Filters
total: 18595
filtered: 1345
-
Catalog
- Publications 13790 available results
- Journals 118 available results
- Conferences 7 available results
- People 420 available results
- Inventions 62 available results
- Projects 9 available results
- Laboratories 8 available results
- Research Teams 28 available results
- Research Equipment 4 available results
- e-Learning Courses 1575 available results
- Events 348 available results
- Offers 2 available results
- Open Research Data 2224 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: FISHER’S TEST
-
VIbration monitoring in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K09A - full-run
Open Research DataVIbration monitoring in reciprocating siding friction tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30,...
-
VIbration monitoring in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K09 - pre-run
Open Research DataVIbration monitoring in reciprocating siding friction tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30,...
-
X-ray images of Baltic herring. Data analysis
Open Research DataBased on the developed methodology for the: (i) optimal method of catching, (ii) transporting and storing fish, (iii) measuring and (iv) analyzing X-rays images, the existing collection of X-ray images of Baltic herring, caught in October 2002 during the Swedish component of the Baltic International Acoustic Survey (BIAS) in the Baltic proper (ICES...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #24 - #25.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #24 (upper, rotating), #25 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #28 - #29.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #28 (upper, rotating), #29 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #30 - #31.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #30 (upper, rotating), #31 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #20 - #21.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #20 (upper, rotating), #21 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #22 - #23.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #22 (upper, rotating), #23 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #28 - #29.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #28 (upper, rotating), #29 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #26 - #27.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #26 (upper, rotating), #27 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K09 - full run
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Fatigue data of Cement Bitumen Treated Material Mixture C3E5.5 (over 28 days of curing at 20C, field cores)
Open Research DataDataset presents data of fatigue life determined for cold recycled mixture – cement bitumen treated material mixture with following binding agents: 3% cement and 5.5% emulsion (C3E5.5). Mixture was designed according to Polish requirements for the base course of pavement. Mixture contains 60% of RAP material. Specimen size: f=100 mm, h=48,4 - 70,9 mm.
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Evaluation of antimicrobial activity of porous composites based on chitosan/poly (vinyl alcohol)
Open Research DataThe dataset contains the results of microbiological tests of composite porous materials whose activity was assessed for their ability to reduce the number of Escherichia coli and Staphylococcus aureus strain, representing the Gram (-) and Gram (+) bacteria, respectively.
-
Measurements of power supply system properties of "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Open Research DataTests of the power supply system of "SpeedLine magnetic" ultra-fast industrial robot for IML labeling were carried out to analyze the effect of the active power filter (APF) parameters on the power quality. at the target duty cycle. Tests were performed with the target duty cycle. Linear synchronous motors with permanent magnets were used to drive...
-
Wear in reciprocating siding friction tests. Ball-on-flat contact. Sintered alumina ceramics (98%). Lubricant - PARAFFIN OIL. Specim. set K09 - pre-run (10s)
Open Research DataFriction and wear tests in ball-on-flat contact. Both specimens made of sintered alumina ceramics (98%) - self-mated contact.Linear reciprocating motion.Lubrication: PARAFFIN OIL. Sliding velocity (peak): 0.1 m/s. Load (normal force): 5N. Test rig: TPZ-1 Tribometer.Running time: progressive increments of 10, 15, 30, 60, 180 and 300s. (stored in separate...
-
Plasma models, contribution matrix for detector setup and generated projections for plasma emissivity reconstruction in fusion devices
Open Research DataThe original plasma models for fusion devices, together with the complementary detector setup in the form of a contribution matrix and generated projections. Samples are packed inside a Plasma Tomography Format (PTF) files which is a part of the Plasma Tomography in Fusion Devices Python package, and inside the general JSON format. The constructed dataset...
-
Investigation of plasmon resonance in a silver nanoparticles
Open Research DataSilver nanostructures were prepared on borosilicate glass (Corning 1737F) substrates. Thin Ag films (1–9 nm thickness) were deposited using a table-top dc magnetron sputtering coater (EM SCD 500, Leica) in pure Ar plasma (argon, Air Products 99.999%). The Ag target was of 99.99% purity, the rate of layer deposition was about 0.4 nm·s−1, and the incident...
-
Acoustic emission signals in concrete beams under 3-point bending (plain concrete, steel fibre reinforced concrete, steel bar reinforced concrete)
Open Research DataThe DataSet contains the results of the mechanical behaviour of concrete beams with dimensions 40 x 40 x 160 cm3under the 3-point bending. Two concrete mixes, both based on the same design, were produced in the test programme. Mixture #1 was the plain concrete (PC), consisting of cement CEM I 42.5R (380 kg/m3), water (165 kg/m3), aggregate 0/2 mm (648...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen AMA1-MIC3-ROP1
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA7
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-AMA1F
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-P35
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA9
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA6
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MIC1L
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA1
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MAG1L
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-LDH2
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MIC3
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-ROP1
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-AMA1
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA5
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA2
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Transmission measurements between two geometrically small Vivaldi antennas performed in non-anechoic propagation conditions
Open Research DataThe dataset contains unprocessed measurements of complex transmission (and reflection) characteristics obtained in non-anechoic regime for a geometrically small, broadband spline-parameterized Vivaldi structure. The measurement setup comprises two Vivaldi antennas with the same topology where one is used as a reference structure, and another one as...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Open Research DataThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
The electrochemical response to Au electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the Au electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration, with...
-
Fatigue data of Cement Bitumen Treated Material Mixture C3E5.5 (over 28 days of curing at 20C)
Open Research DataFatigue data of Cement Bitumen Treated Material Mixture C3E5.5 (over 28 days of curing at 20C)
-
Radiation pattern measurements of geometrically small antennas performed in non-anechoic environments
Open Research DataThe dataset contains unprocessed measurements of radiation pattern characteristics performed in non-anechoic regime for three geometrically small antenna structures: a spline-parameterized Vivaldi structure, a compact spline-based monopole, and a quasi-Yagi geometry with enhanced bandwidth. The responses have been obtained over broad frequency ranges...
-
Measurements of electrically small antenna radiation patterns in non-anechoic environments using TGM
Open Research DataThe dataset contains raw and processed measurements of radiation pattern characteristics performed in non-anechoic regime for four antenna structures: a spline-parameterized Vivaldi structure, a compact spline-based monopole, super-ultrawideband antenna, and a quasi-Yagi component. The responses have been obtained at the selected frequencies of interest...
-
Complex modulus of Cement Bitumen Treated Material Mixture C3E5.5 (over 28 days of curing at 20C)
Open Research DataDataset presents data of complex modulus determined for cold recycled mixture – cement bitumen treated material mixture with following binding agents: 3% cement and 5.5% emulsion (C3E5.5). Mixture was designed according to Polish requirements for the base course of pavement. Mixture contains 60% of RAP material. Specimen size: f=100 mm, h=130 mm. Specimen...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....