displaying 1000 best results Help
Search results for: BLOOD
-
Clinical Medicine Insights-Blood Disorders
Journals -
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY
Journals -
MACHINE LEARNING SYSTEM FOR AUTOMATED BLOOD SMEAR ANALYSIS
PublicationIn this paper the authors propose a decision support system for automatic blood smear analysis based on microscopic images. The images are pre-processed in order to remove irrelevant elements and to enhance the most important ones - the healthy blood cells (erythrocytes) and the pathologic (echinocytes). The separated blood cells are analyzed in terms of their most important features by the eigenfaces method. The features are the...
-
The Global Burden of Disease Study 2015 and Blood Pressure
Publication -
General practitioners ignore high normal blood pressure
Publication -
GENERALISED HERSCHEL MODEL APPLIED TO BLOOD FLOW MODELLING
PublicationThis paper introduces a new rheological model of blood as a certain generalisation of the standard Herschel-Bulkley model. This model is a rheological constitutive equation and belongs to the group of the so-called generalised Newtonian fluids. Experimental data is compared with results, obtained from the new model, to demonstrate that it allows for the best agreement together with Luo-Kuang model. The new model may be easily implemented...
-
Discrete-continuous optimisation of an axial flow blood pump
PublicationThis paper presents results of discrete-continuous optimisation of an axial flow blood pump. Evolution Strategies (ES) are used as a global optimisation method in order to localise the optimal solution in relatively short time. The whole optimisation process is fully automated. This also applies to geometry modelling. Numerical simulations of the flow inside the pump is performed by means of the Reynolds-Average Navier-Stokes...
-
Educational Dataset of Handheld Doppler Blood Flow Recordings
PublicationVital signals registration plays a significant role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomena as well learn how to correctly process and interpret the data. This dataset was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly acquired signals as well as the basic methods of signal processing. This...
-
mRNA profiling for vaginal fluid and menstrual blood identification
Publication -
The analysis of selected microelements in neonatal umbilical cord blood
Publication -
Effect of CPAP on Blood Pressure in Patients With OSA/Hypopnea
Publication -
Asymmetric features of short-term blood pressure variability
Publication -
Catalase activity in blood fractions of patients with sporadic ALS
Publication -
Analysis of correlation between heart rate and blood pressure
PublicationW artykule przedstawiono analizę korelacji pomiędzy częstością akcji serca (HR) i ciśnieniem krwi (BP). Wykorzystano rzeczywiste pomiary ciśnienia skurczowego i rozkurczowego krwi zmierzonego metodą inwazyjną w tętnicy promieniowej. Ze względu na możliwe zaszumienie sygnału przeanalizowano także dane po filtracji filttrem uśredniającycm oraz wykonano analizę trendów sygnałów. Wyniki analizy zarówno danych pomiarowych jak i filtrowanych...
-
Characterisation of Escherichia coli isolates from the blood of haematological adult patients with bacteraemia: translocation from gut to blood requires the cooperation of multiple virulence factors
PublicationThe aim of the study was to investigate whether there are unique pathotypes of Escherichia coli capable of transmission from the gastrointestinal tract to the vascular bed. The study included E. coli strains isolated from clinical materials collected from 115 patients suffering from haematologic malignancies diagnosed with bacteraemia. The genotyping techniques established that 89 E. coli isolates from the blood had the same genotype...
-
RESPONSE TO ORTHOSTATIC STRESS PREDICTS OFFICE‐DAYTIME BLOOD PRESSURE DIFFERENCE, BUT NOT NOCTURNAL BLOOD PRESSURE FALL IN MILD ESSENTIAL HYPERTENSIVES: RESULTS OF THE HARVEST TRIAL
Publication -
Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
PublicationA non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublicationRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...
-
Estimation of blood pressure parameters using ex-Gaussian model
PublicationThe paper presents an example of model-based estimation of blood pressure parameters (onset, systolic and diastolic pressure) from continuous measurements. First, the signal was low pass filtered and its quality was estimated. Good quality periods were divided into beats using an electrocardiogram. Next, the beginning of each beat of the blood pressure signal was approximated basing on the function created from the sum of two independent...
-
On various modelling approaches to real-time visualisation of blood flow
PublicationThis paper reviews various modelling approaches to real-time visualisation of blood flow. These include classic, macroscale approach based on the momentum conservation equation together with a proper constitutive equation. Moreover, modern micro- and mesoscale approaches, such as molecular dynamics and dissipative particle dynamics, are discussed. Advantages and disadvantages of the discussed methods are highlighted with particular...
-
DIFFRACTION PHASE MICROSCOPY FOR OBSERVATION ON RED BLOOD CELLS FLUCTUATION
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – RBCs (Red Blood Cells). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations observation...
-
Observation on red blood cells fluctuations by diffraction phase microscopy
PublicationNowadays there is quite huge need for more and more precise and effective fast diagnostics methods in hematology diseases. One of the most important blood components are erythrocytes – Red Blood Cells (RBCs). Due to their size they are easy to observe using microscopy. It is commonly known that the shape and lifetime of RBCs allows for early disease identification. Authors present special measurement system for RBCs fluctuations...
-
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublicationThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...
-
Blood Pressure in 2016: increased impact factor and change of editors
Publication -
Blood pressure control – Slowly getting there through new strategies?
Publication -
Treatment of high blood pressure in acute stroke – The SCAST Study
Publication -
Cost‐effectiveness of blood pressure measurement and hypertension follow‐up
Publication -
Blood pressure variability: Emerging role in risk assessment and therapeutics
Publication -
The Discrete-Continuous, Global Optimisation of an Axial Flow Blood Pump
PublicationThis paper presents the results of the discrete-continuous optimisation of an axial flow blood pump. Differential evolution (DE) is used as a global optimisation method in order to localise the optimal solution in a relatively short time. The whole optimisation process is fully automated. This also applies to geometry modelling. Numerical simulations of the flow inside the pump are performed by means of the Reynolds-Average Navier-Stokes...
-
An update on medium- and low-abundant blood plasma proteome of horse
Publication -
Comparison of post-mortem ethanol level in blood and bone marrow
Publication -
Oxidative DNA Damage in Blood of CVD Patients Taking Detralex
Publication -
mRNA heptaplex protocol for distinguishing between menstrual and peripheral blood
Publication -
Ambulatory blood pressure and long-term risk for atrial fibrillation
Publication -
Take a Blood Pressure Pill or Benefit from Renal Denervation?
Publication -
Association of Office and Ambulatory Blood Pressure With Mortality and Cardiovascular Outcomes
Publication -
Effects of obstructive sleep apnea on endothelin-1 and blood pressure
Publication -
Issues in the development of new combinations of blood pressure lowering drugs
Publication -
Sex-dependent membranopathy in stored human red blood cells
Publication -
The contribution of blood-flow-induced conductivity changes to measured impedance
PublicationW pracy rozwazane sa zmiany przewodnosci zachodzace w anizotropowym osrodku i ich wplyw na mierzona rezystancje. Uzyskano to za pomoca rozszerzenia wzoru Geselowizta na przypadki anizotropowe. Wykazano, ze tylko te skladowe zmian przewodnosci wplywaja na mierzona rezystancje, dla ktorych odpowiadajacy im skladnik pola eklektrycznego byl niezerowy.Wyniki te zastosowanu do zmian rezystywnosci wywolanych zmiananmi przewodnosci plynacej...
-
Optical fiber head for monitoring of heart rate and blood oxygenation
Publication -
Computed aided system for separation and classification of the abnormal erythrocytes in human blood
PublicationThe human peripheral blood consists of cells (red cells, white cells, and platelets) suspended in plasma. In the following research the team assessed an influence of nanodiamond particles on blood elements over various periods of time. The material used in the study consisted of samples taken from ten healthy humans of various age, different blood types and both sexes. The markings were leaded by adding to the blood unmodified...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublicationNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Determination of 3,4-methylenedioxy-α-pyrrolidinobutiophenone (MDPB) in blood. A case report
PublicationSynthetic drugs, known as ‘‘legal highs’’, are still very popular on black market. The determination of their composition are required in courts of law and also to understand what potential users may be subjected to. The interest of new cathinones, e.g. MDPBP, is in view of psychoactive effects that they cause and that, in many cases, they are not controlled by law. The case outlined here concerns 19 years-old man, who was found...
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublicationIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
A review of methods of blood supply to organs of the gastrointestinal tract. State of art
PublicationThe correct assessment of blood supply is essential to eliminate possible postoperative complications. Re-anastomosis of the gastrointestinal tract after its resection must be preceded by the analysis of blood supply to the anastomosed fragments. It is important that the blood supply assessment procedure is reliable but also non-absorbing and, if possible, short. It should also be possible to repeat the procedure due to the need...
-
A SHORT REVIEW OF BLOOD FLOW MODELLING METHODS: FROM MACRO- TO MICROSCALES
PublicationThe aim of this paper it to review various scale approaches to the blood flow modelling. Blood motion may be described by three types of mathematical models according to the observed scales or resolutions, namely microscopic, mesoscopic and macroscopic descriptions. The above approaches are discussed together with their advantages and disadvantages. Several results of mesoscopic simulations are presented with particular attention...
-
Impact of surface skin temperature change on blood flow characteristics in palm
PublicationHeating a human palm during 3 minutes period causes changes in superficial skin temperature and leads to thermoregulation system response. The response time and level of flow characteristics change depend on the subject hand size and health of his vascular tree. A solution of Pennes bioheat propagation model was analyzed in order to see how much heat has to be transferred into the tissue to extort the observable reaction. The reflective...
-
A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
PublicationThe paper presents a preliminary meta-analysis of the sample correlation between pulse arrival time (PAT) and blood pressure (BP). The aim of the study was to verify sample correlation coefficient between PAT and BP using an affine model BP = a · P AT + b for systolic and diastolic blood pressure. The databases included in the search were the IEEE Xplore Digital Library, Springer Link and Google Scholar. Only papers from 2005 to...
-
The accuracy of SpaceLabs 90207 in blood pressure monitoring in patients with atrial fibrillation
Publication