displaying 1000 best results Help
Search results for: deceleration capacity
-
Identification of plate dynamic parameters for structural health monitoring
PublicationPraca przedstawia technikę wyznaczania parametrów modalnych wykorzystywanych w diagnostyce konstrukcji. Modalna masa, sztywność, tłumienie i postacie drgań wyznaczone są dla prostokątnej stalowej płyty na podstawie badań eksperymentalnych. Teoretyczne parametry modalne otrzymaneo z modelu MES. Omówiony został wpływ dodatkowej masy na parametry modalne konstrukcji.This paper presents a technique for modal parameters estimation for...
-
STUDY OF ARRAY OF MEMS INERTIAL MEASUREMENT UNITS UNDER QUASI-STATIONARY AND DYNAMIC CONDITIONS
PublicationA measurement system includes all components in a chain of hardware and software that leads from a measured variable to processed data. In that context, the type and quality of the sensors or measuring devices are critical to any measurement system. MEMS/IMU sensors lag behind leading technologies in this respect, but the MEMS/IMU performance rapidly changes while is relatively inexpensive. For this reason, the paper proposes...
-
Three-dimensional Web Geographic Information System using web-based technologies
PublicationWeb-based Geographic Information Systems offer a way of delivering geographic information to devices with small computational power, such as smartphones. In recent years, the rapid development of the Web Graphics Library (WebGL) made it possible to create rich interactive applications running inside a web browser and displaying three-dimensional objects using hardware acceleration. This paper presents a three-dimensional Web-GIS...
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018858031]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018856901]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Fatty (change of) liver, not elsewhere classified - Female, 54 - Tissue image [4140730008826451]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Male, 1 - Tissue image [3300730069417631]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other diseases of liver - Female, 55 - Tissue image [9140730014135791]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018855201]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of amniotic fluid and membranes - Female, 43 - Tissue image [3070630010181361]
Open Research DataThis is the histopathological image of PLACENTA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018852601]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018851211]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Oesophagitis - Female, 55 - Tissue image [9140730014146031]
Open Research DataThis is the histopathological image of ESOPHAGUS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fatty (change of) liver, not elsewhere classified - Female, 54 - Tissue image [4140730008823631]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of amniotic fluid and membranes - Female, 43 - Tissue image [3070630010187701]
Open Research DataThis is the histopathological image of PLACENTA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018852411]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Fatty (change of) liver, not elsewhere classified - Female, 54 - Tissue image [4140730008828681]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018852861]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Male, 1 - Tissue image [3300730069415801]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Preterm labour with preterm delivery - Male, 0 - Tissue image [328073002562461]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of amniotic fluid and membranes - Female, 43 - Tissue image [307063001018721]
Open Research DataThis is the histopathological image of PLACENTA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [413073001886741]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018855841]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018859461]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of amniotic fluid and membranes - Female, 43 - Tissue image [3070630010188841]
Open Research DataThis is the histopathological image of PLACENTA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018857781]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [413073001885421]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Hepatic failure, unspecified - Male, 0 - Tissue image [7060729599329441]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of amniotic fluid and membranes - Female, 43 - Tissue image [3070630010188341]
Open Research DataThis is the histopathological image of PLACENTA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018855341]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Preterm labour with preterm delivery - Male, 0 - Tissue image [3280730025626661]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018859321]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018862991]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018857481]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018852521]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018851661]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Infiltrating duct carcinoma, NOS - Female, 60 - Tissue image [4130730018858791]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Other specified disorders of amniotic fluid and membranes - Female, 43 - Tissue image [3070630010186091]
Open Research DataThis is the histopathological image of PLACENTA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Open Research DataThis dataset contains SEM images of gold nanocubes (AuNC), which were deposited at the conductive Si wafer surface and dried. The deposition method, the solvent used and AuNC concentration have a significant influence on the homogeneous distribution and their agglomeration at the surface, further influencing the electrochemical characteristics of the...
-
Investigation of magnetic order in a new intermetallic compound Nd2PtGe3
PublicationIn the present study we report a successful synthesis of the new intermetallic compound Nd2PtGe3 by an arc-melting method. The powder X-ray diffraction analysis indicates that this compound crystallizes in an disordered variant of the AlB2-type structure (space group P6/mmm, no. 191) with lattice parameters a = 4.2455 Å and c = 4. 1933 Å. The compound exhibits a cluster-glass transition below Tf = 2.9 K, characterized through ac...
-
Numerical and experimental investigation of thermal convection near electric devices with vertical channels
PublicationThis paper presents the results of numerical and experimental investigation of thermal convection near heat emitting surfaces of an electric device. For the intensification of thermal convection, special vertical channels were formed near the heat emitting surfaces of the device. An experimental test has proved that there is an optimal length of the channels – thermal convection is the most intensive then. Air velocity vectors...
-
Discrete random variables in reliability calculations of a reticulated shell
PublicationImplementation of the Point Estimation Method (PEM) in the reliability analysis of a three-dimensional truss structure is presented in the paper. The influence of geometric and material random parameters on the truss load-carrying capacity was investigated. The analysis was performed for different combinations of basic variables. Symmetric and asymmetric cases of snow load were taken to assess the structural reliability. Sensitivity...
-
Control strategies and comparison of the Dynamic Voltage Restorer
PublicationThis paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...
-
ECONOMICAL AND SAFE METHOD OF GRANULAR MATERIAL STORAGE IN SILOS IN OFFSHORE PORT TERMINALS
PublicationThe article discusses issues related with storage of granular materials in silos made of corrugated sheets and reinforced with vertical ribs. Advantages and disadvantages of these structures are named, and typical technological solutions used by largest silo producers are presented. Moreover, basic assumptions of Eurocode 3 are discussed in the context of determining the buckling load capacity of a ribbed jacket. Alternative methods...
-
Speech Intelligibility Measurements in Auditorium
PublicationSpeech intelligibility was measured in Auditorium Novum on Technical University of Gdansk (seating capacity 408, volume 3300 m3). Articulation tests were conducted; STI and Early Decay Time EDT coefficients were measured. Negative noise contribution to speech intelligibility was taken into account. Subjective measurements and objective tests reveal high speech intelligibility at most seats in auditorium. Correlation was found between...
-
Experimental tests of steel double-type balcony connections
PublicationThe paper presents analysis and results of experimental tests of full scale prefabricated balcony sets with dimensions (width × length × height): 2.0 m × 2.78 m × 0.186 m (in slope to 0.17 m). The sets consists of reinforced concrete slabs (balcony and ceiling) connected with each other by double-type balcony connections. The paper analyses the impact of variable parameters on the load carry capacity of elements. Additionally...
-
QoS Resource Reservation Mechanisms for Switched Optical Networks
PublicationThe paper regards the problem of resource reservation mechanisms for Quality of Service support in switched optical networks. The authors propose modifications and extensions for resources reservation strategy algorithms with resources pools, link capacity threshold and adaptive advance reservation approach. They examine proposed solutions in Automatically Switched Optical Network with Generalized Multi-Protocol Label Switching...
-
Poly(hydroxybutyrate-co-hydroxyvalerate) as a biodegradable binder in a negative electrode material for lithium-ion batteries
PublicationIn this work, graphite-based negative electrode for lithium-ion battery consisting a novel and biodegradable binder poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) is compared with standard graphite electrode with polyvinylidene fluoride (PVDF) as a binder. The rate and cycling performance of lithium ion insertion/extraction of electrodes with PHBV in a half-cell configuration are evaluated. Moreover, on the basis of the electrochemical...
-
Study of displacements of a bridge abutment using FEM
PublicationSteel sheet piles are often used to support excavations for bridge foundations. When they are left in place in the permanent works, they have the potential to increase foundation bearing capacity and reduce displacements; but their presence is not usually taken into account in foundation design. In this article, the results of finite element analysis of a typical abutment foundation, with and without cover of sheet piles, are presented...
-
Integrated Control in High-Speed Networks Using Constrained Model Predictive Control
PublicationThis paper studies congestion control in high-speed communication networks using Model Predictive Control (MPC). Network traffic is assumed to consist of best-effort and priority traffic sources. An integrated controller consisting of two control parts is designed. The controller calculates the capacity for priority sources and the input rate of best-effort sources. MPC is desirable as it can take into account the constraints on...