Search results for: biodegradable metallic implant
-
Conducting polymers for biodegradable metallic implants
PublicationNowadays permanent metallic cardiovascular stents are long-term implants. The long-time presence of such an implant in human body can cause overgrowth of tissue within the treated portion of the vessel, blockage of the circulatory system and many other clinical complications, such as thrombosis, prolonged physical irritations or chronic inflammation. Therefore, in recent years, there is an interest to create biodegradable metallic...
-
Conducting polymer films for biodegradable metallic cardiovascular stents
PublicationIn recent years, there is increasing interest to create biodegradable metallic cardiovascular stents instead of using their permanent form. The most interesting materials for this purpose are iron and its alloys. However, in order to use it in clinical application, their degradation rate and biological performance need to be optimized. One promising solution is coating the metal with conducting polymer films. In this work, short...
-
Electrophoretic deposition and characterization of composite chitosan/Eudragit E 100 or poly(4-vinylpyridine)/mesoporous bioactive glass nanoparticles coatings on pre-treated titanium for implant applications
PublicationTitanium implants are surface-modified to achieve bioactivity and often antibacterial properties. Such surface coatings may increase corrosion degradation and be weakly attached to the substrate. In the present research, biodegradable composite coatings, investigated so far as smart environment-sensitive, slowly releasing silver to the implant neighborhood, were produced as a combination of chitosan (CS) with Eudragit E 100 (EE100)...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublicationResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Structural changes of bacterial cellulose due to incubation in conditions simulating human plasma in the presence of selected pathogens
PublicationBacterial nanocellulose (BNC) is a natural biomaterial with a wide range of medical applications. However, it cannot be used as a biological implant of the circulatory system without checking whether it is biodegradable under human plasma conditions. This work aimed to investigate the BNC biodegradation by selected pathogens under conditions simulating human plasma. The BNC was incubated in simulated biological fluids with or...
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Investigations of Titanium Implants Covered with Hydroxyapatite Layer
PublicationTo reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention...
-
Marcin Wekwejt dr inż.
PeopleMarcin Wekwejt holds a bachelor’s degree in Biomedical Engineering (2016; J. and J. Śniadecki Bydgoszcz University of Technology & L. Rydygier Collegium Medicum), a master’s degree in Mechanical-Medical Engineering (2018; Gdańsk University of Technology & Gdańsk Medical University), and a PhD in Materials Engineering (2021; Gdańsk University of Technology). He was awarded the title of Doctor of Engineering and Technical...
-
Electrophoretic Deposition of Chitosan/Eudragit E 100/AgNPs Coatings for Controlled Release of Antibacterial Substance
PublicationThe development of bacterial infection of the tissues surrounding an implant is one of the leading causes of implant surgery failure. In order to prevent the deposition of bacteria on the implant surface and the formation of biofilm, coatings that exhibit antibacterial properties are manufactured. However, the problem is the controlled release of the therapeutic substance from the coating over the extended life of the implant [1],...
-
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublicationDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Influence of Surface Modification of Titanium and Its Alloys for Medical Implants on Their Corrosion Behavior
PublicationTitanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment,...
-
Bioactive core material for porous load-bearing implants
PublicationSo far state of knowledge on biodegradable materials is reviewed. Among a variety of investigated materials, those composed of polymers and ceramics may be considered as only candidates for a core material in porous titanium alloy. The collagen and chitosan among natural polymers, polyhydroxy acids among synthetic polymers, and hydroxyapatite and tricalcium phosphate among ceramics are proposed for further research. Three essential...
-
The biological reactions on the implant-organism border
PublicationMateriał przeznaczony do implantacji w tkanki żywego organizmu powinien być biozgodny i biofunkcjonalny. Jeśli tak nie jest, ciało reaguje stanem zapalnym. Reakcje zapalne mogą się objawiać np. odrywaniem się cząstek materiału z powierzchni implantu na skutek tarcia lub nacisku, lub wytworzeniem biofilmu na jego powierzchni.
-
Degradation of implantable materials – in vivo and in vitro research
PublicationThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
Robert Bogdanowicz dr hab. inż.
PeopleRobert Bogdanowicz received his Ph.D. degree with honours in Electronics from the Gdansk University of Technology. He worked as a post-doc researcher in Ernst-Moritz-Arndt-Universität Greifswald Institut für Physik. He has initiated optical emission imaging of muti-magnetron pulsed plasma and contributed to the development of antibacterial implant coatings deposited by high-power impulse magnetron sputtering. He moved back to...
-
Surgical implant used in ventral hernia repair subjected to physiological pressure - computer simulation
PublicationW streszczeniu przedstawiono matemayczny model implantu wszczepionego pacjentowi podczas laparoskopowej naprawy przepukliny brzusznej. Wykonano go z użyciem metody elementów skończonych. Przyjęto ortotropowy model materiałowy implantu.
-
Degradation of metallic implants
PublicationPresence of metallic implants made of stainless steels, Co and Ti alloys is sometimes followed by some undesired allergic reactions and inflammatory processes and consequently the necessity of reimplantation.
-
Developing Materials for Biodegradable Otolaryngological Stents
PublicationMaterials for otolaryngological stents have to be characterized by good tensile strength, wear resistance, biocompatibility, and specific degradation time. This work aimed to synthesize polyurethanes based on various biodegradable polyol blends. Their biodegradability and mechanical properties were tested and compared to commercial BIOFLEX material.
-
Biodegradable Polymer Packaging Materials in Seawater Environment
PublicationIn this chapter, our interest is directed into dea/ocean/lakes biodegradable environment for polymer packaging materials from two different points of view.
-
Biodegradable polymer packaging materials - influence on environment
PublicationAwareness of the waste problem and its impact on the environment has awakened new interest in the area of biodegradable polymers. Biodegradation of various polymers have been studied under diverse environments like in soil, in sewage sludge, in compost conditions and in sea water by different research groups. The aim of this paper is to present the research methods on the biodegradation of the commercially available biodegradable...
-
Allergy to implant components: chromium, nickiel, cobalt and titanium
PublicationImplant jest kompozycja roznych pierwiastkow: niklu, chromu, kobaltu, tytanu, molibdenu i wanadu. Pierwiastki te moga doprowadzic do alergii, egzemy i obluzowania implantu.
-
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublicationThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
X-Ray diffraction of the metallic nanostructures
Open Research DataMetallic nanostructures (gold and silver) were manufactured as a thermal annealing of gold or silver thin film. Gold films with thickness of 2.8 nm were deposited on a silicon substrates using a table-top dc magnetron sputtering coater (EM SCD 500, Leica), equipped with quartz microbalance for in-situ thickness measurements. Films were deposited from...
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublicationAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [3300730069445181]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541212901]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541212601]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541212331]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541214921]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541214991]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541219801]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 40 - Tissue image [10040729541211191]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 42 - Tissue image [10040729541217341]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 42 - Tissue image [10040729541212031]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 42 - Tissue image [10040729541219141]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Breast implant-associated anaplastic large cell lymphoma - Female, 42 - Tissue image [10040729541216851]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Tailoring the electrochemical degradation of iron protected with polypyrrole films for biodegradable cardiovascular stents
PublicationThe degradation of polypyrrole (PPy) coated iron is studied in phosphate buffer saline solution at 37 °C by odd random phase multisine electrochemical impedance spectroscopy (ORP-EIS). PPy is electropolymerized with anti-inflammatory salicylates incorporated in the film, as a drug release system. The modelling of EIS over time provides the quantitative description of the corrosion behaviour of the material. Thus, the reliable...
-
Zastosowanie próby implant do oceny spawalności stali
PublicationPraca dotyczy oceny spawalności stali o podwyższonej i wysokiej wytrzymałości w aspekcie eksperymentalnego określania skłonności do tworzenia pęknięć zimnych. W artykule opisano metodykę określania wrażliwości na pękanie próbą implant. Przedstawiono również proponowane w literaturze i autorskie sposoby opracowywania i przedstawiania wyników badań rozpatrywaną metodą i ich interpretacji.
-
Trudności podczas modelowania próby implant w programie Ansys.
PublicationW artykule przedstawiono trudności związane ze stworzeniem modelu próby implant w programie Ansys. Określono również trudności związane z przypisaniem odpowiednim strefom połączenia spawanego własności mechanicznych.
-
Implant Dentistry
Journals -
The progress in technology of biodegradable polymers
e-Learning CoursesKurs obejmuje 15 godz. Wykładów (18-22.01. 2021)z zagadnień związanych z omówieniem różnych polimerów biodegradowalnych, ich syntezą i postąpami w otrzymywaniu, analizie, zastosowaniu.
-
IMPLANT USED IN HERNIA REPAIR UNDER PHYSIOLOGICAL MOVEMENTS OF HUMAN ABDOMEN
PublicationThe study deals with the mechanical behaviour of implant used in repair of abdominal hernia. The influence of orientation of the orthotropic implants in different areas of abdominal wall is studied.
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublicationThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
Interface diffusion between metallic nanoparticles and silicon substrate
Open Research DataInterface diffusion between metallic nanoparticles and silicon substrate was detected by EDX method. Metallic nanostructures were manufactured by thermal annealing of thin films. Gold and silver nanostructures were chosen for measurements. Samples were annealed for 15 and 60 minutes at 550 deg.
-
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublicationThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
-
Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair
PublicationEven though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...
-
The Hydrolysis of Slowly Biodegradable Substrate in Activated Sludge
PublicationIn a present work a novel procedure, based on the standard batch tests and pretreatment of wastewater sample with coagulation-flocculation method, was proposed to evaluate the effects of hydrolysis of slowly biodegradable substrate (Xs) on biological nutrient removal (BNR) processes in activated sludge systems. The study was conducted at two large BNR wastewater treatment plants (WWTPs) in northern Poland: "Wschod" in Gdansk and...
-
Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformation
Publicationrelation to the different range of typical deformations observed in different directions and zones of abdomen surface due to the patients’ life activities, has a significant influence on the extreme junction forces in the mesh–tissue connections and hence the repair persistence. The finite element model of the orthotropic implant was developed, and the junction forces in the connections of tissue and mesh were studied. The kinematical...
-
Mathematical study of a tissue-implant connection in a ventral herniarepair in a context of the system's parameters
PublicationW pracy przedstawiono problem operowania przepuklin brzusznych u ludzi. Zaproponowano jednowymiarowy model układu powieź-implant. Na podstawie analizy wrażliwości zidentyfikowano najważniejsze parametry problemu.