displaying 1000 best results Help
Search results for: SENSORS
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 500 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Open Research DataThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Short-term measurement of physiological parameters - teenager (5 min) - 3.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (10 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) 7.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (20 min) 2.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (15 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)_3.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (10 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (30 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) 6.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (40 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (40 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 2.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 5.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (20 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 6.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (25 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 4.series
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Wojciech Chrzanowski dr hab. inż.
PeopleWojciech Chrzanowski was born in 1952 in Toruń. He completed his studies in Chemical Technology in 1975, getting his MSc in Inorganic Technology (specialty: Anti-Corrosion Protection) At the Faculty of Chemistry, Gdańsk University of Technology (with distinction). Later this year he was employed in the Department of Analytical Chemistry of then Institute of Chemical Engineering and Measuring Techniques, initially as a technical...
-
Comparison of Quality Evaluation of Agricultural Distillates Using Prototype of Electronic Nose and Fast/Flash GC
PublicationThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. In case of the prototype volatile fraction of the agricultural distillate was prepared via barbotage process. HERACLES II analysed the...
-
Comparison of different types of electronic nose instruments for evaluation of odour nuisance from landfill
PublicationThe paper presents and compares the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with six semiconductor sensors of TGS type. Classification of the air...
-
Distributed wireless sensor for measuring humidity and temperature
PublicationHumidity and temperature monitoring is often required in industrial halls and laboratories and can be crucial, because many properties of electrical devices deteriorates under influence of these parameters. There are several useful commercial methods for measuring humidity and temperature, such as commercial hygrometers and humidity recorders. However, they do not allow data acquisition simultaneously from multiple sensors. This...
-
Synergistic effect of multi walled carbon nanotubes and reduced graphene oxides in natural rubber for sensing application
PublicationUtilizing the electrical properties of polymer nanocomposites is an important strategy to develop high performance solvent sensors. Here we report the synergistic effect of multi walled carbon nanotubes (MWCNTs) and reduced graphene oxide (RGO) in regulating the sensitivity of the naturally occurring elastomer, natural rubber (NR). Composites were fabricated by dispersing CNTs alone and together with exfoliated RGO sheets (thermally...
-
Application of Web-GIS and Geovisual Analytics to Monitoring of Seabed Evolution in South Baltic Sea Coastal Areas
PublicationRegular surveys of coastal zone seabed deliver important information about geomorphologic processes such as silting of waterways. The recent introduction of the Sentinel series of sensors has allowed for the use of satellite sensing for shallow bathymetry morphology monitoring. In this context, this article presents a dedicated Geographic Information System for Baltic Sea shallow water depth monitoring on the basis of Sentinel-2...
-
Application of Multiplicative Drift Correction and Component Correction methods on simulated gas sensor array responses
PublicationSensor response drift is one of the most challenging problems in gas-analyzing systems. Such systems, commonly called electronic noses, are expected to be reliable and reproducible in the long term. Due to the drift phenomena, electronic noses usability is limited to the relatively short period of time, and frequent recalibrations of device are required. Because it is very hard to fabricate sensors without drift, this phenomenon...
-
GeoSPAR Project. Validation and selection methods of geoinformation analysis using GIS for ranking and forecasting of terrorist threats and criminal events
PublicationThe paper presents the description of work activities which have already been done within the first two stages – WorkPackage 1 and WorkPackage 2 - of the GeoSPAR Project. In such a context the general conceptual design of the GIS system and associate web service was presented and analysed. In addition, the operational and technical requirements for the GeoSPAR system have been specified and discussed; with special emphasis on system...
-
Induction motor control application in high-speed train electric drive
PublicationThe chapter presents an application of induction motor mechanical speed and load torque observers in high-speed train drives. The observers are applied for a 1.2-MW electric drive with an induction motor. The goal of using such observers is to utilize computed variables for diagnostic purposes of speed sensors and torque transmission system. The concept of diagnostic system is presented in this paper, and proper criteria are proposed....
-
Emotion Monitor - Concept, Construction and Lessons Learned
PublicationThis paper concerns the design and physical construction of an emotion monitor stand for tracking human emotions in Human-Computer Interaction using multi-modal approach. The concept of the stand using cameras, behavioral analysis tools and a set of physiological sensors such as galvanic skin response, blood-volume pulse, temperature, breath and electromyography is presented and followed...
-
HARDWARE AND SOFTWARE OF DIAGNOSTIC SYSTEM OF WHEELED TRACTORS = Hardwer i softwer systemu diagnostycznego ciągników kołowych
PublicationPodstawowym elementem systemu diagnostycznego jest komputer pokładowy Fujitsu FUTURO S100 z chłodzeniem pasywnym w wykonaniu odpornym na drgania i wstrząsy, z pamięcią Compact Flesh 16Gb. Do komputera dołączony jest monitor dotykowy NVOX LCD 10" VGA/FVAT. Oprogramowanie komputera obejmujesystem operacyjny Windows XP-2000, driver konwertera USB/DeviceNet oraz opracowany program diagnostyczny. Komputer połączony jest łączem USB z...
-
On Memory-Based Precise Calibration of Cost-Efficient NO2 Sensor Using Artificial Intelligence and Global Response Correction
PublicationNitrogen dioxide (NO2) is a prevalent air pollutant, particularly abundant in densely populated urban regions. Given its harmful impact on health and the environment, precise real-time monitoring of NO2 concentration is crucial, particularly for devising and executing risk mitigation strategies. However, achieving precise measurements of NO2 is challenging due to the need for expensive and cumbersome equipment. This has spurred...
-
Statistical Data Pre-Processing and Time Series Incorporation for High-Efficacy Calibration of Low-Cost NO2 Sensor Using Machine Learning
PublicationAir pollution stands as a significant modern-day challenge impacting life quality, the environment, and the economy. It comprises various pollutants like gases, particulate matter, biological molecules, and more, stemming from sources such as vehicle emissions, industrial operations, agriculture, and natural events. Nitrogen dioxide (NO2), among these harmful gases, is notably prevalent in densely populated urban regions. Given...
-
Pile Model Tests Using Strain Gauge Technology
PublicationOrdinary pile bearing capacity tests are usually carried out to determine the relationship between load and displacement of pile head. The measurement system required in such tests consists of force transducer and three or four displacement gauges. The whole system is installed at the pile head above the ground level. This approach, however, does not give us complete information about the pile-soil interaction. We can only determine...
-
Stanowisko wizualizacji zdarzeń w systemie STRADAR – realizacja i funkcje dla operatora
PublicationIt is crucial for the Border Guard to be equipped with a communication-teleinformatic infrastructure designed to support them in efficient realization of their operational tasks. STRADAR – a system which results are presented in this paper – is such an infrastructure. It is a distributed solution for the maritime division of the border guard. The system, with the use of a network of sensors located in both stationary and mobile...