Filters
total: 4558
-
Catalog
displaying 1000 best results Help
Search results for: OPTICAL VELOCITY MEASUREMENT
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Using UAV Photogrammetry to Analyse Changes in the Coastal Zone Based on the Sopot Tombolo (Salient) Measurement Project
PublicationThe main factors influencing the shape of the beach, shoreline and seabed include undulation, wind and coastal currents. These phenomena cause continuous and multidimensional changes in the shape of the seabed and the Earth’s surface, and when they occur in an area of intense human activity, they should be constantly monitored. In 2018 and 2019, several measurement campaigns took place in the littoral zone in Sopot, related to...
-
Variable Temperature Spectroscopic Ellipsometry as a Tool for Insight into the Optical Order in the P3HT:PC70BM and PC70BM Layers
PublicationTwo combined ellipsometric techniques—variable angle spectroscopic ellipsometry (VASE) and variable temperature spectroscopic ellipsometry (VTSE)—were used as tools to study the surface order and dielectric properties of thin films of a poly(3-hexylthiophene-2,5-diyl) (P3HT) mixture with a fullerene derivative (6,6-phenyl-C71-butyric acid methyl ester) (PC70BM). Under the influence of annealing, a layer of the ordered PC70BM...
-
Measurement in Physical Education and Exercise Science
Journals -
A high-accuracy method of computation of x-ray waves propagation through an optical system consisting of many lenses
PublicationThe propagation of X-ray waves through an optical system consisting of many X-ray refractive lenses is considered. Two differential equations are contemplated for solving the problem for electromagnetic wave propagation: first – an equation for the electric field, second – an equation derived for a complex phase of an electric field. Both equations are solved by the use of a finite-difference method. The simulation error is estimated...
-
Optimal Placement of Phasor Measurement Unit in Power System using Meta-Heuristic Algorithms
PublicationThe phasor measurement units (PMUs) play an important and vital role in power system monitoring and controlling, since they provide the power system phasors stamped with a common real time reference through a global positioning system (GPS). Indeed, from economical point of view it is not possible to set PMUs in all system buses due to the high cost and the requirement of more complex communication...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublicationWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
Investigation of Weigh-in-Motion Measurement Accuracy on the Basis of Steering Axle Load Spectra
PublicationWeigh-in-motion systems are installed in pavements or on bridges to identify and reduce the number of overloaded vehicles and minimise their adverse eect on road infrastructure. Moreover, the collected trac data are used to obtain axle load characteristics, which are very useful in road infrastructure design. Practical application of data from weigh-in-motion has become more common recently, which calls for adequate attention to...
-
High-Power Jamming Attack Mitigation Techniques in Spectrally-Spatially Flexible Optical Networks
PublicationThis work presents efficient connection provisioning techniques mitigating high-power jamming attacks in spectrally-spatially flexible optical networks (SS-FONs) utilizing multicore fibers. High-power jamming attacks are modeled based on their impact on the lightpaths’ quality of transmission (QoT) through inter-core crosstalk. Based on a desired threshold on a lightpath’s QoT, the modulation format used, the length of the path,...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublicationThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Short-Term Blood Flow Restriction Increases Power Output and Bar Velocity During the Bench Press
Publication -
Changes of Power Output and Velocity During Successive Sets of the Bench Press With Different Duration of Eccentric Movement
Publication -
Impact of movement tempo on bar velocity and time under tension in resistance exercises with different external loads
Publication -
The Effects of Ischemia During Rest Intervals on Bar Velocity in the Bench Press Exercise With Different External Loads
Publication -
Corrigendum: Contrast Tempo of Movement and Its Effect on Power Output and Bar Velocity During Resistance Exercise
Publication -
Mechanisms positioned in a neighbourhood of their singular positions - velocity amplification in the electromagnetic damping. Part 2. Numerical Verification
PublicationPraca prezentuje zagadnienia występujące podczas elektromagnetycznego tłumienia drgań układów mechanicznych. Analizowano zachowania układu ciągłego i jego drgania. Aby przyśpieszyć tłumienie, wprowadzono specjalny dwuramienny mechanizm umieszczony pomiędzy elementem drgającym i elementem tłumiącym drgania. Mechanizm ustawiony jest w pobliżu swojego ustawienia osobliwego. Aby określić potencjalny kierunek zmian prowadzący do poprawić...
-
High-quality Experiment Dedicated to microGravity Exploration, Heat Flow and Oscillation Measurement from Gdańsk
PublicationIn this paper we propose HEDGEHOG (High-quality Experiment Dedicated to microGravity Exploration, Heat flow and Oscillation measurement from Gdańsk) REXUS experiment to investigate vibrational and heat flow phenomena during the whole (ascent, microgravity phase, descent and recovery) flight of a sounding rocket. First, a proposed system of cantilever beams is discussed to study dynamic behaviour of dummy payload. Dimensioning has...
-
Optical Emission Spectroscopy of Microwave (915 MHz) Plasma in Atmospheric Pressure Nitrogen with Addition of Ethanol Vapour
PublicationIn this paper results of optical emission spectroscopic study of microwave 915 MHz plasma in atmospheric pressure nitrogen with an addition of ethanol vapour are presented. The plasma was generated in waveguide- -supplied cylinder-type nozzleless microwave plasma source. The aim of research was to determine the rotational Trot and vibrational Tvib temperatures of CN and C2. A method called bubbling was employed to introduce alcohol (ethanol)...
-
Optical Sensor Based Gestures Inference Using Recurrent Neural Network in Mobile Conditions
PublicationIn this paper the implementation of recurrent neural network models for hand gesture recognition on edge devices was performed. The models were trained with 27 hand gestures recorded with the use of a linear optical sensor consisting of 8 photodiodes and 4 LEDs. Different models, trained off-line, were tested in terms of different network topologies (different number of neurons and layers) and different effective sampling frequency...
-
Optical emission spectroscopy of plasma generated by a waveguide-supplied microwave plasma source operated at 915MHz
PublicationIn this paper we present the results of an optical emission spectroscopic study of an atmospheric pressure microwave (915 MHz) nitrogen and nitrogen with carbon dioxide (1%) plasma at high working gas flow rate. This study was aimed at determining rotational Trot and vibrational Tvib temperatures of N+2 ions and N2, CN molecules. The plasma was generated in a waveguide-supplied cavity-resonant type microwave plasma source. All...
-
Dynamic mass measurement in checkweighers using a discrete time-variant low-pass filter
PublicationConveyor belt type checkweighers are complex mechanical systems consisting of a weighing sensor (strain gauge load cell, electrodynamically compensated load cell), packages (of different shapes, made of different materials) and a transport system (motors, gears, rollers). Disturbances generated by the vibrating parts of such a system are reflected in the signal power spectra in a form of strong spectral peaks, located usually in...
-
Optical spectroscopy and scintillation mechanisms ofCexLa1−xF3
Publication -
Optical glyphs based localization and identification system
PublicationThe paper presents a description of functioning of a platform supporting the detection of obstructive diseases in the respiratory system education process. A 16-parameter model of the respiratory system simulated in the MATLAB/Simulink environment was set in the role of the tested patient. It has been linked to the control layer, developed in the LabVIEW environment, using the SIT library (Simulation Interface Toolkit). This layer...
-
Polarization state analysis in optical coherence tomography
PublicationW artykule zaprezentowano metody analizy stanu polaryzacji światła w systemach optycznej tomografii kohererentnej. Przedstawiono różne konfiguracje systemu PS-OCT wraz z ich parametrami oraz właściwościami. Omówiono zasadę pomiaru stanu polaryzacji ściatła przy użyciu systemu PS-OCT oraz przeprowadzono dyskusję nad przydatnością metody do badania struktury materiałów silnie rozpraszających promieniowanie.
-
Fluorescence Measurements for chemical optical sensor of cobalt
PublicationW pracy zaproponowano i opisano optoelektroniczny fluorescencyjny sensor do pomiaru stężenia kobaltu w wodzie.
-
Polarization sensitive optical coherence tomography system
PublicationW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Synthesized light source for optical coherence tomography
PublicationW artykule omówiono wpływ parametrów źródła promieniowania optycznego na właściwości systemu OCT. Szczególną uwagę zwrócono na źródła syntezowane. Omówiono charakterystykę źródła zbudowanego z dwóch różnych diod SLD. Przedstawiono wyniki pomiarów, które wskazują na możliwości znacznego polepszenia czułości i rozdzielczości systemu OCT wykorzystującego takie źródło.
-
Optical Investigation of Hematocrit Level in Human Blood
PublicationW artykule przedstawiono możliwości wykorzystania metod optoelektronicznych, takich jak: spektroskopia Ramana i interferometria niskokoherencyjna do pomiaru poziomu hematokrytu ludzkiej krwi.
-
Porphyrazines with peripheral isophthaloxyalkylsulfanyl substituents and their optical properties
Publication -
Dispersion of thermo-optic coefficient of optical polymers
Publication -
Electrical and optical characterization of ITO thin films
PublicationW pracy przestawiono wyniki badań tlenku cyny domieszkowanego indem (ITO) pod kątem zastosowania jako przezroczyste elektrody. opisano metody pomiarów wybranych właściwości elektrycznych i optycznych. cienką warstwę ito, naniesioną na szklane podłoże, wykonano metodą rozpylania magnetronowego.
-
Development of optical fiber technology in Poland – 2018
Publication -
Development of optical fiber technology in Poland 2020
Publication -
Development of optical fiber technology in Poland: 2017
Publication -
<title>Applications of capillary optical fibers</title>
Publication -
Apparatus to search for optical flashes of extragalactic origin
Publication -
Development of optical fiber technology in Poland: 2014
Publication -
<title>Measurements of nonlinear optical fibers</title>
Publication -
Broadband Buses Based On Multicore Optical Fibres
Publication -
Multiclad Monomode Optical Fibres By MZD Technology
Publication -
Development of optical fiber technology in Poland 2015
Publication -
Single-Mode Quadruple-Core Optical Fibres
Publication -
Geometry design in rerfractive capillary optical fibers
Publication -
Application of optical fibres in oxidation-reduction titrations
Publication -
Optical switching technologies: problems and proposed solution
Publication -
Carbon-Coated Tellurium for Optical Data Storage
Publication -
Laser Induced Piezo-Optical Effects in Chalcogenides
Publication -
Optical and electrical properties of Pr0.8Sr0.2MnO3 thin films.
PublicationPrzedstawiono preparatykę, strukturę oraz optyczne i elektryczne właściwości cienkowarstwowego Pr0.8Sr0.2MnO3. Gęste filmy o grubości 50-70nm zostały naniesione na monokrystaliczne podłoże szafirowe metodą odwirowania prekursora polimerowego. Wyniki optycznych pomiarów zostały skorelowane z temperaturą syntezy filmów. Pokazano, że optyczne spektra zmieniają kształt wraz ze zmianą struktury filmu z amorficznej do krystalicznej....