Filters
total: 757
filtered: 168
Search results for: chest perfusion ct
-
Interferon‐free therapy as the cause of white matter tracts and cerebral perfusion recovery in patients with chronic hepatitis C
Publication -
DentalSegmentator: Robust open source deep learning-based CT and CBCT image segmentation
Publication -
Sensitivity calibration procedures in optical‐CT scanning of BANG®3 polymer gel dosimeters
Publication -
Opinion about causes of framing of Kingston chest (box cooler) damage, on PSV vessel VS4411 DF-PSV (B-855)
PublicationThe subject of analysis is a damage of welded connection of box cooler framing segments, made as separate bars 50mm thickness, connected by the welds in corners. Studies of documents delivered by Customer shows cracks on the fusion of filet welds and twisting of box cooler frame. The subject of analysis is a damage of welded connection of box cooler framing segments, made as separate bars 50mm thickness, connected by the welds...
-
Rating mathematical models for first-pass of tracer in pCT lung studies
PublicationThis paper presents a comparison of model based on the Gauss function and the most commonly used Gamma-variate model in perfusion computed tomography (pCT) lung studies. It also verifies whether used model affects value of blood volume parameter. Three mean concentration-time curves were created from actual pCT measurements: arterial input function, blood vessels in lungs and lung parenchyma. On the basis of these mean curves we...
-
Nasal endoscopy: an adjunct to patient selection for preoperative low-dose CT examination in chronic rhinosinusitis
Publication -
SU‐GG‐T‐357: Initial Evaluation of a Fast Optical CT Scanner for Gel Dosimetry
Publication -
Performance of a commercial optical CT scanner and polymer gel dosimeters for 3‐D dose verification
Publication -
Fracture evolution in concrete compressive fatigue experiments based on X-ray micro-CT images
PublicationArtykuł omawia ewolucje pękania w betonie podczas cyklicznego ściskania betonu. Przestrzenną ewolucję pękania zobrazowano stosując mikro-tomograf rentgenowski. Zdjęcia wykonano dla różnych cykli zmęczeniowych. Wyniki porównano z testami monotonicznymi. Jakościowa ewolucja objętości pękania ze wzrostem zmęczeniowego zniszczenia pokazała silnie nieliniowy kształt.
-
Ability of paramedics to perform endotracheal intubation during continuous chest compressions: a randomized cadaver study comparing Pentax AWS and Macintosh laryngoscopes
Publication -
Comparison of two infant chest compression techniques during simulated newborn cardiopulmonary resuscitation performed by a single rescuer: A randomized, crossover multicenter trial
Publication -
Primary mediastinal B-cell lymphoma – metabolic and anatomical features in 18FDG-PET/CT and response to therapy
Publication -
Characteristics of a new polymer gel for high-dose gradient dosimetry using a micro optical CT scanner
Publication -
Investigations on fracture in reinforced concrete beams in 3-point bending using continuous micro-CT scanning
PublicationThis study explores a fracture process in rectangular reinforced concrete (RC) beams subjected to quasi-static three-point bending. RC beams were short and long with included longitudinal reinforcement in the form of a steel or basalt bar. The ratio of the shear span to the effective depth was 1.5 and 0.75. The focus was on the load–deflection diagram and crack formation. Three-dimensional (3D) analyses of the size and distribution...
-
Value of Perfusion-Weighted MR Imaging in the Assessment of Early Cerebral Alterations in Neurologically Asymptomatic HIV-1-Positive and HCV-Positive Patients
Publication -
Current understanding of the effects of inspiratory resistance on the interactions between systemic blood pressure, cerebral perfusion, intracranial pressure, and cerebrospinal fluid dynamics
Publication -
Microemulsion-Mediated Synthesis and Properties of Uniform Ln:CaWO4(Ln = Eu, Dy) Nanophosphors with Multicolor Luminescence for Optical and CT Imaging
Publication -
KOMPLEKSOWY PROJEKT ZAMOCOWANIA FUNDAMENTU RISERA EKSPORTU ROPY ORAZ FUNDAMENTÓW RUR CT NA PLATFORMIE LOTOS PETROBALTIC
PublicationCelem pracy było wykonanie dokumentacji projektowo‐wykonawczej i obliczeń konstrukcji stalowych fundamentowania rurociągów wiszących zatłaczania oraz eksportu ropy montowanych na pontonie platformy „Lotos Petrobaltic”.
-
Modelling of concrete facture at aggregate level using DEM based on x-ray mu CT images of internal structure
PublicationW artykule pokazano wyniki dyskretne DEM dla pękania betonu poddanego zginaniu. Beton został symulowany jako ośrodek 4-fazowy. Mikrostrukturę betonu określono na podstawie zdjęć uzyskanych mikro-tomografem. Szczególną uwagę zwrócono na zjawiska mikrostrukturalne podczas zarysowania na poziomie kruszywa.
-
MODELLING OF CONCRETE FRACTURE AT AGGREGATE LEVEL USING DEM BASED ON X-RAY mu CT IMAGES OF INTERNAL STRUCTURE
PublicationThe paper describes two-dimensional meso-scale numerical results of fracture in notched concrete beams under quasi-static three-point bending. Concrete was modelled as a random heterogeneous 4-phase material composed of aggregate particles, cement matrix, interfacial transitional zones (ITZs) and air voids. As a numerical approach, the discrete element method (DEM) was used. The concrete micro-structure in calculations was directly...
-
A three-dimensional meso-scale approach to concrete fracture based on combined DEM with x-ray micro-CT images
PublicationArtykuł omawia wyniki numeryczne uzyskane stosując 3-wymiarowy mezoskopowy model do opisu pękania w betonie na poziomie kruszywa w belce z nacięciem podczas zginania. Do obliczeń użyto metodę elementów dyskretnych. Beton został opisany jako materiał 4-fazowy złożony z kruszywa, zaprawy, makro-porów i stref przejściowych miedzy kruszywem a zaprawą. Kształt i położenia kruszywa przyjęto na podstawie skanów z mikro-tomografu. Uzyskano...
-
Investigation of sinonasal anatomy via low-dose multidetector CT examination in chronic rhinosinusitis patients with higher risk for perioperative complications
Publication -
Validation of high-resolution 3D patient QA for proton PBS and IMPT using laser CT of improved polymer gel dosimeters
Publication -
SU‐FF‐T‐209: New Polymer Gel Dosimeter with High Refractive Index for Artifact‐Free Optical CT Scanning
Publication -
Emphysema affects the number and appearance of solitary pulmonary nodules identified in chest low-dose computed tomography: a study on high risk lung cancer screenees recruited in Silesian District
Publication -
Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner
Publication -
Application of EARL (ResEARch 4 Life®) protocols for [18F]FDG-PET/CT clinical and research studies. A roadmap towards exact recovery coefficient
Publication -
The Preoperative Maximum Standardized Uptake Value Measured by 18F-FDG PET/CT as an Independent Prognostic Factor of Overall Survival in Endometrial Cancer Patients
Publication -
SU-FF-T-192: Complete 3D QA for Rapid Arc Using BANG Polymer Gel and OCTOPUS-IQ Fast Laser CT Scanner
Publication -
Room temperature synthesis of water-dispersible Ln 3+ :CeF 3 (Ln = Nd, Tb) nanoparticles with different morphology as bimodal probes for fluorescence and CT imaging
Publication -
Comparing radioactive tracers 18F-FDG and 18F-FLT in the staging of diffuse large B-cell lymphoma by PET/CT examination: A single-center prospective study
Publication -
SU‐GG‐T‐208: 3‐D Dosimetric Comparison of IMRT with 2.5 Mm HD120 MLC Using Optical CT Based Polymer Gel and PRESAGE Dosimeters
Publication -
Modelowanie wybranych własności mechanicznych struktur po-rowatych przeznaczonych na trzony długoterminowych implan-tów ortopedycznych, otrzymywanych z wykorzystaniem metod micro-CT oraz SLM
PublicationArtykuł przedstawia metodologię opracowania geometrii materiału porowatego opartego na bazie stopu tytanu. W metodologii tej dąży się do uzyskania struktury porowatej jak najbardziej zbliżonej do struktury zdrowej tkanki kostnej, bazującej na rzeczywistych modelach geometrycznych uzyskanych ze zdjęć rentgenowskich z tomografii komputerowej. Rzeczywisty materiał po odpowiedniej obróbce modelu geometrycznego oraz przy zachowaniu...
-
Effect of CPAP on Blood Pressure in Patients With OSA/Hypopnea
Publication -
Theophylline Therapy for Cheyne-Stokes Respiration During Sleep in a 41-Year-Old Man With Refractory Arterial Hypertension
Publication -
Efficacy, pharmacokinetics, and safety of the biosimilar CT-P10 compared with rituximab in patients with previously untreated advanced-stage follicular lymphoma: a randomised, double-blind, parallel-group, non-inferiority phase 3 trial
Publication -
Invasive Assessment of the Myocardial Microcirculation during Beating Heart Coronary Artery Bypass Grafting
PublicationCoronary artery bypass grafting may be associated with several cardiac complications, including ischemia, acute myocardial infarction, arrhythmias, or hemodynamic instability. Accumulating evidence suggests that well-developed coronary collateral circulation may protect against adverse effects, including myocardial ischemia. Assessment of myocardial microvascular perfusion is, therefore, of great clinical interest in beating heart...
-
Quantitative fluorescent determination of DNA – Ochratoxin a interactions supported by nitrogen-vacancy rich nanodiamonds
PublicationOchratoxin A (OTA) is a hazardous contaminant of a large variety of plant and animal originated food. Herein, we report an interaction of OTA with calf thymus DNA (ct DNA) on the nanodiamond surface. We employed multispectroscopic techniques to elucidate the binding mechanism of OTA with ct DNA. The fluorescence and UV–Vis spectroscopy results show that OTA binds to ds ct DNA and forms complexes. We obtained the binding constants...
-
Classification of Covid-19 using Differential Evolution Chaotic Whale Optimization based Convolutional Neural Network
PublicationCOVID-19, also known as the Coronavirus disease-2019, is an transferrable disease that spreads rapidly, affecting countless individuals and leading to fatalities in this worldwide pandemic. The precise and swift detection of COVID-19 plays a crucial role in managing the pandemic's dissemination. Additionally, it is necessary to recognize COVID-19 quickly and accurately by investigating chest x-ray images. This paper proposed a...
-
System Loss in UWB Off-Body Communications in a Ferry Environment
PublicationIn this paper, the system loss in UWB off-body communications in a ferry environment based on measurements is presented. A mobile measurement set-up, consisting of WBAN nodes with UWB DWM1000 modules, was used. System loss was split into LOS and NLOS conditions. For the former, the smallest mean value, 24.4 dB, was obtained for the user approaching the fixed terminal, with the antenna on his chest, and the largest, 28.1 dB, for...
-
Thermal sequences database of the skin flaps in breast reconstruction and burns
PublicationThis paper presents a database of Active Dynamic Thermography (ADT) thermal sequences gathered throughout 6 year study on ADT application in skin flap blood perfusion monitoring and burn wounds diagnosis. For skin flap monitoring the database comprises of data collected during three different breast reconstruction procedures. The patients were monitored pre, intra and post surgically within 90 days period. The sequences were used...
-
Thermal sequences database of the skin flaps in breast reconstruction and burns
PublicationThis paper presents a database of Active Dynamic Thermography (ADT) thermal sequences gathered throughout 6 year study on ADT application in skin flap blood perfusion monitoring and burn wounds diagnosis. For skin flap monitoring the database comprises of data collected during three different breast reconstruction procedures. The patients were monitored pre, intra and post surgically within 90 days period. The sequences were used...
-
Proposal of New Tracer Concentration Model in Lung PCT Study Comparison with Commonly Used Gamma-variate Model
PublicationPerfusion computed tomography (pCT) is one of the methods that enable non-invasive imaging of the hemodynamics of organs and tissues. On the basis of pCT measurements, perfusion parameters such as blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) are calculated and then used for quantitative evaluation of the tissue condition. To calculate perfusion parameters it is necessary to approximate...
-
Increased inspiratory resistance alters the cardiac contribution to the dynamic relationship between blood pressure and pial artery pulsation oscillations in healthy subjects
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance will affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
[PP.17.01] INCREASED INSPIRATORY RESISTANCE AFFECTS THE CARDIAC CONTRIBUTION TO THE RELATIONSHIP BETWEEN BLOOD PRESSURE AND PIAL ARTERY PULSATION OSCILLATIONS
PublicationThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance would affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Carotid Artery Stenting and Blood–Brain Barrier Permeability in Subjects with Chronic Carotid Artery Stenosis
PublicationFailure of the blood-brain barrier (BBB) is a critical event in the development and progression of diseases such as acute ischemic stroke, chronic ischemia or small vessels disease that affect the central nervous system. It is not known whether BBB breakdown in subjects with chronic carotid artery stenosis can be restrained with postoperative recovery of cerebral perfusion. The aim of the study was to assess the short-term effect...
-
New perspective on the in vivo use of cold stress dynamic thermography in integumental reconstruction with the use of skin-muscle flaps
PublicationAmong the problems encountered by plastic surgeons is the reconstruction of defects following tumors. One of the reconstructive options is TRAM flap. Despite that anatomy is well-explored, marginal flap necrosis may develop. To minimize complications imaging examinations was designed to determine the degree of flap perfusion. One of them is the thermographic examination.
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublicationThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Performance of a new commercial high-definition 3D patient specific quality assurance system for CyberKnife robotic radiotherapy and radiosurgery
PublicationConventional two dimensional and low-definition measurement techniques for dosimetric verification of radiotherapy treatment deliveries are no longer adequate in the era of hypofractionation and extremely high dose gradients. New quality assurance (QA) tools with 3D capability and high definition are urgently needed. The purpose of this study was to evaluate the performance of one of the first such commercial systems as applied...
-
Enhancing Renal Tumor Detection: Leveraging Artificial Neural Networks in Computed Tomography Analysis
PublicationRenal cell carcinoma is one of the most common cancers in Europe, with a total incidence rate of 18.4 cases per 100 000 population. There is currently significant overdiagnosis (11% to 30.9%) at times of planned surgery based on radiological studies. The purpose of this study was to create an artificial neural network (ANN) solution based on computed tomography (CT) images as an additional tool to improve the differentiation of...