displaying 1000 best results Help
Search results for: MULTIPLE CURVE RESOLUTION
-
Using differential pressure sensor to measure nitrous oxide level in a tank
PublicationA method for measuring the level of liquid nitrous oxide oxidizer in a hybrid rocket motor oxidizer tank is proposed. Presented approach is more accurate than the most commonly used method of this measurement, which employs weighting of the whole sounding rocket or an oxidizer tank. In our solution we use a differential pressure sensor to measure the change of pressure at the bottom of an oxidizer tank in comparison to the pressure...
-
Video of LEGO Bricks on Conveyor Belt Dataset Series
PublicationThe dataset series titled Video of LEGO bricks on conveyor belt is composed of 14 datasets containing video recordings of a moving white conveyor belt. The recordings were created using a smartphone camera in Full HD resolution. The dataset allows for the preparation of data for neural network training, and building of a LEGO sorting machine that can help builders to organise their collections.
-
IT Business Standards as an Ontology Domain
PublicationThe aim of this paper is to report a selection of Semantic Web aspects pertaining to ontology development activities in the domain of the IT business standard (TOGAF 9) such as formulating competency questions, conceptualization of the domain, resolution of the source knowledge deficiency and applying common design patterns in the OWL formalization. Authors also try to determine target groups that may benefit from such ontology...
-
Melody Harmonization with Interpolated Probabilistic Models
PublicationMost melody harmonization systems use the generative hidden Markov model (HMM), which model the relation between the hidden chords and the observed melody. Relations to other variables, such as the tonality or the metric structure, are handled by training multiple HMMs or are ignored. In this paper, we propose a discriminative means of combining multiple probabilistic models of various musical variables by means of model interpolation....
-
Multipath routing for quality of service differentiation and network capacity optimization in broadband low-earth orbit systems
PublicationThis paper shows the importance of employing multiple different paths for routing in Inter-Satellite Link (ISL) networks in broadband Low-Earth Orbit (LEO) satellite systems. A theoretical analysis is presented and a routing concept is proposed to demonstrate three facts that make multipath routing especially important in broadband LEO networks: (1) differences in the propagation delays have a much greater impact on end-to-end...
-
Badanie jakości transmisji w interfejsie radiowym MC-CDMA
PublicationTechnika MC-CDMA (ang. Multi-Carrier Code Division Multiple Access) powstała z połączenia dwóch wcześniej stosowanych technik dostępu radiowego: CDMA (ang. Code Division Multiple Access) i OFDM (ang. Orthogonal Frequency-Division Multiplexing) i posiada zalety obu tych technologii. W referacie przedstawiona została budowa nadajnika i odbiornika dla tego interfejsu radiowego oraz wyniki badań symulacyjnych jakości transmisji w tym...
-
Assessment of the factors influencing on the formation of energy-oriented modes of electric power consumption by water-drainage installations of the mines
PublicationPurpose. Performing the analysis to determine energy-efficient modes and assess the characteristics of the main indicators of electric power consumption by mine water-drainage installations based on the developed research mathematical model. Methods. To achieve the purpose set, a methodology is used to develop the multiple multifactor correlation-regression modeling with respect to the modes of electric power consumption by electrical...
-
Estimation of groundwater recharge in a shallow sandy aquifer using unsaturated zone modeling and water table fluctuation method
PublicationQuantification of groundwater recharge is one of the most important issues in hydrogeology, especially in view of the ongoing changes in climate and land use. In this study, we use numerical models of 1D vertical flow in the vadose zone and the water table fluctuation (WTF) analysis to investigate local-scale recharge of a shallow sandy aquifer in the Brda outwash plain in northern Poland. We show that these two methods can be...
-
Measurement system based on USB Z-Wave controller
PublicationA wireless measurement system based on the Z-Wave standard is presented in this paper. The system is composed of a U SB Z-Stick Gen5 controller connected to a Personal Computer and a Fibaro controller FGRGBWM-441. Operation of the system is controlled by software written in C++ using OpenZWave library. Some metrological aspects of the system are evaluated: accuracy, linearity, resolution and frequency of voltage measurements.
-
Seismic response and performance prediction of steel buckling-restrained braced frames using machine-learning methods
PublicationNowadays, Buckling-Restrained Brace Frames (BRBFs) have been used as lateral force-resisting systems for low-, to mid-rise buildings. Residual Interstory Drift (RID) of BRBFs plays a key role in deciding to retrofit buildings after seismic excitation; however, existing formulas have limitations and cannot effectively help civil engineers, e.g., FEMA P-58, which is a conservative estimation method. Therefore, there is a need to...
-
Financial markets diffusion patterns. The case of Mexican investment funds
PublicationExchange traded funds (ETFs) are one of the most influential financial innovations, reshaping the investment funds market in many countries, including Mexico. Due to their similar investment objectives, ETFs are considered substitutes for mutual funds. The aim of the article is to provide an in-depth insight into the issues associated with the development of financial markets in Mexico...
-
Połączenie G3 dwóch kierunków prostych z użyciem krzywej NURBS
PublicationW artykule przedstawiono nową metodę projektowania układu geometrycznego toru kolejowego opartą na zastosowaniu krzywych NURBS (Non-Uniform Rational B-Spline) do opisu krzywizny. Punkty kontrolne krzywej NURBS wyznaczane są w procesie optymalizacji za pomocą algorytmu genetycznego. Jako kryterium optymalizacji przyjęto minimalizację oddziaływań dynamicznych występujących w układzie tor-pojazd przy spełnieniu warunków geometrycznych...
-
Analityczna weryfikacja dokładności komercyjnych programów komputerowych wspomagających projektowanie układów geometrycznych toru
PublicationW pracy podjęto próbę wyjaśnienia kwestii uzyskiwanej dokładności w projektowaniu układów geometrycznych toru z wykorzystaniem komercyjnych programów komputerowych typu CAD. Użytkownikowi najczęściej nie są znane zasady działania tych programów, w tym również wykorzystywane algorytmy obliczeniowe. Opisano w sposób ogólny funkcjonowanie dwóch wiodących programów. Przedstawiono własną, analityczną metodę projektowania układów torowych,...
-
CERVIX UTERI, Exocervix - Female, 47 - Cell image [6300730028257241]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 38 - Cell image [7020730007135911]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 37 - Cell image [4110730008004871]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 37 - Cell image [6300730028267131]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 38 - Cell image [11300630022667571]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 27 - Cell image [7040247104936671]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 48 - Cell image [6300730028254411]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 42 - Cell image [7020730007133161]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 48 - Cell image [6110730021455061]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 25 - Cell image [6300730028258791]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 43 - Cell image [6300730028265391]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
An optimal abstraction model for hardware multithreding in modern processor architectures.
PublicationPrzegląd technologii implementacji wątków sprzętowych. Propozycja abstrakcji maszyny wirtualnej SIMD (On-Demand Virtual Single Instruction Multiple Data machine) do optymalnego użycia wątków sprzętowych.
-
A CMOS Pixel With Embedded ADC, Digital CDS and Gain Correction Capability for Massively Parallel Imaging Array
PublicationIn the paper, a CMOS pixel has been proposed for imaging arrays with massively parallel image acquisition and simultaneous compensation of dark signal nonuniformity (DSNU) as well as photoresponse nonuniformity (PRNU). In our solution the pixel contains all necessary functional blocks: a photosensor and an analog-to-digital converter (ADC) with built-in correlated double sampling (CDS) integrated together. It is implemented in...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublicationThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Approximate models and parameter analysis of the flow process in transmission pipelines
Publicationthe paper deals with the problem of early leak detection in transmission pipelines. First we present the derivation of state-space equations of the flow process in the pipelines. This description is then aggregated in order to obtain a principal model. Next, the problem of process model parameterization is addressed, taking into account the maximization of a model stability margin. The location of the maximum is determined using...
-
Determination of p-y curves for offshore piles based on in-situ soil investigations
PublicationOffshore piles are subjected to complex loads with considerable lateral component. The pile-soil response to lateral loads can be described with the p-y method. For a given depth the load–deflection relationship is built to simulate the surrounding soil stiffness. This state-of-art paper presents a brief discussion of determination methods for the p-y curves using a standard approach based on the soil parameters derived from laboratory...
-
CERVIX UTERI, Exocervix - Female, 35 - Cell image [4050730010683101]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 33 - Cell image [5240730013782041]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 56 - Cell image [22206300149581]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 28 - Cell image [6280730027967741]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 33 - Cell image [7140729576841431]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 36 - Cell image [7050730000137831]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 49 - Cell image [6300730028261801]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 46 - Cell image [4100730006096741]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 40 - Cell image [4080730008354931]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 45 - Cell image [6280730027965281]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 39 - Cell image [7050730000139901]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 35 - Cell image [6280730027966381]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 41 - Cell image [6300730028268341]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 35 - Cell image [4200730008419121]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 42 - Cell image [7150729575507301]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 39 - Cell image [408073000835431]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 51 - Cell image [4080730008354351]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 37 - Cell image [4050730010686151]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 25 - Cell image [4080730008356821]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 56 - Cell image [6300730028268091]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, Exocervix - Female, 31 - Cell image [4080730008361051]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.