prof. dr hab. inż. Zbigniew Lubośny
Zatrudnienie
- Profesor w Katedra Elektroenergetyki
Publikacje
Filtry
wszystkich: 137
Katalog Publikacji
Rok 2020
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublikacjaCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublikacjaThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
Oversizing the photovoltaic generator capacity in a micro photovoltaic plant
PublikacjaA significant part of photovoltaic micro installations in Poland is characterized by photovoltaic generator oversizing in relation to the inverter. The idea of oversizing, however, still raises doubts among some plant owners. In the paper, the energy yield of installation with an oversized and not oversized photovoltaic generator is presented on selected examples, showing the legitimacy of oversizing.
-
Power System Dynamics. Stability and Control. 3rd edition
PublikacjaComprehensive, state-of-the-art review of information on the electric power system dynamics and stability. It places the emphasis first on understanding the underlying physical principles before proceeding to more complex models and algorithms. The book explores the influence of classical sources of energy, wind farms and virtual power plants, power plants inertia and control strategy on power system stability. The book cover...
-
Virtual inertia in Electric Power System
PublikacjaThe article presents the idea of introducing virtual inertia system to the electric power systems. The virtual inertia aim is to reduce or eliminate the effect of reducing the inertia of the power system as a result of replacing classic electricity generating units with renewable renergy sources (RES). The considerations are ilustrated by a computational example.
Rok 2019
-
Cross-Bonding of MV Cable Lines for Energy Losses Decrease
PublikacjaCurrently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses...
-
Energy losses reduction in the medium voltage cable line – case study
PublikacjaThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Hydro Power Plant in the Process of Voltage Control in the Electric Power System and the System Restoration
PublikacjaThe article covers selected issues related to the share of hydroelectric power in the process of rebuilding the power system after black-out and voltage control during that process. Selected results of measurements made during the creation of the transmission chain for the need to start a block of a thermal power plant from a hydroelectric power plant were presented.
-
Modelling of MV and HV Cable Lines
PublikacjaOverhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....
-
Uproszczone modelowanie linii kablowych wysokiego napięcia a napięcia indukowane w żyłach powrotnych – studium przypadku
PublikacjaLinie kablowe, obok linii napowietrznych, są jednym z podstawowych elementów składowych systemów elektroenergetycznych. Stosowane są głównie na terenach zurbanizowanych, gdzie prowadzenie linii napowietrznych jest mocno utrudnione lub wręcz niemożliwe. Linie kablowe wysokiego napięcia budowane są głównie z wykorzystaniem kabli, które oprócz żyły roboczej mają również współosiową żyłę powrotną. Istnieje kilka układów pracy takich...
-
Wpływ wirtualnej inercji na system elektroenergetyczny
PublikacjaW referacie omówiono problem wpływu ubytku inercji naturalnej na stabilność częstotliwościową systemu elektroenergetycznego oraz ideę wirtualnej inercji. Przedstawiono struktury komercyjnych układów wirtualnej inercji. Zaprezentowano przykład wpływu układu wirtualnej inercji na właściwości dynamiczne systemu elektroenergetycznego.
Rok 2018
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublikacjaIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
Delivery of Ancillary Services in Distribution Power Systems
PublikacjaOne of the technical and organizational challenges the power system faces in deregulated market conditions is to organize an ancillary services market. The growing share of distributed generation of variable (intermittent) energy sources and a change in the market position of consumers, causes the demand for distributed delivery of ancillary services. For this purpose, it is sought to use the ability of the regulatory measures:...
-
Stabilność systemu elektroenergetycznego
PublikacjaKsiążka na 900 stronach prezentuje w sposób dogłębny zagadnienia związane ze stabilnością systemów elektroenergetycznych.
-
Wirtualna inercja w systemie elektroenergetycznym
PublikacjaW referacie omówiono problem wpływu ubytku inercji naturalnej na stabilność częstotliwościową systemu elektroenergetycznego oraz ideę wirtualnej inercji. Przedstawiono struktury komercyjnych układów wirtualnej inercji. Zaprezentowano przykład wpływu układu wirtualnej inercji na właściwości dynamiczne systemu elektroenergetycznego.
Rok 2017
-
Analiza napięć indukowanych i strat mocy w kablach elektroenergetycznych wysokiego napięcia dla wybranych sposobów uziemienia żył powrotnych
PublikacjaDostarczanie mocy do centrów miast coraz częściej odbywa się z wykorzystaniem linii kablowych o napięciu 110 kV. To dogodny sposób zasilania, a praktycznie jedyny możliwy w przypadku gęstej zabudowy miejskiej. Kable wysokiego napięcia zawierają współosiową żyłę powrotną, w której podczas normalnej pracy oraz w stanach zakłóceniowych (podczas zwarć) mogą indukować się znaczne napięcia względem ziemi, co zagraża porażeniem i/lub...
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia dla ich wybranych konfiguracji
PublikacjaW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia w wybranych konfiguracjach ich ułożenia
PublikacjaW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Identification of the customer meter assignment to phases in LV grid: Selected issues of UPGRID project realization
PublikacjaThe paper presents selected issues on the European UPGRID grant implemented by a consortium of companies from seven European states, including from Poland, on the monitoring and control of low voltage grid using measurement pre-registered data by smart AMI meters. The paper focuses on the issue of lack of information on the assignment of communal meters to individual phases.
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublikacjaPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Neutral earthing reactor protection
PublikacjaThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
Problemy pracy zabezpieczeń odległościowych linii 400 kV w Polsce północno-wschodniej
PublikacjaPrzedstawiono analizę wpływu połączenia polskiego systemu elektroenergetycznego z systemem Litwy na detekcję zakłóceń przez zabezpieczenia odległościowe linii 400 kV znajdujących się w najbliższym otoczeniu stacji Ełk Bis.
-
Projekt UPGRID
PublikacjaMiędzynarodowy projekt UPGRID realizowany jest w ramach programu Horyzont 2020 (H2020). Program ten to największy jak dotąd program Unii Europejskiej (UE) w zakresie badań naukowych i innowacji. W projekcie UPGRID uczestniczy 17 partnerów z 9 krajów EU. Głównym celem projektu UPGRID jest rozwój funkcjonalności, które służą integracji sieci nn oraz SN ze stroną konsumencką. W ramach projektu wybrane technologie Inteligentnych Sieci...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Resonance problems in UHV transmission lines
PublikacjaThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
The impact of the distribution network reconfiguration on active power losses: Selected issues of UPGRID project realization
PublikacjaThe dynamic development of smart grids allows the use of remote controllable switches to change the configuration of the distribution network. The paper discusses the impact of the distribution system reconfiguration on active power losses, taking into account the typical daily load profiles. Based on modified IEEE 33-bus test distribution system the article presents the method of selection the appropriate sensitivity factor and...
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
Wybrane problemy detekcji zakłóceń w dławiku uziemiającym przyłączonym do punktu gwiazdowego dławika kompensacyjnego
PublikacjaW referacie przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Przedstawiono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Wykorzystanie infrastruktury systemu ami w monitorowaniu i sterowaniu sieciami niskiego napięcia
PublikacjaW referacie przedstawiono wybrane zagadnienia z prac prowadzonych w ramach europejskiego grantu UPGRID realizowanego przez konsorcjum firm z siedmiu państw europejskich, w tym również z Polski, który dotyczy między innymi optymalizacji pracy sieci niskiego napięcia przy wykorzystaniu danych z liczników AMI.
-
Wykorzystanie liczników AMI w procesie optymalizacji pracy sieci niskiego napięcia
PublikacjaPrezentowany jest opis projektu dotyczącego m.in. optymalizacji pracy sieci niskiego napięcia przy wykorzystaniu danych z liczników AMI. Prace były prowadzone w ramach europejskiego grantu UPGRID, realizowanego przez konsorcjum firm z siedmiu państw europejskich, w tym również z Polski.
-
Zabezpieczanie dławika uziemiającego przyłączonego do punktu gwiazdowego dławika kompensacyjnego wysokiego napięcia
PublikacjaW artykule przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Załączono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015 roku, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Zjawiska rezonansowe a praca zabezpieczeń nadprądowych dławików kompensacyjnych linii wysokiego napięcia
PublikacjaW referacie prezentowany jest opis działania zabezpieczeń nadprądowych dławików kompensacyjnych zainstalowanych w linii Ełk Bis – Alytus, jakie miało miejsce w grudniu 2015 r. W efekcie działania zabezpieczeń nastąpiło zbędne wyłączenie dwóch dławików. Referat wyjaśnia przyczyny zaistniałej sytuacji prezentując analizę matematyczną, wyniki symulacji komputerowej oraz dane z rejestratorów zakłóceń.
Rok 2016
-
Calculations of Short-Circuit Current Flows in Earth Wires of HV Lines
PublikacjaThis paper presents a method which enables calculating flows of short-circuit currents in earth wires of high voltage transmission lines, and its implementation in the form of a computer programme. The algorithm enables performing calculations for a double-fed line and starconnected lines (three terminal lines). The developed programme enables verifying dimensioning of earth wires in the context of their short-circuit thermal withstand...
-
Computer-aided analysis of resonance risk in power system with Static Var Compensators
PublikacjaStatic Var Compensators operation in a power system may significantly improve voltage profiles in nodes and the reactive power balance, as well as ensure greater system stability in emergency conditions. However these devices may be a cause of a resonance in the system. The aim of this paper is to call attention to the need to include resonance phenomena in a compensator’s location evaluation process. The analysis performed in...
-
Elektrownie wiatrowe a stabilność systemu Elektroenergetycznego
PublikacjaW pracy omówiono problematykę wpływu elektrowni wiatrowych na system elektroenergetyczny. Rozważano zagadnienia związane z pewnością generacji, rezerwowaniem mocy czynnej, regulacją napięcia i mocy, jakością energii, stabilnością napięciową, stabilnością lokalną, stabilnością globalną, zdolnością do uczestnictwa w obronie i odbudowie systemu elektroenergetycznego, itd.
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublikacjaIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Power and energy measurement problems in transmission line between Poland-Lithuania
PublikacjaThe paper discusses problem of power and energy metering in double circuit overhead transmission line. Considerations are based on example of transmission line connecting Polish substation Bis Elk and Lithuanian substation Alytus.
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublikacjaThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Problemy pomiarów mocy i energii w linii elektroenergetycznej Polska-Litwa
PublikacjaW referacie przedstawiono zagadnienia związane z pomiarem mocy i energii w linii dwutorowej. Rozważania oparto na linii łączącej stacje elektroenergetyczne Ełk Bis i Alytus.
-
Problemy pracy zabezpieczeń odległościowych linii 400 kV w Polsce północno-wschodniej
PublikacjaW roku 2015 oddano do użytku połączenie polskiego systemu elektroenergetycznego z systemem elektroenergetycznym Litwy. Połączenie to zrealizowano z wykorzystaniem dwutorowej linii napowietrznej 400 kV Ełk Bis – Alytus oraz łącza back-to-back (BtB). W artykule przeanalizowano wpływ realizacji nowego połączenia, a tym samym zmianę konfiguracji sieci 400 kV, na detekcję zakłóceń przez zabezpieczenia odległościowe linii 400 kV znajdujących...
-
Zjawiska rezonansowe a praca zabezpieczeń nadprądowych dławików kompensacyjnych linii wysokiego napięcia
PublikacjaZaprezentowano opis działania zabezpieczeń nadprądowych dławików kompensacyjnych zainstalowanych w linii Ełk Bis - Alytus, jakie miało miejsce w grudniu 2015 r. W efekcie działania zabezpieczeń nastąpiło zbędne wyłączenie dwóch dławików. Referat wyjaśnia przyczyny zaistniałej sytuacji prezentując analizę matematyczną, wyniki symulacji komputerowej oraz dane z rejestratorów zakłóceń.
Rok 2015
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Effectiveness of the robust PSS design
PublikacjaThe paper discusses optimal PSS of synchronous generator synthesis. The optimal controller is an Hinf controller, what means that minimises Hinf norm of transfer function between the exogenous signals such as reference inputs and disturbances, and the error signals which are to be minimised to meet the control objective. The dynamic properties of the plant are shaped by choosing appropriate weighting function applied to the plant...
-
EHV transmission lines wires location on line operation issues - case studies
PublikacjaTransmission lines towers construction affects the line parameters and influences on its operation in the future. Misguided design of the tower can lead to serious problems such as overvoltages, electric arc extinction difficulties, voltage asymmetry, resonance phenomena or increasing of magnetic field near the line. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors....
-
Ekspertyza : Mapa rozwoju dyscypliny Elektrotechnika : Systemy Elektroenergetyczne
PublikacjaW publikacji przedstawiono trendy rozwojowe dyscypliny elektrotechnika opracowanej przez Komitet Elektrotechniki PAN.
-
Fractional-order Systems and Synchronous Generator Voltage Regulator
PublikacjaModern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using...
-
Induced sheath voltages in 110 kV power cables – case study
PublikacjaThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Influence of Shunt Compensation with SVC Devices on Resonance Risk in Power Systems
PublikacjaMany analyses are required to locate a new reactive power source in a power system. The choice of a location is a very complex matter which requires various aspects to be considered. Selecting a location also entails the necessity to assess it from the point of view of the selected compensator’s structure as well as the system’s performance in various states with the new device on. The paper presents the issues of assessing compensator...
-
Nonlinear secondary arc model use for evaluation of single pole auto-reclosing effectiveness
PublikacjaPurpose – The purpose of this paper is to discuss two evaluation methods of single pole autoreclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc implementation is presented. Design/methodology/approach – A computer simulation studies were...
-
Obliczanie rozpływu prądów zwarciowych w przewodach odgromowych linii WN
PublikacjaW referacie przedstawiono metodę oraz jej implementację w postaci programu komputerowego, które umożliwiają obliczenie rozpływu prądów zwarciowych w linkach odgromowych linii wysokiego napięcia. Algorytm umożliwia obliczenia dla linii dwustronne zasilanej oraz linii w układzie gwiazdowym (z odczepem). Opracowany program umożliwia weryfikację doboru przewodów odgromowych z punktu widzenia wytrzymałości zwarciowej cieplnej.
-
Obliczenia rozpływu prądów zwarciowych w przewodach odgromowych linii WN
PublikacjaW artykule przedstawiono metodę oraz jej implementację w postaci programu komputerowego, które umożliwiają obliczenie rozpływu prądów zwarciowych w linkach odgromowych linii wysokiego napięcia. Algorytm umożliwia obliczenia dla linii dwustronnie zasilanej oraz linii w układzie gwiazdowym (z odczepem). Opracowany program umożliwia weryfikację doboru przewodów odgromowych z punktu widzenia wytrzymałości zwarciowej cieplnej.
-
Problematyka doboru zabezpieczeń dławików kompensacyjnych pracujących w sieciach najwyższych napięć
PublikacjaW artykule przedstawiono trudności, jakie napotyka się podczas projektowania systemu zabezpieczeń dla dławików przyłączanych bezpośrednio do sieci najwyższych napięć (NN). Bazując na przykładzie budowanej aktualnie stacji 400 kV Ełk Bis, pokazano, że możliwości zabezpieczenia dławika, oparte na układach EAZ wykorzystujących pomiary sygnałów elektrycznych z przekładników prądowych i napięciowych, mają swoje ograniczenia i w pewnych...
-
Problematyka kompensacji mocy biernej linii elektroenergetycznych wysokiego napięcia
PublikacjaW artykule przedstawiono rozważania dotyczące doboru dławików kompensacyjnych dla linii elektroenergetycznej dwutorowej wysokiego napięcia 400 kV, na przykładzie nowo budowanej linii Ełk Bis – Alytus. W analizach uwzględniono różne stany pracy układu. Zamieszczone wyniki dotyczą poziomów napięć w stanach ustalonych, podczas procesów łączeniowych oraz zwarć.
-
Projektowanie i efektywność stabilizatora systemowego minimalizującego normę Hinf.
PublikacjaArtykuł opisuje możliwości syntezy krzepkiego stabilizatora systemowego minimalizującego normę Hinf, którego właściwości dynamiczne kształtowane są przez wybór odpowiedniej funkcji wagowej. Rozważana jest efektywność metody w procesie projektowania stabilizatora systemowego.
-
Secondary arc modelling for single pole reclosing analyses
PublikacjaThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage calculation results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc model implementation is presented. The paper presents the study results for the three types of EHV transmission...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublikacjaThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Wybrane problemy doboru zabezpieczeń dławików kompensacyjnych pracujących w sieciach najwyższych napięć
PublikacjaW referacie przedstawiono trudności jakie napotyka się podczas projektowania systemu zabezpieczeń dla dławików przyłączanych bezpośrednio do sieci najwyższych napięć (NN). Referat, bazując na przykładzie budowanej aktualnie stacji 400 kV Ełk Bis, pokazuje, że możliwości zabezpieczenia dławika, oparte na układach EAZ wykorzystujących pomiary sygnałów elektrycznych z przekładników prądowych i napięciowych mają swoje ograniczenia...
-
Wybrane problemy kompensacji mocy biernej linii elektroenergetycznej wysokiego napięcia
PublikacjaW artykule przedstawiono rozważania dotyczące doboru dławików kompensacyjnych dla linii elektroenergetycznej dwutorowej wysokiego napięcia 400 kV, na przykładzie nowobudowanej linii Ełk Bis-Alytus . W analizach uwzględniono różne stany pracy układu. Zamieszczone wyniki dotyczą poziomów napięć w stanach ustalonych, podczas procesów łączeniowych oraz zwarć.
Rok 2014
-
Badanie działania sterownika telemechaniki z funkcją sygnalizatora zwarć w wykorzystaniem modelu referencyjnego sieci SN
PublikacjaPrzedmiotem opracowania jest analiza działania sterownika telemechaniki STGP-3 z funkcją sygnalizatora zwarć opracowanego przez Instytut Energetyki Oddział Gdańsk. Badania sterownika przeprowadzono w laboratorium Elektroenergetycznej Automatyki Zabezpieczeniowej Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublikacjaThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Detection of high frequency current components by residual current devices
PublikacjaThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Elektroenergetyczna automatyka zabezpieczeniowa farm wiatrowych
PublikacjaKsiążka prezentuje zagadnienia związane z elektroenergetyczną automatyką zabezpieczeniową farm wiatrowych. Przedstawiono zasady doboru zabezpieczeń sieci farmy wiatrowej (w tym przekładników zabezpieczeniowych) oraz elementów systemu elektroenergetycznego przylegających do farmy wiatrowej. Rozważania powyższe poparto przykładem doboru zabezpieczeń, nastaw zabezpieczeń, przekładników prądowych i napięciowych zabezpieczeniowych dla...
-
Estimation of Selected Synchronous Generator Parameters Based on the Gradient Method
PublikacjaThe authors present a method for the estimation of synchronous generator model parameters using a gradient algorithm. The paper shows an example of model parameter estimation for a turbogenerator and hydrogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test.
-
Evaluation Of Single Pole Auto-Reclosing Effectiveness With Nonlinear Secondary Arc Model
PublikacjaThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a non-linear secondary arc implementation is presented. The authors indicate, that precise representation of secondary electric arc leads to more...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublikacjaThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Proposition of the steam turbine governor structure modification
PublikacjaThere is considered the steam turbine governor operation during defense and restoration of the power system. It points out weaknesses of currently used governor structures. The new controller is proposed, that takes advantages of those curently used. The new controller allows for more effective control of the turbine in emergency situations, at frequencies much different from the nominal value.
-
Uzupełnienie klasycznego modelu matematycznego generatora synchronicznego
PublikacjaW artykule przedstawiono wyprowadzenie zależności matematycznych prowadzących do uzupełnienia tzw. klasycznego modelu matematycznego generatora synchronicznego typu generator – sieć sztywna, o możliwość obliczania transmitancji zakłóceniowej. Model ten zweryfikowano przez porównanie z modelem generator-sieć sztywna z modelem generatora 7-go rzędu.
-
Warunek zwarciowy SkQ/Sn>=20 ograniczeniem rozwoju OZE
PublikacjaW referacie omówiono zagadnienia związane z warunkiem zwarciowym, czyli ilorazem mocy zwarciowej w rozpatrywanym miejscu przyłączenia do sieci elektroenergetycznej źródła energii i mocy znamionowej tego źródła. Wskazano jego pochodzenie oraz przedyskutowano zasadność jego stosowania w analizach przyłączeniowych.
-
Wpływ odnawialnych źródeł generacji energii na bezpieczeństwo pracy krajowego systemu elektroenergetycznego
PublikacjaW referacie omówiono ogólne problemy związane z rozwojem systemów elektroenergetycznych, w tym związane z tzw. źródłami energii odnawialnej (OZE). Na tym tle przedstawiono zagadnienia związane z bezpieczeństwem energetycznym, wpływem OZE na bezpieczeństwo i dalej zagadnienia związane z kierunkami rozwoju systemów elektroenergetycznych.
-
Zastosowanie gramianów w automatyce APKO
PublikacjaPrzedstawiono zastosowanie gramianów do oceny zapasu stabilności systemu elektroenergetycznego. Zaproponowano układ regulacji turbiny w postaci Automatyki Przeciw-Kołysaniowo Odciążającej (APKO) do ochrony turbozespołu wytwórczego przed utratą stabilności.
Rok 2013
-
Estymacja wybranych parametrów modelu generatora synchronicznego z wykorzystaniem metody gradientowej rozmytej – referat konferencyjny
PublikacjaReferat prezentuje metodę estymacji parametrów modelu generatora synchronicznego z wykorzystaniem algorytmu gradientowego. Przedstawiono przykład estymacji parametrów modelu hydrogeneratora w oparciu o przebiegi napięcia generatora podczas dwóch testów: zrzutu mocy czynnej i zrzutu mocy biernej. Prezentowane analizy zostały wykonane w autorskim programie wykorzystującym środowisko modelowania PowerFactory firmy DIgSILENT.
-
Interior Point Method Evaluation for Reactive Power Flow Optimization in the Power System
PublikacjaThe paper verifies the performance of an interior point method in reactive power flow optimization in the power system. The study was conducted on a 28 node CIGRE system, using the interior point method optimization procedures implemented in Power Factory software.
-
Koncepcja przyłączenia elektrowni fotowoltaicznej na terenie działki nr 43 obręb 2 Nowy Staw do istniejącej sieci
PublikacjaW Pracy przedstawiono wstępną koncepcję przyłączenia elektrowni fotowoltaicznej do sieci średniego napięcia na terenie gminy Nowy Staw.
-
Ocena możliwości wykorzystania metody punktu wewnętrznego do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym – referat konferencyjny.
PublikacjaW referacie poddano weryfikacji metodę punktu wewnętrznego pod kątem jej wykorzystania do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym. Rozważania przeprowadzono na 28 węzłowym systemie CIGRE, z wykorzystaniem zaimplementowanej metody punktu wewnętrznego w programie PowerFactory firmy DIgSILENT.
-
Optymalizacja poziomów napięć i rozpływów mocy biernej w systemie elektroenergetycznym z wykorzystaniem logiki rozmytej – referat konferencyjny
PublikacjaReferat prezentuje zagadnienia związane ze sterowaniem poziomami napięć w systemie elektroenergetycznym. Rozważana jest autorska metody optymalizacji rozpływu mocy biernej, prowadząca do poprawy warunków napięciowych w systemie elektroenergetycznym i ograniczenia strat mocy czynnej. Opracowana metoda optymalizacyjna bazuje na procedurze opartej o logikę rozmytą, wspomaganej algorytmem gradientowym. Metoda została zaimplementowana...
-
Start-up of a power unit of a thermal power plant auxiliary systems with supply from a hydropower plant
PublikacjaThis article discusses the issues related to a power unit of a thermal power plant start-up with the use of a hydropower plant. Hydropower plant can supply and will enable start-up of auxiliary equipment in a power unit of a thermal power plant. Due to high capacity of auxiliary drives, start-up of auxiliaries in a thermal power plant after blackout (and boiler shutdown) is not possible from emergency energy sources in the power...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublikacjaThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
VSC converters control for offshore wind farms HVDC grid connection
PublikacjaThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
Rok 2012
-
A Paradigm for HV, MV, LV Distribution Grid Development Planning
PublikacjaIn the literature, including that relating to businesses in the energy (and power) sector, the concept of these organizations’ operating paradigm may be found. The paper discusses the concept of the paradigm, with a focus on the power grid development planning paradigm. Against this background, issues related to energy security and power systems development trends and problems are presented. A new paradigm is proposed for distribution...
-
Optymalizacja rozpływów mocy biernej w systemie elektroenergetycznym
PublikacjaReferat prezentuje zagadnienia związane ze sterowaniem poziomami napięć w systemie elektroenergetycznym. Rozważane są dwie metody optymalizacji rozpływu mocy biernej, prowadzące do poprawy warunków napięciowych w systemie elektroenergetycznym i ograniczenia strat mocy czynnej. Pierwsza z metod optymalizacyjnych poddanych weryfikacji została zaimplementowana w programie PLANS, a bazuje na autorskiej procedurze opartej o logikę rozmytą,...
-
Propozycja modyfikacji struktury regulatorów turbin parowych
PublikacjaReferat podejmuje tematykę wpływu struktury regulatora turbiny na proces obrony i odbudowy systemu elektroenergetycznego. Wskazując niedoskonałości obecnie stosowanych regulatorów zaproponowano autorską strukturę regulatora turbiny parowej. Nowy regulator wykorzystuje zalety stosowanych obecnie regulatorów mocy z korektą od częstotliwości, pozwalając jednocześnie na efektywniejsze sterowanie turbinami w stanach awaryjnych, przy...
-
Steam turbines governors in power system restoration process
PublikacjaThe paper discusses problems related to electric power system restoration process. The turbine controller operating mode influence in small subsystem is analyzed. There are considered abilities, advantages and drawbacks of the controller's two operating modes: power control and speed (frequen-cy) control, to rebuild electric power system from a single generating unit to a few parallel running generators.
-
Weryfikacja działania blokad przeciwkołysaniowych na przykładzie zabezpieczeń firmy Siemens
PublikacjaReferat podejmuje tematykę działania zabezpieczeń impedancyjnych w czasie trwania synchronicznych i asynchronicznych kołysań mocy. W referacie analizowano działanie zabezpieczeń impedancyjnych generatora synchronicznego oraz linii blokowej. Wskazano na niebezpieczeństwo błędnego działania zabezpieczeń przy obecnie stosowanych sposobach ich nastawiania.
-
Weryfikacja nastawień zabezpieczeń od utraty wzbudzenia na przykładzie elektrociepłowni przemysłowej
PublikacjaW artykule przedstawiono rozważania dotyczące działania zabezpieczeń reaktancyjnych od utraty wzbudzenia generatorów synchronicznych, pracujących w elektrociepłowni przemysłowej. Pokazano możliwości niewłaściwego działania zabezpieczenia od utraty wzbudzenia, wskazując że dobór nastawień powinien każdorazowo wykorzystywać badania modelowe. Przyjmowanie nastawień typowych zgodnych z wiedzą inżynierską może być przyczyną niewłaściwego...
-
Zabezpieczenia elektroenergetyczne bloku w początkowym okresie odbudowy systemu po blackoucie
PublikacjaOmówiono etapy przechodzenia bloku elektroenergetycznego z pracy na potrzeby własne do pracy na sieć wydzieloną w procesie odbudowy systemu. Przedstawiono wymagane zabezpieczenia, które powinny chronić poszczególne elementy systemu elektroenergtycznego w poszczególnych etapach tego procesu. Przedstawiono wymagania dotyczące charakterystyk zabezpeiczenia reagującego na utratę synchronizmu wzbudzonego generatora w warunkach pracy...
-
Zabezpieczenia elektroenergetyczne bloku w początkowym okresie odbudowy systemu po blekaucie
PublikacjaOmówiono etapy przechodzenia bloku elektroenergetycznego z pracy na potrzeby własne do pracy na sieć wydzieloną w procesie odbudowy systemu. Przedstawiono wymagane zabezpieczenia, które powinny chronić poszczególne elementy systemu elektroenergtycznego w poszczególnych etapach tego procesu. Przedstawiono wymagania dotyczące charakterystyk zabezpeiczenia reagującego na utratę synchronizmu wzbudzonego generatora w warunkach pracy...
Rok 2011
-
Application capabilities of the maximum distributed generation estimate methodology
PublikacjaThe paper presents application capabilities of the maximum distributed generation estimate methodology. This subject is an example of solutions to the problem that today face the transmission system operator and distribution system operators, which is related to the high saturation with wind power generation predicted for the near future.
-
Możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej
PublikacjaW artykule przedstawiono możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej. Temat ten jest jednym z przykładowych rozwiązań problemu, który stoi dzisiaj przed operatorem systemu przesyłowego oraz przed operatorami systemów dystrybucyjnych, a związany jest z prognozowanym dużym nasyceniem energetyką wiatrową w najbliższych latach.
-
Możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej
PublikacjaW referacie przedstawiono możliwości aplikacyjne metodyki szacowania maksymalnej generacji rozproszonej. Temat ten jest jednym z przykładowych rozwiązań problemu, który stoi dzisiaj przed operatorami systemów dystrybucyjnych, a związany jest z prognozowanym dużym nasyceniem energetyką wiatrową w najbliższych latach.
-
The impact of wind farms with fixed speed induction generators on grid damping in Northern Ireland
Publikacja -
Wykorzystanie rejestracji przebiegów szybkozmiennych do weryfikacji modeli dynamicznych KSE
PublikacjaW referacie przedstawiono koncepcję narzędzia pozwalającego na weryfikowanie parametrów modeli dynamicznych elementów KSE. Narzędzie wykorzystuje program obliczeniowy PSLF, stosowany powszechnie przez operatora systemu przesyłowego. Nowatorstwo polega na wykorzystaniu dodatkowej aplikacji (programu w systemie MS Windows), która steruje pracą programu obliczeniowego. Powstaje w ten sposób tandem wygodnego interfejsu użytkownika...
wyświetlono 3168 razy