Search results for: CALIBRATION
-
Mechanical characterization of a gravel column in a calibration chamber operating as a triaxial cell
PublicationA series of tests considering the behavior of gravel columns was performed. A segment of column with a height of 1 m and a diameter of 0.53 m was modelled in a calibration chamber used as a triaxial cell at three different lateral stress applied. The vertical load transferred on the column head was simulated with steady increase of water pressures in the upper and lower membranes. During the loading the volumetric changes in the...
-
Calibration-Free Single-Anchor Indoor Localization Using an ESPAR Antenna
PublicationIn this paper, we present a novel, low-cost approach to indoor localization that is capable of performing localization processes in real indoor environments and does not require calibration or recalibration procedures. To this end, we propose a single-anchor architecture and design based on an electronically steerable parasitic array radiator (ESPAR) antenna and Nordic Semiconductor nRF52840 utilizing Bluetooth Low Energy (BLE)...
-
Verification of ESPAR Antennas Performance in the Simple and Calibration Free Localization System
PublicationThis paper presents the results of simulations and measurements of an indoor localization system that uses Electronically Steerable Parasitic Array Radiator (ESPAR) antennas with switched directional beam. Proposed antennas are dedicated for 2.4GHz ISM low-cost applications where determination of the incoming signal is required. The antennas performance is analyzed and verified with relation to positioning methods based on the...
-
Effect of salinity and pH on the calibration of the extraction of pharmaceuticals from water by PASSIL
Publication -
Calibration of Passive Samplers for the Monitoring of Pharmaceuticals in Water-Sampling Rate Variation
Publication -
<title>Diagnostic and calibration system for the CMS RPC muon trigger</title>
Publication -
Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water
PublicationNa Univeristy of Portsmouth (UK) opracowano próbnik pasywny typu Chemcatcher, który może być stosowany do długotrwałego monitoringu organicznych zanieczyszczeń wody. Na działanie wszystkich próbników pasywnych wpływ mają warunki środowiskowe takie jak np. ruch wody czy temperatura. Przed użyciem próbnika Chemcatcher w badaniach polowych wymagana więc była wcześniejsza kalibracja w laboratorium. Przedstawiono wyniki serii doświadczeń...
-
A novel calibration method for RSS-based DoA estimation using ESPAR antennas
PublicationIn this paper, we introduce a new calibration method that can successfully be used in direction of arrival (DoA) estimation using electronically steerable parasitic array radiator (ESPAR) antennas and employing power-pattern cross-correlation (PPCC) algorithm, which relies on received signal strength (RSS) values recorded at the antenna output port. Instead of the commonly used two-step approach, during which ESPAR antenna calibration...
-
ECU calibration for gaseous dual fuel supply system in compression ignition engines
PublicationThe dual fuel (DF) combustion mode is proven solution that allows to improve or get at the same level engine performance and reduce toxic compounds in exhaust gases which is confirmed by researchers and end-users. DF combustion mode uses two fuels gaseous fuel as a primary energy source and a pilot quantity of diesel fuel as ignition source. However, in order, to fully take advantage of the potential of the dual fuel mode, DF system...
-
Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors
PublicationMonitoring air pollution is a critical step towards improving public health, particularly when it comes to identifying the primary air pollutants that can have an impact on human health. Among these pollutants, particulate matter (PM) with a diameter of up to 2.5 μ m (or PM2.5) is of particular concern, making it important to continuously and accurately monitor pollution related to PM. The emergence of mobile low-cost PM sensors...
-
Application of auto calibration and linearization algorithms to improve sound quality of computer devices
PublicationAn application of auto calibration and linearization algorithms designed for correcting acoustic characteristics of selected computer devices was presented in the paper. The functionality of the algorithms were presented for two kind of computer devices: ultrabook class computer and portable device of All-In-One type. The algorithms were adjusted for the given type of the device on the basis of series of measurements conducted...
-
Experiments and calibration of a bond-slip relation and efficiency factors for textile reinforcement in concrete
PublicationTextile reinforcement yarns consist of many filaments, which can slip relative each other. At modelling of the global structural behaviour, interfilament slip in the yarns, and slip between the yarns and the concrete can be considered by efficiency factors for the stiffness and strength of the yarns, and by applying a bond-slip relation between yarns and concrete. In this work, an effective and robust method for calibration of...
-
A New Approach to Generation of Standard Gas Mixtures used in the Calibration of Gas Analysers
Publication -
Calibration of permeation passive samplers with silicone membranes based on physicochemical properties of the analytes.
PublicationW pracy opisano sposób kalibracji pasywnych dozymetrów permeacyjnych, wykorzystywanych w badaniach powietrza w oparciu o własności fizyko-chemiczne analitów. Stwierdzono silną zależność pomiędzy stałą kalibracyjną (K) dozymetrów i liczbą atomów węgla w cząsteczce analitu (w obrębie danej grupy związków chemicznych) dla alkoholi, alifatycznych i aromatycznych węglowodorów oraz estrów. Taka zależność występuje również pomiędzy...
-
Calibration of the CMS drift tube chambers and measurement of the drift velocity with cosmic rays
Publication -
Colvolutional calibration of AFM probe
Open Research DataAtomic force microscopy is based on the interaction of the examined surface with a probe of a pyramidal shape, tipped with a sharp end with a radius of curvature ranging from single nanometers to hundreds of nanometers. The resolution of the obtained image is of course dependent on the above-mentioned geometric size, and the resulting image is a convolutional...
-
Spatial Calibration of a Dual PTZ-Fixed Camera System for Tracking Moving Objects in Video
PublicationA dual camera setup is proposed, consisting of a fixed (stationary) camera and a pan-tilt-zoom (PTZ) camera, employed in an automatic video surveillance system. The PTZ camera is zoomed in on a selected point in the fixed camera view and it may automatically track a moving object. For this purpose, two camera spatial calibration procedures are proposed. The PTZ camera is calibrated in relation to the fixed camera image, using interpolated...
-
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...
-
Sensitivity calibration procedures in optical‐CT scanning of BANG®3 polymer gel dosimeters
Publication -
New procedure of silica gel surface modification. Preparation of gaseousstandard mixtures for calibration purposes.
PublicationPrzedstawiono nową procedurę modyfikacji powierzchni żelu krzemionkowego z wykorzystaniem trimetyloaminy jako odczynnika. Próbki chemiczne modyfikowanego nośnika zostały wykorzystane do sporządzenia gazowych mieszanin wzorcowych (chlorek metylu jako składnik mierzony) techniką termicznego rozkładu związków powierzchniowych. Głównym celem badań było sprawdzenia przydatności nowej procedury modyfikacji powierzchni żelu do...