysis, in particular the safetyintegrity level (SIL) verification of safety functions to be implemented within the distributed controland protection systems with regard to cyber security aspects. The procedure for functional safety man-agement includes hazard identification, risk analysis and assessment, specification of overall safetyrequirements and definition...
-
Optimal control at energy performance index of the mobile robots following dynamically created trajectories
PublikacjaIn practice, the problem of motion control of the wheeled mobile robots is often neglected. Wheeled mobile robots are strongly nonlinear systems and restricted by non-holonomic constraints. Motion control of such systems is not trivial task and usage of non-optimal control signals can lead to deterioration of the overall robot system’s performance. In case of autonomous application of the mobile robots all parts of its control...
-
Comparison of Surface Quality and Tool-Life of Glulam Window Elements after Planing
PublikacjaThe quality of the surface of wooden elements, that have been planed, has a crucial importance in the whole production process, since the obtained effects affect the quality of wooden surface after fi nishing (painting). The occurrence of defects is usually the reason for qualifying a workpiece as scrap or for requiring additional work. This paper presents the selected results of research of the effect of the cutting tool wear...
-
Jak wykraść złoto smokowi? - uczenie ze wzmocnieniem w świecie Wumpusa
PublikacjaNiniejszy rozdział zawiera łagodne wprowadzenie do problematyki uczenia ze wzmocnieniem, w którym podstawy teoretyczne wyjaśniane są na przykładzie przewodnim, jakim jest zagadnienie nauczenia agenta poruszania się w świecie potwora o imieniu Wumpus (ang. Wumpus world), klasycznym środowisku do testowania logicznego rozumowania agentów (problem nietrywialny dla algorytmów uczenia ze wzmocnieniem). Przedstawiona jest główna idea...
-
MRI-Derived Subcutaneous and Visceral Adipose Tissue Reference Values for Children Aged 6 to Under 18 Years
PublikacjaThe assessment of body composition in pediatric population is essential for proper nutritional support during hospitalization. However, currently available methods have limitations. This study aims to propose a novel approach for nutrition status assessment and introduce magnetic resonance imaging (MRI)-derived subcutaneous and visceral fat normative reference values. A total of 262 healthy subjects aged from 6 to 18 years underwent...
-
Dynamic control of the receiving beam horizontal cross-section in the side scan sonar
PublikacjaW skonstruowanych przed kilkunastu laty a obecnie modernizowanych sonarach bocznych jako jeden z zabiegów modernizacyjnych wprowadzono dynamiczną regulację kąta rozwarcia odbiorczej charakterystyki kierunkowej w przekroju horyzontalnym. Regulacja taka zapewnia quasi-stałą rozdzielczość liniową sonaru (zamiast stałej rozdzielczości kątowej) przy odbiorze sygnałów echa ze wzrastających odległości od wykrywanych celów. W efekcie tego...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Blue nevus, NOS - Male, 42 - Tissue image [6130730026867861]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma, metastatic - Female, 80 - Tissue image [6060730023674341]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Spitz nevus, NOS - Male, 19 - Tissue image [8160730027014441]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The AFM topographic measurements of the surface heterogeneity of iron hexacyanoferrate on a steel surface
Dane BadawczeMeasurements in semi-contact mode. NTEGRA Prima (NT-MDT) device. NSG 01 probe.
-
Spitz nevus, NOS - Female, 26 - Tissue image [7110729594545301]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma, metastatic - Male, 63 - Tissue image [9140730014151181]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 51 - Tissue image [626073002189591]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dermal nevus - Male, 64 - Tissue image [6200730021568631]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dermal nevus - Female, 53 - Tissue image [6200730021573071]
Dane BadawczeThis is the histopathological image of VULVA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Compound nevus - Female, 28 - Tissue image [6300730028271671]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intradermal nevus - Female, 58 - Tissue image [6300730028278271]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Compound nevus - Male, 36 - Tissue image [6300730028276941]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Male, 33 - Tissue image [7040247104938751]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dermal nevus - Female, 19 - Tissue image [6200730021568441]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma, metastatic - Male, 63 - Tissue image [5300730025864691]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Intradermal nevus - Female, 38 - Tissue image [11020630022695541]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intradermal nevus - Female, 58 - Tissue image [630073002827471]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dermal nevus - Female, 31 - Tissue image [6200730021564841]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma, metastatic - Male, 63 - Tissue image [914073001415571]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Compound nevus - Male, 36 - Tissue image [6300730028272411]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Spitz nevus, NOS - Male, 21 - Tissue image [7130729588541601]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma, metastatic - Male, 63 - Tissue image [5300730025861381]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Dermal nevus - Male, 42 - Tissue image [6200730021569871]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Intradermal nevus - Female, 57 - Tissue image [6300730028271761]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Compound nevus - Female, 41 - Tissue image [6170730026748031]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dermal nevus - Female, 24 - Tissue image [6200730021567821]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Spitz nevus, NOS - Female, 24 - Tissue image [6250730010627701]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma in situ - Unknown, 65 - Tissue image [330073006939971]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Compound nevus - Male, 36 - Tissue image [6300730028279371]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma, metastatic - Male, 63 - Tissue image [9140730014159831]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Female, 35 - Tissue image [6060730023677431]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma, metastatic - Female, 80 - Tissue image [6060730023676671]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Dermal nevus - Male, 24 - Tissue image [6200730021564981]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma in situ - Unknown, 65 - Tissue image [3300730069391101]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Melanoma, metastatic - Male, 73 - Tissue image [10130730023082601]
Dane BadawczeThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Blue nevus, NOS - Male, 66 - Tissue image [6300730028266321]
Dane BadawczeThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.