Search results for: MH HYDRIDE ELECTRODE
-
The electrochemical response to glassy carbon electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the glassy carbon GC electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration,...
-
Influence of the analyzing window on electrode impedance measurement by the continuous frequency scanning method
Publication -
Solid-phase microextraction and ion chromatographic analysis of anions based on polypyrrole electrode
Publication -
Eucalyptus derived heteroatom-doped hierarchical porous carbons as electrode materials in supercapacitors
Publication -
Solid electrolyte gas sensors based on cyclic voltammetry with one active electrode
PublicationW artykule przedstawiono wyniki badań elektrokatalitycznego czujnika gazów toksycznych z jedną elektrodą aktywną.
-
Performance and Stability in H2S of SrFe0.75Mo0.25O3-δ as Electrode in Proton Ceramic Fuel Cells
PublicationThe H2S-tolerance of SrFe0.75Mo0.25O3-δ (SFM) electrodes has been investigated in symmetric proton ceramic fuel cells (PCFC) with BaZr0.8Ce0.1Y0.1O3-δ (BZCY81) electrolyte. The ionic conductivity of the electrolyte under wet reducing conditions was found to be insignificantly affected in the presence of up to 5000 ppm H2S. The fuel cell exhibited an OCV of about 0.9 V at 700 °C, which dropped to about 0.6 V and 0.4 V upon exposure...
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Influence of the analyzing window on electrode impedance measurement by thecontinuous freqency scanning method
PublicationPrzeprowadzono pomiary impedancyjne modelowego układu elektrycznego RC techniką ciągłego skanowania częstotliwościowego. Wyznaczono impedancję modelowego układu dla różnych okien analizujących oraz ich różnych wielkości. Wyznaczone dla różnych okien analizujących wartości R i C porównywano z wartościami rzeczywistymi. Stwierdzono wpływ rodzaju okna analizującego oraz jego długość na dokładność otrzymywanych wyników.
-
SEM image and EDS map of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with EDS map analysis results. This study were performed for better understanding the chemical composition of flat like structures that occurs in electrode. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion with different times and concentrations
Open Research DataThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K. DIfferent proteinase K concentrations and digestion times were evaluated, as described in subfolder names. The studies were performed before surface activation, during...
-
Electrode materials for electrochemical capacitors based on poly(3,4-ethylenedioxythiophene) and functionalized multi-walled carbon nanotubes characterized in aqueous and aprotic electrolytes
PublicationWithin this work, we report a facile one-stage synthesis of nanocomposites based on functionalized carbon nanotubes (CNTs) and electroactive polymer poly(3,4-ethylenedioxythiophene). Three different composites are investigated as potential electrode materials for the electrochemical capacitors. Two of the composites contain carbon nanotubes (ox-CNTs), functionalized by acid oxidation process (65% HNO3, 120 °C). The third composite...
-
Anna Danuta Dettlaff dr inż.
PeopleShe received her Master of Science degree in engineering with honours in 2013 at the Gdańsk University of Technology at the Department of Analytical Chemistry. In 2013-2017, she was a PhD student in the field of Chemical Technology at Faculty of Chemistry. Her doctoral dissertation was entitled “Nanocomposites based on conducting polymer and carbon materials for supercapacitor application”. In 2015, she was doing a three-month...
-
Higuchi fractal dimension analysis of surface EMG signals and determination of active electrode positions
Publication -
Carbon nanotubes decorated by mesoporous cobalt oxide as electrode material for lithium-ion batteries
Publication -
Application of the short time Fourier transformation to the continuous frequency method of measurement of electrode impedance
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest liniową funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego. Dokładność otrzymywanych wartości impedancji uwarunkowana jest wielkością okna i zastosowanej funkcji analizującej.
-
Development of iron doped strontium titanates as oxygen electrode for solid oxide fuel cells
PublicationProducing efficient solid oxide fuel cells (SOFC) without the use of harmful elements is one of the current challenges. Increasing the safety of people and reducing production costs is possible, among others, thanks to the use of iron doped strontium titanates as porous oxygen electrodes. In this thesis, the results of research on iron doped strontium titanates as potential oxygen electrodes for SOFC are presented. The research...
-
Electrode arrays applicable to EIT based mine detection: a comparison ofspatial sensitivity distribution.
PublicationPrzebadano trzy konfiguracje matryc elektrodowych. Określono optymalne wzorce pobudzeń oraz odpowiadające im rozkłady czułości.
-
AFM investigation of electrode fabricated by 3D printing
Open Research Data3D printing, also known as additive manufacturing, has enjoyed great interest in recent years due to the versatility of this method of producing various shapes and details. Due to the possibility of precise control of the shape and composition of the printed elements, the discussed technique can be widely used in electrochemistry, including electrochemical...
-
Comparison of Fluoride Ion-Selective Electrode Based Potentiometric Methods of Fluoride Determination in Human Urine
Publication -
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in Spike-Plate Multi-Electrode Electrostatic Precipitator
PublicationIn this work the results of electrohydrodynamic (EHD) secondary flowmeasurements in a spike-plate type electrostatic precipitator (ESP) are presented. In the investigated ESP two-sided and one-sided spike electrodes were used as a discharge electrodes. The results of 2D PIVmeasurements showed that flow pattern obtained for a different spike tips positions in respect to the primary flow direction significantly changing the flow...
-
Metrological characteristics of the flat voltammetric electrode in time domain with a reversible electrochemical reaction running on the surface
PublicationW artykule przedstawiono właściwości metrologiczne płaskich elektrod woltamperometrycznych. Omówiono wpływ napięcia polaryzującego na wartości parametrów charakteryzujących te elektrody.
-
Electrohydrodynamic secondary flow and particle collection efficiency in spike-plate multi-electrode electrostatic precipitator
PublicationIn this work the results of electrohydrodynamic (EHD) secondary flow measurements in a spike-plate type electrostatic precipitator (ESP) are presented. In the investigated ESP two-sided and one-sided spike electrodes were used as a discharge electrodes. The results of 2D PIV measurements showed that flow pattern obtained for a different spike tips positions in respect to the primary flow direction significantly changing the flow...
-
Harmonic analysis of the current of an electric system simulating the electrode process in conditions of linearly changing potential
PublicationAnalizowany był prąd elektrycznego modelu symulującego pierwszorzędową reakcję elektrodową zachodzącą w warunkach liniowo zmieniającego się potencjału z nałożonym sygnałem sinusoidalnym. Pokazano, że transformacja Fouriera nie odzwierciedla zmian amplitudy składowych komponentów w funkcji potencjału. Także matematycznie wykazano, że zastosowanie transformacji Gabora do analizy spektralnej pozwala uzyskać poprawną dekompozycję częstotliwościową....
-
sp2-rich dendrite-like carbon nanowalls as effective electrode for environmental monitoring of explosive nitroaromatic
PublicationNitroaromatic compounds are commonly used explosive materials that pose a risk to human health and ecosystems due to their acute toxicity and carcinogenicity. Nitroaromatics have numerous pathways into the environment via discarded munitions (e.g. into the Baltic Sea after World War II), after use in mining operations, and in industrial run-off from factories producing these compounds (which are produced across the world to date)....
-
Reactions of solute species at an electrode modified with titanocene functionalized polypyrrole film: ferrocene and titanocene dichloride
PublicationPo raz pierwszy zbadano możliwość intermediacji ładunku poprzez centra tytanocenowe polimeru modyfikowanego chemicznie związanymi grupami dichloro tytanocenowymido polipirolu. Badano reakcje elektrodowe ferrocenu i dichlorotytanocenu. Wykazano aktywność elektrodową w zakresie potencjałów redoks pary Ti(IV/TiIII)w stosunku do reakcji redoks ferrocenu i reakcji dichlorotytanocenu. Wykazano, że centra TcCl2 polimeru są zadowalająco...
-
SEM image and line EDS of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with line EDS analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 20 kV in a high vacuum mode. The chemical compositions of the investigated powder...
-
Distribution of Relaxation Times analysis results of impedance of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C) as a function of measuring temperature at 0.1% pO2
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode as a function of measuring temperature at 0.1% pO2. Electrode was sintered at 1000 °C and measured at different temperatures (800 °C, 750 °C, 700 °C).
-
Distribution of Relaxation Times analysis results of impedance of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C) as a function of oxygen partial pressure at 800 °C
Open Research DataThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode as a function of oxygen partial pressure at 800 °C. Electrode was sintered at 1000 °C and measured at different oxygen partial pressures (10% pO2, 1% pO2, 0.1% pO2).
-
Oxygen partial pressure and temperature dependence of Gerischer element of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of Gericher element at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C)and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent circuit...
-
Oxygen partial pressure and temperature dependence of series resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of series resistance (R) at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Electrochemical oscillations and bistability during anodic dissolution of vanadium electrode in acidic media—part I. Experiment
Publication -
The effect of a polyharmonic structure of the perturbation signal on the results of harmonic analysis of the current of a first-order electrode reaction
Publication -
The fixed state in impedance measurements of a two-step electrode reaction proceeding with accompanying adsorption of an intermediate product
Publication -
Pyrrole azocrown ethers. Synthesis, complexation, selective lead transport and ion-selective membrane electrode studies
PublicationOtrzymano nowe, 21-członowe, lipofilowe etery koronowe z jednostką pirolową i dwoma grupami azowymi jako składowymi makrocyklu. Właściwości kompleksujące tych nowych oraz dwóch wcześniej otrzymanych makrocykli zbadano w acetonitrylu. Ligandy te zostały użyte jako jonofory w badaniach konkurencyjnego transportu równomolowej mieszaniny jonów metali: Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Ag2+, Pb2+ w układzie woda(pH 4.9)/chloroform/woda(pH...
-
Synthesis and electrode properties of 19-membered azo- and azoxycrown ethers. Structure of dibenzo-19-azocrown-7
PublicationW artykule opisano syntezę 19-członowych azo i azoksykoron oraz strukturę dibenzo-19-azokorony-7. Przedstawiono badania elektrodowe niektórych otrzymanych związków. Stwierdzono, że związki są czułe na jony talu (I).
-
Carbon Paste Electrode Modified with ZrO2 Nanoparticles and Ionic Liquid for Sensing of Dopamine in the Presence of Uric Acid
Publication -
Tailoring the Stability of Ti-Doped Sr2Fe1.4TixMo0.6−xO6−δ Electrode Materials for Solid Oxide Fuel Cells
Publication -
SEM images of symmetrical cell interface with SrTi0.30Fe0.70O3-d electrode and CGO-20 substrate in function of sintering temperature
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with SrTi0.30Fe0.70O3-d electrode and CGO-20 substrate in function of sintering temperature (800 °C, 900°C and 1000 °C) . Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage...
-
SEM images of symmetrical cell interface with SrTi0.65Fe0.35O3-d electrode and CGO-20 substrate in function of sintering temperature
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with SrTi0.65Fe0.35O3-d electrode and CGO-20 substrate in function of sintering temperature (800 °C, 900°C and 1000 °C) . Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage...
-
SEM images of symmetrical cell interface with SrTi0.50Fe0.50O3-d electrode and CGO-20 substrate in function of sintering temperature
Open Research DataThis dataset contains images of polished cross section of symmetrical cell interface with SrTi0.50Fe0.50O3-d electrode and CGO-20 substrate in function of sintering temperature (800 °C, 900°C and 1000 °C) . Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage...
-
Oxygen partial pressure and temperature dependence of series resistance of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Open Research DataThis dataset contains values of equivalent circuit element series resistance at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Oxygen partial pressure and temperature dependence of low frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of low frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of middle frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of middle frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of low frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of low frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of middle frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Open Research DataThis dataset contains values of middle frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oznaczanie tlenu – od metody Winklera do czujników enzymatycznych (Determination of oxygen – from Winkler Method to enzymatic sensor)
PublicationMonitoring of dioxygen levels is of utmost importance from the view-point of life processes, medical diagnostics, nutrition and chemical industries. In all these measurements both low and high levels of this element are important. The common methods for the determination of dioxygen are the Winkler method, Clark electrode and pulsoxymeters. A new, already strong field of research can be now recognized – the development of miniaturized...
-
Influence of sintering temperature of porous SrTi0.30Fe0.70O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Influence of sintering temperature of porous SrTi0.50Fe0.50O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Influence of sintering temperature of porous SrTi0.65Fe0.35O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Open Research DataThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublicationThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...