Search results for: LAYOUT
-
Shaping of the turnout diverging track with variable curvature sections
PublicationThe paper presents an analytical method of shaping the turnout diverging railroad track with variable curvature segments on its length, which in an evident way distinguished it from a typical solution, made up of a single circular arc with no transition curves. Two separate causes including a linear and a nonlinear curvature one in the form of a polynomial have been examined. The obtained solutions of the problem have a universal...
-
Wideband Modeling of DC-DC Buck Converter with GaN Transistors
PublicationThe general wideband modeling method of the power converter is presented on the example of DC-DC buck converter with GaN High Electron Mobility Transistors (HEMT). The models of all basic and parasitic components are briefly described. The two methods of Printed Circuit Board (PCB) layout parameter extraction are presented. The results of simulation in Saber@Sketch simulation software and measurements are compared. Next, the model...
-
Rapid multi-objective simulation-driven design of compact microwave circuits
PublicationA methodology for rapid multi-objective design of compact microwave circuits is proposed. Our approach exploits point-by-point Pareto set identification using surrogate-based optimization techniques, auxiliary equivalent circuit models, and space mapping as the major model correction method. The proposed technique is illustrated and validated through the design of a compact rat-race coupler. A set of ten designs being trade-offs...
-
Polyarmonic model of synchronous generator for analysis of autonomous power generation systems
PublicationAbstract: This paper presents the polyharmonic modelling of synchronous generator (SG) in machine variables. The simple geometry and windings physical layout has been used for inductance calculations of a salient-pole SG. The main advantage of this model is the ease of describing an autonomous power generation system (APGS) in terms of its topology and thus providing effective analysis at the static and dynamic states, both for...
-
Jesień w Bibliotece PG
PublicationArtykuł jest podsumowaniem licznych aktywności podjętych przez Bibliotekę PG w okresie jesiennym 2023 r., ukierunkowanych na czytelnictwo, jak i wynikających z naukowo-edukacyjno-kulturalnego charakteru tej jednostki. Z zestawienia zaprezentowanych wydarzeń wyłania się obraz Biblioteki PG jako miejsca...
-
The impact of footing conditions of a vertical-axis floating-roof tank on structural shell deformation
PublicationStructural shells of fuel tanks are often subjected to geometric imperfections which may lead to exceeding the ultimate and serviceability limit states. One of the means triggering shell deformation is non-uniform settlement caused by incoherent soil conditions. Analysis carried out in the work concerns of vertical-axis, floating-roof cylindrical shell which volume is 50.000 m3, founded on a complex multi-layered soil. The sensitivity...
-
Meeting Modernisms in Gdynia
PublicationThe paper focused on the architectural heritage of the city of Gdynia, in Poland, built in 1920s and 1930s. The city was established (founded) on the seaside of the Baltic Sea as the only port of Poland – a country that regained independence after Versailles Treaty. The history of the city, built from scratch is outstanding in Europe. Modernist architecture of the city is represented by buildings built for different purposes: housing,...
-
The conducted EMI in DC-DC converters
PublicationThis book presents the phenomena of conducted electromagnetic interference (EMI) generation in DC-DC converters. The measurement and simulation are used to analyze the impact of the most important parameters on the character, level and propagation path of interference. In this book, the analysis of the interference generation and propagation is presented on the example of three basic converters. The wide banded behavior of all...
-
Energy Systems Stations, W, ET, sem.7, zimowy 22/23 (PG_00042106)
e-Learning CoursesInternal combustion engines - principle of operation and classification. Heat balance of the engine. Uniform and combined propulsion systems.The main comonents of the propulsion system. Power plant efficiency and waste heat utilization. Cooling water system, lubricating oil system, fuel oil systeml, gaseos fuel system (LNG), compressed air system, exhaust gas system. Fittings and accessories of pipeline systems in the power plant....
-
Comparative Analysis of Numerical and Experimental Studies of the Airflow Around the Sample of Urban Development
PublicationIn this paper, on the background of a short overview of the recent advances in the field of Environmental Wind Engineering (EWE), a comparison of wind tunnel experiment and numerical simulation for some cases of airflow around an urban layout have been reported. The purpose of the study is quantitative and qualitative comparison of measurements in the wind tunnel as well as numerical simulation using Ansys Fluent software. The...
-
Heat Transfer During Pool Boiling of Water, Methanol and R141b on Porous Coated Horizontal Tube Bundles
PublicationThis paper presents the results of experimental investigation of water, methanol and R141b refrigerant boiling on horizontal porous coated tube bundles supposed to represent a flooded-type evaporator. Experiments were carried out for a bundle of 19 tubes in triangular layout for two pitch-to-diameter ratio values – 1.7 and 2.0 – in atmospheric and sub-atmospheric pressure conditions. Average heat transfer coefficients – both local,...
-
Koncepcja logistycznego usprawnienia magazynu cross-dockowego przedsiębiorstwa X
PublicationCelem artykułu jest przedstawienie koncepcji logistycznego usprawnienia magazynu cross- -dockowego przedsiębiorstwa X. W oparciu o informacje dotyczące stanu faktycznego maga- zynu zostały przeprowadzone badania procesów magazynowych. Po przeprowadzeniu identyfikacji problemów zostały zaproponowane usprawnienia wybranego procesu magazynowego, które polegały na propozycji zmiany sposobu zagospodarowania magazynu. Do tego...
-
The Effects of Roadside Hazards on Road Accident Severity
PublicationThe risk of becoming involved in an accident emerges when elements of the transport system do not operate properly (man – vehicle – road – roadside). The road, its traffic layout andsafety equipment have a critical impact on road user safety. This gives infrastructural work a priority in road safety strategies and programmes. Run-off-road accidents continue to be one of the biggest problems of road safety with consequences including...
-
Integrating modelling, simulation and data management tools to create a planning support system for the improvement of air quality by urban planning solutions
PublicationThe urbanization pressure requires urban planners, designers, and policy makers to be more responsive to the challenges related to improving the quality of the urban environment and the living conditions of the inhabitants. One of the many environmental issues that need to be taken into account is urban air pollution. As the process of urban ventilation and air pollution dis-persion is significantly affected by the urban layout,...
-
Bridge Ergonomic Design: A Review
PublicationHuman error remains the most common cause of marine incidents and it is worth emphasizing that navigator’s performance is directly affected by ergonomic factors on the bridge. Studies regarding influence of bridge design and work environment on the operator are rare, thus the main purpose of this paper is to fill in this gap. Documents issued by recognized organizations, research publications and additional sources were reviewed...
-
Próba oceny efektów projektowania układów geometrycznych toru z wykorzystaniem komercyjnych programów komputerowych
PublicationW pracy podjęto kwestię dokładności uzyskiwanej w projektowaniu układów geometrycznych toru z wykorzystaniem komercyjnych programów komputerowych typu CAD. Opisano w sposób ogólny funkcjonowanie wybranego programu. Do celów weryfikacji wykorzystano własną, analityczną metodę projektowania układów torowych. W analizie porównawczej rzędnych poziomych rozpatrzono trzy warianty układu geometrycznego zawierającego łuk koszowy z trzema...
-
Obliczanie przesunięć osi toru przy modernizacji łuków parabolicznych na liniach kolejowych
PublicationPodstawowym zadaniem modernizacji linii kolejowych jest właściwe zaprojektowanie nowego układu geometrycznego, który będzie spełniał założone kryteria związane z parametrami eksploatacyjnymi danej linii. Dążąc do spełnienia przyjętych warunków nałożonych na projektowany układ, projektant najczęściej koryguje podstawowe parametry geometryczne, tj. przechyłkę, promień łuku kołowego oraz długości krzywych przejściowych. W artykule...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...