Filters
total: 26
Search results for: PDMS
-
Impact of Plasma Pre-Treatment on the Tribological Properties of DLC Coatings on PDMS Substrates
Publication -
Application of the chromatographic retention index system for theestimation of the calibration constants of permeation passivesamplers with polydimethylsiloxane membranes
PublicationW pracy przedstawiono wyniki badań z zastosowaniem pasywnych dozymetrów typu permeacyjnego, wyposażonych w membrany wykonane z PDMS. Badania dotyczyły oszacowania wartości stałych kalibracyjnych dozymetrów przy wykorzystaniu systemu indeksów retencji, wyznaczanych chromatograficznie, w warunkach liniowego narostu temperatury pracy kolumny (LTPRI). Znaleziono korelację pomiędzy wartościami stałych kalibracyjnych próbników typu pasywnego,...
-
Pervaporation of volatile organohalogen compounds throughpolydimethylsiloxane membrane
PublicationThe objective of this work was to apply dense polymeric membranes for pervaporation of tetrachloroethene from aqueous solution. Three membranes were evaluated: polydimethylsiloxane (PDMS-PV1 and PDMSPV2) membranes, and a PDMS with ZSM-5 zeolite filled (PERVAP-1070) membrane. The effect of feed composition on flux and selectivity was also investigated. Tested membranes showed good properties in the separation of tetrachloroethylene,...
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Direct solid phase microextraction combined with gas chromatography – Mass spectrometry for the determination of biogenic amines in wine
PublicationA direct method based on immersion solid phase microextraction (DI-SPME) gas chromatography mass-spectrometry (GC-MS) was optimized and validated for the determination of 16 biogenic amines in Polish wines. In the analysis two internal standards were used: 1,7-diaminoheptane and bis-3-aminopropylamine. The method allows for simultaneous extraction and derivatization, providing a simple and fast mode of extraction and enrichment....
-
Nowoczesne techniki przygotowania próbki do oznaczania analitów organicznych z zastosowaniem chromatografii gazowej. Część I. Podstawy teoretyczne ekstrakcji. Modern techniques of preparation of samples for determining organic analytes by gas chromatography. Part I. Theoretical principles of extraction.
PublicationPrzedstawiono podstawy teoretyczne technik izolacji i wzbogacania analitów organicznych z próbek gazowych oraz ciekłych. Już pobieżna analiza literatury dotyczącej omawianych zagadnień, pokazuje jak różnorodne i bogate spektrum technik jest stosowane na etapie przygotowania próbki. Z drugiej strony, z punktu widzenia podstaw fizykochemicznych, większość technik opiera się na dwóch zjawiskach: adsorpcji analitów na medium zatrzymującym...
-
Full scattering profile of circular optical phantoms mimicking biological tissue
PublicationHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. In our poster, we suggest a new type of skin phantom and an optical method for sensing physiological tissue condition, basing on the collection of the ejected light at all exit angles, to receive the full scattering profile. Conducted experiments were carried out on an unique set-up for noninvasive encircled measurement. Set-up consisted...
-
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublicationThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
Evaluation of polycaprolactone as a new sorbent coating for determination of polar organic compounds in water samples using membrane–SPME
PublicationCommercially available solid-phase microextraction fibers used for isolation of polar analytes are based on the adsorption phenomenon. In consequence, typical limitations bonded with analytes displacement and matrix effects are very frequent. In the present study, alternative solution is described. Polycaprolactone (PCL) was used for the first time as sorbent to isolate polar organic compounds from water samples using the membrane–solid-phase...
-
‘Green’ multi - residue methods for the determination of high importance currently used pesticides in environmental samples
PublicationThe purpose of the research has been to develop and apply ‘green’ analytical methodologies to control and monitor the level of currently used pesticides from different chemical groups in aqueous samples. For extraction of analytes solid - phase microextraction (SPME) and dispersive liquid - liquid microextraction (DLLME) have been applied and compared. For SPME, commonly used materials for coating fibers include: polydimethylsiloxane...
-
Development of thin film SPME sorbents based on deep eutectic solvents and their application for isolation and preconcentration of endocrine-disrupting compounds leaching from diapers to urine
PublicationIn this study, the thin film solid phase microextraction (TF-SPME) based on a novel sorbent composed of deep eutectic solvent (DES) is proposed. Among several synthesized sorbents the most efficient was DES containing trihexyl(tetradecyl)phosphonium chloride and docosanol mixed with polydimethylsiloxane (PDMS) in a molar ratio 1:3:0.25 to achieve a more stable structure. The proposed sorbent was applied on a fiberglass mesh and...
-
Partition coefficients of selected environmentally important volatile organic compounds determined by gas - liquid chromatography with polydimethylsiloxane stationary phase
PublicationPrzedstawiono wartości współczynników podziału (stałych podziału) 14 lotnych związków organicznych istotnych dla stanu środowiska (często oznaczanych w powietrzu w pomieszczeniach zamkniętych) między fazą gazową (N2) a ciekłą (PDMS). Wyznaczano je dwiema technikami (izotermiczną i z liniowo programowanym wzrostem temperatury). Dowiedziono, że istnieje możliwość wyznaczania współczynników podziału techniką LTPRI w oparciu o skalę...
-
Optical Parameters Stability Over Time of Porous Phantoms Mimicking Tissues
Open Research DataOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom...
-
A comparative study of the performance of passive samplers
PublicationPodstawowym celem podjętych badań było porównanie pracy dozymetrów pasywnych wykorzystywanych na etapie izolacji i wzbogacania lotnych związków organicznych z powietrza atmosferycznego na terenie aglomeracji Trójmiejskiej. Jako próbniki do pobierania próbek analitów zastosowano komercyjne dozymetry pasywne typu dyfuzyjnego (Radiello i Orsa 5) oraz dozymetry typu permeacyjnego własnej konstrukcji wyposażone w półprzepuszczalną membranę...
-
Elektrochemiczny gazowy czujnik na bazie cieczy jonowej do oznaczania benzaldehydu
PublicationW pracy przedstawiono wyniki badań dotyczące opracowania dwóch wersji prototypowego, laboratoryjnego elektrochemicznego czujnika do oznaczania par benzaldehydu. Elektrolitem w tych czujnikach była ciecz jonowa [HMIM][Tf2N] (bis(trifluorometylosulfonylo)imidek 1-heksylo,3-metyloimidazolinowy). Jeden z czujników zbudowany był wg koncepcji Clarka z membraną PDMS, drugi z użyciem komercyjnych elektrod firmy DropSens Co. W obu wersjach,...
-
Nanoparticle-free tissue-mimicking phantoms with intrinsic scattering
PublicationWe present an alternative to the conventional approach, phantoms without scattering nanoparticles, where scattering is achieved by the material itself: spherical cavities trapped in a silicone matrix. We describe the properties and fabrication of novel optical phantoms based on a silicone elastomer polydimethylsiloxane (PDMS) and glycerol mixture. Optical properties (absorption coefficient µa, reduced scattering coefficient µs',...
-
A Measurement System for Quasi-Spectral Determination of Absorption and Scattering Parameters of Veterinary Tissue Phantoms
PublicationThis paper describes the construction of a system for the quasi-spectral determination of absorption and scattering parameters of animal tissue phantoms. Several tissue phantoms, including one reference and two modified for examination, were prepared from polydimethylsiloxane (PDMS). The phantoms were measured using a system based on an integrating sphere and the light sources of wavelengths commonly used for the treatment of various...
-
Photoinduced and thermal oxidation of rapeseed and sunflower oils
PublicationCelem prezentowanych badań było porównanie stabilności oksydatywnej olejów rzepakowych i słonecznikowych. Na etapie przyspieszania utleniania zastosowano promieniowanie UV. Po naświetlaniu lotne produkty utlenienia były izolowane z fazy nadpowierzchniowej przy pomocy mikroekstrakcji do fazy stacjonarnej HS-SPME(włókno DVB/CAR/PDMS) i oznaczane z zastosowaniem chromatografii gazowej z detektorem płomieniowo-jonizacyjnym (GC/FID)....
-
Application and optimization of headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography - flame-ionization detector (GC-FID) to determine products of the petroleum industry in aqueous samples
PublicationA simple and solvent-free analytical method has been optimized for the determination of hydrocarbons (C6 - C20) from products of the petroleum industry in aqueous samples. Extraction and analysis was carried out using headspace solid-phase microextraction (HS-SPME) and gas chromatography coupled with flame-ionization detector (GC-FID). A ZB-5 capillary column (30 m × 0.25 mm inner diameter, 0.25 µm film thickness) was used for...