Filters
total: 2763
-
Catalog
- Publications 1955 available results
- Journals 15 available results
- Conferences 5 available results
- People 48 available results
- Projects 14 available results
- Laboratories 3 available results
- Research Teams 3 available results
- Research Equipment 3 available results
- e-Learning Courses 88 available results
- Events 2 available results
- Open Research Data 627 available results
displaying 1000 best results Help
Search results for: 3D BODY SCANNING
-
Assessment of User Mobility’s Influence on System Loss in Several Body-to-Body Scenarios
PublicationIn this paper, Body-to-Body communications in indoor and outdoor environments for different on-body antenna configurations and different mobility scenarios were studied, based on system loss measurements at 2.45 GHz. The main objective is to properly characterise the influence of the Transmitter-Receiver configuration on system loss and fast fading behaviour, the latter being modelled by the Rice Distribution. Globally, it is observed...
-
Fading Modelling in Dynamic Off-Body Channels
PublicationThis paper presents an off-body fading channel model for Body Area Networks (BANs) in indoor environments. The proposed model, which is based on both simulations and measurements in a realistic environment, consists of three components: mean path loss, body shadowing, and multipath fading. Seven scenarios in an indoor environment (a medium-size room with furniture, mostly consisting of wooden tables and chairs) have been measured:...
-
POMIAROWE BADANIA PROPAGACYJNE W SIECIACH WBAN TYPU BODY-TO-BODY
PublicationW referacie zaprezentowano pomiary tłumienia propagacyjnego w sieciach WBAN typu body-to-body, pracujących przy częstotliwości 2,45 GHz, dla zróżnicowanych scenariuszy i środowisk badawczych. Wstępna analiza wyników pomiarów, bazująca na wartości średniej i odchyleniu standardowym tłumienia propagacyjnego wykazała, że wartości te są zależne od wzajemnego położenia anteny nadawczej i odbiorczej, a także od typu scenariusza dynamicznego...
-
Performance of a new commercial high-definition 3D patient specific quality assurance system for CyberKnife robotic radiotherapy and radiosurgery
PublicationConventional two dimensional and low-definition measurement techniques for dosimetric verification of radiotherapy treatment deliveries are no longer adequate in the era of hypofractionation and extremely high dose gradients. New quality assurance (QA) tools with 3D capability and high definition are urgently needed. The purpose of this study was to evaluate the performance of one of the first such commercial systems as applied...
-
On the correspondence between two- and three-dimensional Eshelby tensors
PublicationWe consider both three-dimensional (3D) and two-dimensional (2D) Eshelby tensors known also as energy–momentum tensors or chemical potential tensors, which are introduced within the nonlinear elasticity and the resultant nonlinear shell theory, respectively. We demonstrate that 2D Eshelby tensor is introduced earlier directly using 2D constitutive equations of nonlinear shells and can be derived also using the throughthe-thickness...
-
Computing methods for fast and precise body surface area estimation of selected body parts
PublicationCurrently used body surface area (BSA) formulas give satisfactory results only for individuals with typical physique, while for elderly, obese or anorectic people accurate results cannot be expected. Particularly noteworthy are the results for individuals with severe obesity (body-mass index greater than 35 kg/m2), for which BSA estimation errors reached 80%. The main goal of our study is the development of precise BSA models for...
-
Thermal stability analysis of poly(lactic acid)-carbon black-nanodiamond composite
Open Research DataThis dataset contains thermal stability tests carried out on new 3D printing-dedicated composites with poly-lactic acid (PLA), carbon black (CB) and nanodiamond fillers. Two types of nanodiamonds were studied: detonation nanodiamonds (DND) and boron-doped carbon nanowalls (BCNW). The investigated techniques include: thermogravimetric analysis (TGA)...
-
Measurements of Path Loss in Off-Body Channels in Indoor Environments
PublicationThis paper presents a measurements of the path loss for validation of a statistical model for off-body radio channels in an indoor multipath environment, which considers the distance dependent mean path loss, and describes body shadowing and fast fading components in a statistical way. The measurement equipment and propagation indoor environment have been presented. Two different bodies and five static and two walking scenarios...
-
Multichannel Human Body Communication
PublicationHuman Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog...
-
A comprehensive evaluation of flexible FDM/FFF 3D printing filament as a potential material in medical application
PublicationThe use of FDM/FFF in 3D printing for medical sciences is becoming common. This is due to the high availability and decent price of both 3D printers and filaments useful for FDM/FFF. Currently, researchers' attention is focused mainly on the study of medical filaments based on PLA, PCL or their modifications. This contributes to insufficient diversity of medical-grade filaments on the market. Moreover, due to the lack of specified...
-
System Loss Model for Body-to-Body Networks in Indoor and Outdoor Environments
PublicationA system loss model for body-to-body networks in indoor and outdoor environments is proposed in this paper, based on measurements taken at 2.45 GHz. The influence of the type of environment, antenna visibility and user mobility on model parameters has been investigated. A significant impact of mutual antennas’ placement and their visibility is shown. The proposed model fits well to empirical data, with the average root mean square...
-
Wideband Channel Measurements for Polarised Indoor Off-Body Communications
PublicationThis paper presents the initial results of wideband channel measurements for polarised off-body communication at 5.8 GHz, in an indoor environment. Channel Impulse Response measurements were performed simultaneously for two orthogonal polarisations of the wearable antenna, and repeated for vertical and horizontal orientations of the off-body one. Four types of measurement scenarios were considered in order to investigate the influence...
-
Badania i analiza zaników w sieciach WBAN typu body-to-body pracujących w różnych środowiskach propagacyjnych
PublicationPrzedstawiono badania zaników w sieciach WBAN typu body-to-body, oparte na wynikach pomiarów tłumienia systemowego przeprowadzonych w zamkniętym i otwartym środowisku propagacyjnym przy częstotliwości 2,45 GHz. Analiza statystyczna wyników dowiodła, że zaniki szybkozmienne najlepiej odzwierciedla rozkład Nakagamiego-m, natomiast zaniki wolnozmienne można opisać rozkładem log-normalnym.
-
Mobility’s Influence on System Loss in Off-Body BAN Scenarios
PublicationIn this paper, a measurement campaign for off body communications in an indoor environment is investigated for a set of on-body antennas. The channel impulse response was measured with the user approaching and departing from an off-body fixed antenna using two user dynamics, standing at fixed positions and walking. The processing of the measurement data allowed to evaluate system loss statistics. Different antenna configurations...
-
Proposal of a System Loss Model for Body Area Network in Passenger Ferry Environment
PublicationIn the paper, proposal of an empirical off-body system loss model for Body Area Networks working in a passenger ferry environment at 2.45 GHz has been presented. The measurements were carried out for dynamic scenarios in the discotheque passenger ferry environment. The general model formula consists of three components: mean system loss, attenuation resulting from the variable antenna position on the human body, and attenuation...
-
Impact of radio wave polarisation on off-body communications in indoor environments
PublicationThis paper describes the measurements and the analysis of the impact of radio wave polarisation on off-body communications in Body Area Networks in indoor environments. Measurements on polarisation impact are briefly described. Five investigated scenarios with different body postures and different antenna placements are characterised. The difference between the vertical and horizontal components of the received radio signal are...
-
Radio Channel Measurements in Off-Body Communications in a Ferry Passenger Cabin
PublicationThis paper presents an off-body radio channel measurements in a ferry passenger cabin at 2.45 GHz band, for static sleeping scenarios with different body orientation and on-body antennas placements, and also for upper and lower sleeping berths. The measurements have been performed with two types of on-body wearable receiving antennas: FlexPIFA (flexible planar inverted F antenna), and FlexNotch (flexible adhesive-backed notch antenna)...
-
User Mobility’s Influence on System Loss in Off-Body BAN Scenarios
PublicationIn this paper, a measurement campaign for off-body communications in an indoor environment is investigated for a set of on-body antennas. The channel impulse response was measured with the user approaching and departing from an off-body fixed antenna using two user dynamics: standing at fixed positions and walking. The processing of the measurement data allowed to evaluate system loss statistics. Different antenna configurations...
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
The morphology of V2O5 nanostructures deposited on quartz glass
Open Research DataThe DataSet contains the confocal microscope images of morphology evolution of vanadium pentaoxide nanostructures on quartz glass obtained by annealing as-prepared films at 500C and 600C under synthetic air.