Catalog Publications
-
Analysis of odor interactions in ternary gas mixtures using electronic nose
PublicationIn recent years there has been a noticeable increase in interest in the use of electronic noses in analytical chemistry. These devices perform a holistic analysis of the gas mixtures composition, without the separation and identification of its individual components. For this reason e-noses are increasingly replacing the conventional olfactometers, due to the significantly shorter analysis time and possible automation. In the work...
-
Direct measurements of odorous volatile organic compounds present in biosolids cakes by Proton Transfer Reaction – Mass Spectrometry Technique
PublicationThis paper show the results of investigation of concentration of odorous chemical compounds emitted upon ageing of anaerobically stabilised biosolids that could contribute to the overall odour character of nuisance emissions. Biosolids samples from wastewater treatment plant were collected in spring time. Concentrations of volatile organic compounds using a US EPA flux hood and Proton Transfer Reaction-Time of Flight-Mass Spectrometry...
-
THE USE OF ULTRAFAST GAS CHROMATOGRAPHY FOR CLASSIFICATION OF PLUM SPIRITS = SPOSÓB WYKORZYSTANIA ULTRASZYBKIEJ CHROMATOGRAFII GAZOWEJ DO KLASYFIKACJI OKOWIT ŚLIWKOWYCH
PublicationStan środowiska ma znaczny wpływ na jakość upraw. W konsekwencji występowanie zanieczyszczeń w powietrzu ma istotny wpływ na jakość żywności. W skutek złego stanu powietrza zewnętrznego i wewnętrznego zmieniają się m.in. walory sensoryczne i zdrowotne niektórych produktów spożywczych. Z tego powodu należy nieustannie monitorować stan środowiska za pomocą m.in. nowoczesnej aparatury analitycznej jakim jest elektroniczny nos. W...
-
POTENTIAL APPLICATIONS OF ELECTRONIC NOSE BASED ON ULTRA FAST GAS CHROMATOGRAPHY TO DISTINGUISH ALCOHOLIC BEVERAGES MADE OF GRAIN = POTENCJALNE MOŻLIWOŚCI ZASTOSOWANIA ELEKTRONICZNEGO NOSA OPARTEGO NA ULTRA SZYBKIEJ CHROMATOGRAFII GAZOWEJ DO ODRÓŻNIANIA NAPOJÓW SPIRYTUSOWYCH POCHODZENIA ZBOŻOWEGO
PublicationStan środowiska a zwłaszcza powietrza ma wpływ na wiele aspektów życia, m in. na jakość produktów spożywczych. Z tego względu niezwykle ważne jest monitorowanie stanu środowiska, które odbywa się za pomocą wielu technik analitycznych. Jedną z nich jest elektroniczny nos. Pierwotnie elektroniczny nos był wykorzystywany tylko do badania uciążliwości zapachowej powietrza. Obecnie technika ta wykorzystywana jest również do monitorowania...
-
ODOUR IMPACT OF MUNICIPAL LANDFILL MONITORED WITH ULTRA-FAST GAS CHROMATOGRAPHY = ODDZIAŁYWANIE ZAPACHOWE SKŁADOWISKA ODPADÓW KOMUNALNYCH MONITOROWANE ZA POMOCĄ ULTRA SZYBKIEJ CHROMATOGRAFII GAZOWEJ
PublicationPrzedstawiono wyniki badań klasyfikacji próbek powietrza atmosferycznego pobranych wokół miejskiego składowiska odpadów komunalnych w okresie zimowym i letnim pod kątem uciążliwości zapachowej. Badania przeprowadzono przy pomocy komercyjnego elektronicznego nosa typu Fast/Flash GC - HERACLES II. Klasyfikację próbek powietrza atmosferycznego pobranych z różnych kierunków względem wysypiska śmieci przeprowadzano przy użyciu dyskryminacyjnej...
-
Urządzenie do wytwarzania gazowych mieszanin wzorcowych z wykorzystaniem procesu barbotażu oraz permeacji
PublicationReference gas mixtures are classified to reference materials and are mainly used for quality monitoring and identification of impurities in atmospheric air. They can be also used for calibration of measuring devices. Nowadays, there is a need to develop a new techniques for the preparation of reference gas mixtures [1, 2]. In this paper the design and the operating principles of instrument based on the use of barbotage and permeation...
-
Monitoring of odour nuisance on the adjacent areas to the landfill using fast GC and sensory analysis
PublicationThe paper shows the results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during August and September period have been presented. The studies was conducted by the use of Fast GC HERACLES II from AlphaMOS company and sensory analysis. About 86% of the atmospheric air samples ollected were classified correctly using PCA and LDA. Based on a classification of the atmospheric...
-
Bezpośrednia analiza próbek z wykorzystaniem techniki spektrometrii mas. Cz. I. Rozwiązania metodyczne w zakresie spektrometrii mas umożliwiające bezpośrednią analizę próbek
PublicationTechnika spektrometrii mas stanowi jedno z najważniejszych narzędzi analitycznych, wykorzystywanych do identyfikacji, określania struktury chemicznej oraz oznaczania stężeń wielu związków chemicznych. Aby zidentyfikować obecne w próbkach rzeczywistych anality, konieczne jest jednak z reguły ich wstępne rozdzielenie, toteż spektrometry mas pełnią najczęściej rolę detektora np. w przypadku technik łączonych, gdy na etapie rozdzielania...
-
Determination of benzo(a)pyrene content in PM10 using regression methods
PublicationThe paper presents an attempt of application of multidimensional linear regression to estimation of an empirical model describing the factors influencing on B(a)P content in suspended dust PM10 in Olsztyn and Elbląg city regions between 2010 and 2013. During this period annual average concentration of B(a)P in PM10 exceeded the admissible level 1.5-3 times. Conducted investigations confirm that the reasons of B(a)P concentration...
-
Substancje złowonne powstające w oczyszczalniach ścieków i metody oceny ich uciążliwości zapachowej
PublicationW artykule przedstawiono informacje o źródłach emisji substancji złowonnych z oczyszczalni ścieków do otoczenia. Ponadto opisano jakie substancje odpowiadają za występowanie uciążliwości zapachowej i które z nich mogą stanowić potencjalny marker emisji zapachowej. Scharakteryzowano techniki pomiaru stężeń substancji złowonnych zarówno sensoryczne jak i instrumentalne jednocześnie określając ich użyteczność praktyczną. W pracy przedstawiono...
-
POWIĄZANIE INTENSYWNOŚCI ZAPACHOWEJ Z SYGNAŁAMI CZUJNIKÓW ELEKTRONICZNEGO NOSA
PublicationW ostatnich latach obserwuje się znaczny wzrost zainteresowania tematyką wykorzystania sztucznych zmysłów w analityce chemicznej. Szczególną pozycję zajmuje urządzenie, mające naśladować zmysł węchu - elektroniczny nos. Jest to instrument umożliwiający holistyczną analizę składu mieszaniny gazowej, bez rozdzielania i identyfikacji jej poszczególnych składników. Głównym zadaniem, stawianym tym urządzeniom, jest automatyczne rozróżnianie...
-
WYKORZYSTANIE NOWOCZESNYCH TECHNIK INTSTRUMENTALNYCH I SENSORYCZNYCH DO OCENY JAKOŚCI POWIETRZA ATMOSFERYCZNEGO NA TERANACH PRZYLEGŁYCH DO RAFINERII GRUPY LOTOS S.A. W GDAŃSKU
PublicationDynamiczne postępujący rozwój gospodarczy i ekonomiczny wielu krajów przyczynia się do wzrostu emisji zanieczyszczeń do powietrza atmosferycznego. Większość z nich wpływa negatywnie na zdrowie i życie człowieka, oraz przyczynia się do pogorszenia stanu środowiska naturalnego. Na szczególną uwagę zasługują gazy złowonne określane także mianem odorów. Zdecydowaną większość emiterów, których funkcjonowanie wiąże się z uwalnianiem...
-
WYKORZYSTANIE TECHNIK OLFAKTOMETRII TERENOWEJ I GC×GC-TOFMS DO OCENY UCIĄŻLIWOŚCI ZAPACHOWEJ POWIETRZA ATMOSFERYCZNEGO NA OBSZARACH PRZYLEGŁYCH DO SKŁADOWISKA ODPADOW KOMUNALNYCH W GDAŃSKU SZADÓŁKACH
PublicationW artykule przedstawiono wyniki badań przeprowadzonych na obszarach sąsiadujących ze składowiskiem odpadów komunalnych w Gdańsku-Szadółkach. Do oceny uciążliwości zapachowej powietrza atmosferycznego wykorzystano technikę olfaktometrii terenowej. Narzędziami, których wykorzystanie umożliwia badanie właściwości zapachowych odorantów występujących w powietrzu atmosferycznym in-situ są olfaktometry terenowe, których zastosowanie umożliwia...
-
Bezpośrednia analiza próbek z wykorzystaniem techniki spektrometrii mas. Cz. II. Technika PTR – MS – ciekawe rozwiązanie metodyczne w zakresie spektrometrii mas
PublicationTechnika spektrometrii mas stanowi niezwykle istotne narzędzie badawcze, umożliwiające uzyskanie wielu cennych informacji, dotyczących składu chemicznego wielu próbek rzeczywistych pochodzenia biologicznego, farmaceutycznego i spożywczego. Spektrometr mas zazwyczaj pełni role detektora w przypadku stosowania połączenia z urządzeniami chromatograficznymi (GC, LC). Dzięki zastosowaniu pewnych modyfikacji aparaturowych i metodycznych,...
-
Ekspertyza dotycząca bezzasadności zarzutów odnośnie parametrów metrologicznych analizatorów pyłu PM2,5 postawionych firmom EAS Envimet Polska Sp. z o.o. i EAS Envimet Analytical Systems GmbH przez spółkę MLU Sp. z o.o. z siedzibą w Katowicach w postępowaniu odwoławczym o sygn. akt: KIO/UZP 435/09
PublicationW ekspertyzie sporządzonej dla EAS Envimet Polska sp. z o.o. z siedzibą w Wieliczce wykazano bezzasadność zarzutów zgłoszonych przez Spółkę MLU w Katowicach w odniesieniu do urządzenia BAM1020 w postępowaniu odwoławczym toczącym się przed Prezesem Urzędu Zamówień Publicznych w związku z zaskarżeniem rozstrzygnięcia przetargu o zamówienie publiczne nr DM/5211-06-02/09/ABA na zakup automatycznego miernika pyłu zawieszonego PM2,5...
-
Testy równoważności metod pomiarowych dla pyłu zawieszonego pm10
PublicationCelem prowadzonych badań było wykazanie równoważności metody wagowej oznaczania pyłu PM10, spełniającej wymogi referencyjności, z metodami oznaczania "on-site" dla losowo dobranych par danych (4 symulacje). We wszystkich przypadkach równoważność określona została za pomocą trzech odrębnych analiz: zgodnie z procedurą opisaną w Normie Europejskiej EN 12341:1998 oraz z wykorzystaniem analiz regresji ortogonalnej i liniowej, w celu...
-
Szacowanie zawartości benzo(a)pirenu w pyle zawieszonym pm10 przy pomocy wielowymiarowej regresji liniowej
PublicationW pracy przedstawiono próbę oszacowania przy pomocy wielowymiarowej regresji liniowej modelu empirycznego opisującego czynniki wpływające na zawartość B(a)P w pyle zawieszonym PM10 w jednej z dzielnic aglomeracji trójmiejskiej, gdzie głównym źródłem występowania B(a)P była niska emisja, spowodowana spalaniem paliw kopalnianych. Analizie poddano wzajemne zależności: stężenia pyłu PM10 w powietrzu, temperaturę powietrza, prędkość...
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublicationThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
-
Prototypowy czujnik do oznaczania lotnych związków opganicznych w powietrzu
PublicationW pracy zaprezentowano prototypowy elektrochemiczny czujnik zbudowany na bazie cieczy jonowej do oznaczania związków z grupy lotnych związków organicznych (LZO). W czujniku zostały użyte komercyjne elektrody firmy DropSens. w postaci pasków z nadrukowanymi elektrodami na ceramicznym podłożu. Jako elektrolit i środowisko reakcji redox wykorzystano następujące ciecze jonowe: dicyjanoamid 1-butylo-3-metyloimidazoliowy ([BMIM][N(CN2)]),...
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublicationThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Equivalence of on-line and reference methods for measurement of pm10 = Równoważność metod pomiarowych on-line i odniesienia stosowanych do oznaczania pm10
PublicationW badaniach nad równoważnością wyników otrzymanych za pomocą pomiaru ciągłego PM10 w stosunku do metody odniesienia stosuje się nienormatywny przewodnik unijny "Demonstration of Equivalence of Ambient Air Monitoring Methods. EC Working Group on Guidance for the Demonstration of Equivalence". W pracy omówiono sposób postępowania wg tego przewodnika. Na podstawie testu terenowego przeprowadzonego na terenie Gdańska w latach 2010-2011...
-
Electronic nose as a tool for differentiation of volatile organic compounds = Elektroniczny nos jako instrument do rozróżniania lotnych związków organicznych
PublicationW pracy porównano dwie metody analizy zapachów lotnych związków organicznych: klasyczną analizę opartą na percepcji ludzkiego węchu i technikę elektronicznego nosa. W przeprowadzonych badaniach za pomocą klasycznej analizy brało udział 8 ochotników w okresie 2 tygodni. Do instrumentalnej metody analizy zapachu wykorzystano zaprojektowany przez autorów prototypowy 6-cio czujnikowy elektroniczny nos. Przeprowadzone badania z wykorzystaniem...
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublicationThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Application of ionic liquids in electronic nose instruments
PublicationAmong many applications in different fields of science and technology the ionic liquids (ILs) are also utilised in chemical sensors yielding improvement of their operation parameters (Buzzeo, 2004; Wei and Ivaska, 2008; Silvester, 2011; Gebicki et al., 2013). Some of these chemical sensors are the components of the devices, which resemble human sense of smell as far as their operation is concerned. These devices are named electronic...
-
Monitoring of odour nuisance in the Tricity Agglomeration
PublicationThe paper describes a principle of operation of odour nuisance monitoring network, which is being designed in the Tricity Agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The...
-
Elektrochemiczny czujnik na bazie cieczy jonowej do oznaczania par benzaldehydu
PublicationW pracy przedstawiono prototypowy, laboratoryjny, elektrochemiczny czujnik do oznaczania par benzaldehydu w argonie. Cieczą jonową testowaną jako elektrolit i środowisko reakcji redox była: bis(trifluorometylosulfonylo)imidek 1-butylo,3-metyloimidazolinowy ([BMIM][Tf2N]). W pomiarach użyto komercyjnych elektrod firm: DropSens Co. i BVT Technologies. Walidacji poddano dwa parametry metrologiczne czujnika: granicę wykrywalności i...
-
Równoważność metod pomiarowych ciągłych i odniesienia stosowanych do oznaczania pm10
PublicationW pracy przedstawiono wyniki testu terenowego przeprowadzonego na terenie Gdańska w okresie od 01-01-2010 do 31-12-2010 i od 01-01-2011 do 31-12-2011 w celu wykazania równoważności wskazań analizatora Eberline FH 62-1 w stosunku do wagowej metody odniesienia. Przedyskutowano występowanie różnic wskazań wartości stężeń pyłu PM10 w zależności od pory roku dla obu metod pomiarowych. Przedstawiono sposób określania równoważności tych...
-
Elektrochemiczny gazowy czujnik na bazie cieczy jonowej do oznaczania benzaldehydu
PublicationW pracy przedstawiono wyniki badań dotyczące opracowania dwóch wersji prototypowego, laboratoryjnego elektrochemicznego czujnika do oznaczania par benzaldehydu. Elektrolitem w tych czujnikach była ciecz jonowa [HMIM][Tf2N] (bis(trifluorometylosulfonylo)imidek 1-heksylo,3-metyloimidazolinowy). Jeden z czujników zbudowany był wg koncepcji Clarka z membraną PDMS, drugi z użyciem komercyjnych elektrod firmy DropSens Co. W obu wersjach,...
-
Comparative field test for measurement of PM10 dust in atmospheric air using gravimetric (reference) method and b-absorption method (Eberline FH 62-1)
PublicationThe paper presents the results of a field test carried out in Gdansk region between 01-01-2010 and 31-12-2010 in order to demonstrate equivalence of the Eberline FH 62-1 sampler to the reference gravimetric method of suspended PM10 dust measurement. The differences in PM10 dust concentration provided by both methods have been discussed for different seasons of the year. A method of estimation of the correction factors/correction...
-
Identification of pollutants at the adjacent areas to the landfill site using two dimensional gas chromatography with mass spectrometry technique
PublicationMunicipal landfills are considered one of the main sources of air pollutants. In this article is presented the use of a modern analytical technique: a two dimensional gas chromatography to identify the substances in the atmospheric air near a waste processing plant located in Gdansk. In order to determine the types of substances occurring in different atmospheric conditions, the study was conducted from February to April 2016....
-
Identification of aromatic compounds in odours mixture by gas chromatography and field olfactometry techniques
PublicationThis paper shows the results of investigation on identification aromatic compounds present in odorous mixture in atmospheric air samples collected in a vicinity of the oil refinery LOTOS S.A., located in Gdansk, during March and April period have be presented. The studies were conducted by the use of comprehensive two-dimensional gas chromatograph equipped with a cryogenic modulator and coupled with a time-of-flight mass spectrometer,...
-
Comprehensive two dimensional gas chromatography coupled with mass spectrometry as tool for characterization of the main pollutants present in atmospheric air in Gdansk
PublicationNowadays, the technique that is commonly used to identify and quantify the chemical compounds in gas sample is gas chromatography. The separation resolution in gas chromatography can be improved by applying the modulation technique. In this paper present is the most important information regarding the pollutants present in atmospheric air. The areas in which the tests were carried out are one of the largest industrial zones in...
-
Electronic nose algorithm design using classical system identification for odour intensity detection
PublicationThe two elements considered crucial for constructing an efficient environmental odour intensity monitoring systems are sensors and algorithms typically addressed to as electronic nose sensor (e-nose). Due to operational complexity of biochemical sensors developed in human bodies algorithms based on computational methods of artificial intelligence are typically considered superior to classical model based approaches in development...
-
Sorbents modified by deep eutectic solvents in microextraction techniques
PublicationIn recent years, considerable attention has been directed towards the employment of green solvents, specifically deep eutectic solvents (DES), in liquid phase microextraction techniques. However, comprehensive and organized knowledge regarding the modification of sorbent surface structures with DES remains limited. Therefore, this paper reviews the application of DES in modifying and improving the properties of sorbents for microextraction...
-
Process control of air stream deodorization from vapors of VOCs using a gas sensor matrix conducted in the biotrickling filter (BTF)
PublicationThis article presents the validity, advisability and purposefulness of using a gas sensor matrix to monitor air deodorization processes carried out in a peat-perlite-polyurethane foam-packed biotrickling filter. The aim of the conducted research was to control the effectiveness of air stream purification from vapors of hydrophobic compounds, i.e., n-hexane and cyclohexane. The effectiveness of hydrophobic n-hexane and cyclohexane...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublicationThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Investigations on the removal of hydrophobic odorous volatile organic compounds by biotrickling filtration monitored with electronic nose
PublicationThe presented paper presents the results of research on the removal of selected hydrophobic volatile organic compounds (VOCs) from their mixture with air by means of a trickled-bed biofiltration. The efficiency of the removal of toluene and α-pinene, as model VOCs, in a three-section biotrickling filter is evaluated using GCFID and additionally monitored with an electronic nose. The results show that the removal of the model mixture...
-
Magnetic deep eutectic solvents as efficient media for extraction of furfural and 5-hydroxymethylfurfural from aqueous samples
PublicationThe extraction of furfural (FF) and 5-hydroxymethylfurfural (HMF) from hydrolysates is currently one of the main challenges in bio-refinery. In this work, the separation of FF and HMF from the aqueous phase was carried out using a new type of green solvents – Magnetic Deep Eutectic Solvents (MDES). A conductor-like screening model for realistic solvents (COSMO-RS) was used for the preselection of 400 MDES. MDES which exhibit the...
-
Evaluation of Linkers’ Influence on Peptide-Based Piezoelectric Biosensors’ Sensitivity to Aldehydes in the Gas Phase
PublicationRecent findings qualified aldehydes as potential biomarkers for disease diagnosis. One of the possibilities is to use electrochemical biosensors in point-of-care (PoC), but these need further development to overcome some limitations. Currently, the primary goal is to enhance their metrological parameters in terms of sensitivity and selectivity. Previous findings indicate that peptide OBPP4 (KLLFDSLTDLKKKMSEC-NH2) is a promising...
-
Comparison of different types of electronic nose instruments for evaluation of odour nuisance from landfill
PublicationThe paper presents and compares the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with six semiconductor sensors of TGS type. Classification of the air...
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublicationThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
Comparison of the Measurement Techniques Employed for Evaluation of Ambient Air Odour Quality Influenced by Operation of Industrial Sewage Treatment Plant
PublicationThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of a sewage treatment plant of the LOTOS Group S.A. petroleum plant. The investigation was performed during winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type...
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublicationThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Deep Eutectic Solvents and Their Uses for Air Purification
PublicationChemical compounds released into the air by the activities of industrial plants and emitted from many other sources, including in households (paints, waxes, cosmetics, disinfectants, plastic (PVC) flooring), may affect the environment and human health. Thus, air purification is an important issue in the context of caring for the condition of the environment. Deep eutectic solvents (DESs) as liquids with environmentally friendly...
-
Application of Electronic Nose to Ambient Air Quality Evaluation With Respect to Odour Nuisance in Vicinity of Municipal Landfills and Sewage Treatment
PublicationThis chapter contains information about application of the electronic nose type instruments to evaluation of ambient air odour quality connected with such sectors of human activity as municipal landfills or sewage treatment plants. The authors present potential sources of emission from these sectors, characterize the chemical compounds responsible for presence of unpleasant odours, describe the influence of those compounds on human...
-
Electronic Noses for Indoor Air Quality Assessment
PublicationThis chapter presents a proposal of the use of electronic noses in the monitoring of indoor air quality. The main focus is put on the detailed characteristics of today’s indoor air quality control methods, the types of pollution in the air, and the development of electronic noses for air testing. Currently, scientists seek methodological and structural solutions that would enable real-time online indoor air control. It has been...
-
Influence of Humidity on Parameters of Amperometric Sensor with Nafion Membrane
PublicationPrzedstawiono wyniki badań wpływu umiarkowanych i wysokich wilgotności powietrza na sygnał, czułość i czas odpowiedzi prototypowego czujnika ditlenku siarki ze złotą elektrodą pracującą, próżniowo napyloną na powierzchnię membrany nafionowej. Zaprezentowano także wyniki badań impedancyjnych w zakresie potencjałów, w którym mechanizm utleniania ditlenku siarki jest kontrolowany aktywacyjnie i dyfuzyjnie. Parametry odpowiadające...
-
Investigations of a new humidity sensor with polymer film
PublicationPrzedstawiono wyniki badań impedancyjnych nowego czujnika wilgotności z filmem polimerowym. Jako polimer wykorzystano chemicznie modyfikowaną polietylenoiminę.
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublicationMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...