Filters
total: 2584
-
Catalog
- Publications 1941 available results
- Journals 3 available results
- Publishing Houses 9 available results
- People 46 available results
- Inventions 27 available results
- Projects 12 available results
- Laboratories 1 available results
- Research Teams 2 available results
- Research Equipment 3 available results
- e-Learning Courses 124 available results
- Events 26 available results
- Open Research Data 390 available results
displaying 1000 best results Help
Search results for: WAŁY NAPEDOWE
-
Dermatofibrosarcoma, NOS - Male, 73 - Tissue image [5050730010508551]
Open Research DataThis is the histopathological image of CONNECTIVE, SUBCUTANEOUS AND OTHER SOFT TISSUES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Obliczenia wymuszeń drgań skrętnych dla czterosuwowych silników widlastych. Prace XX Ogólnopolskiej Konferencji Polioptymalizacja i Komputerowe Wspomaganie Projektowania.
PublicationW pracy przedstawiono dwie metody obliczeniowe wymuszeń dla czterosuwowych silników widlastych. Najczęściej dane są przez producentów silników oddzielnie wymuszenia gazowe oraz wymuszenia masowe pochodzące od sił bezwładności.Dane te podawane są dla jednego cylindra. Na ich podstawie oblicza się ciśnienie styczne, a następnie dokonuje się rozkładu tej funkcji w szereg Fouriera. Uzyskuje się w ten sposób amplitudy i fazy poszczególnych...
-
Chemical treatment of crystalline silicon solar cells as a main stage of pv modules recycling = Obróbka chemiczna krzemowych ogniw słonecznych jako najważniejszy etap w recyklingu modułów fotowoltaicznych
PublicationIn recent years, photovoltaic systems have gained worldwide recognition and popularity as a environmentally friendly way of solving energetic problems. However, a problem of utilizing worn out photovoltaic systems, amount of which will rapidly increase in the future, is yet to be solved. Establishing a technology of recycling and reusing obsolete photovoltaic panels is a necessity.Photovoltaic modules in crystalline silicon solar...
-
APPLICATION OF REDUNDANCY IN SHIP POWER PLANTS OF OFFSHORE VESSEL
PublicationPower and propulsion systems of offshore units must be of a very high level of reliability. The loss of ability to perform functions of their components causes generally to very high economic losses, which may be increased by unused the weather window resulting to postponing the planned offshore operations. To ensure carrying out so expensive offshore operations in the most reliable way, various types of redundancies are built-in...
-
Potential Application of Solar Energy Systems for Electrified Urban Transportation Systems
PublicationThe paper presents a novel approach toward the use of solar energy systems in public transportation. The concept of energy generation in PV systems for supplying a trolleybus transportation system is proposed for the city of Gdynia (Poland). The suggested way of energy production allows reducing the environmental harm impact of the municipal transportation system. Moreover, the proposed way of green energy use can be a more profitable...
-
Supporting study tours in the teaching of architectural heritage
PublicationStudy tours are a highly effective way to acquire knowledge. They improve students’ understanding of issues that otherwise may seem partly abstract to them. Presented in this article is the unique way in Poland in which support is given to the teaching of architectural heritage. It has been carried out continuously for almost 50 years in the Faculty of Architecture at Gdańsk University of Technology (FA-UT), Gdańsk, Poland, in...
-
Mirosław Włas dr inż.
PeopleWykształcenie : 1987-1991 – Liceum Ogólnokształcące im. Jana Bażyńskiego w Ostródzie – profil matematyczno-fizyczny 1991-1996 Politechnika Gdańska – studia na Wydziale Elektrycznym 1997-2002 Politechnika Gdańska – studia doktoranckie na Wydziale Elektrotechniki i Automatyki 1998- 1999 Politechnika Gdańska – kurs ekonomii na Wydziale Zarządzania i Ekonomii PG 1997-2000 – kurs j. angielskiego - Zespół Lektorów BEST – Gdańsk 2003...
-
Kamila Kokot-Kanikuła mgr
PeopleKamila Kokot-Kanikuła is a digital media senior librarian at Gdańsk University of Technology (GUT) Library. She works in Digital Archive and Multimedia Creation Department and her main areas of interests include early printed books, digital libraries, Open Access and Open Science. In the Pomeranian Digital Library (PDL) Project she is responsible for creating annual digital plans, transferring files on digital platform, and promoting...
-
Zastosowanie przetworników jonoczułych typu isfet w bezprzewodowych sieciach sensorowych
PublicationW pracy przedstawiono zasadę działania pH-metrycznych czujników ISFET, ich istotne układy pracy oraz wady i zalety w analizie elektrochemicznej w środowiskach wodnych i niewodnych. Określono wymagania dla przetworników pracujących w warunkach polowych, poza laboratorium. Przedstawiono technologię bezprzewodowych sieci sensorowych. Zaproponowano układ węzła sensorowego ze skompensowanym termicznie różnicowym przetwornikiem ISFET...
-
Ekonomiczna ocena i kryteria doboru metod odzysku ciepła.
PublicationPrzedstawiono strukturę przeciętnych kosztów funkcjonowania systemu wentylacyjnego. Ustalono, że głównym ich składnikiem są koszty energii, co uzasadnia zastosowanie urządzeń do odzysku ciepła. Zdefiniowano pojęcie sprawności odzysku ciepła i porównano ich wartości do omawianych metod. Przedstawiono wady i zalety poszczególnych metod oraz porównano koszty inwestycyjne i eksploatacyjne, co umożliwia projektantom optymalny wybór...
-
Modelowanie zjawisk zachodzących w strefie tworzywo-forma podczas procesu wtryskiwania.
PublicationPodczas wtrysku w warstwie tworzywa przy ściance formy występują zjawiska, które są źródłem wad powierzchni wypraski. Zjawisko to opisano, oraz zaprezentowano model zachowania się tworzywa w tej strefie, opierając się na symulacji komputerowej procesu wtrysku. Symulację wykonano na komputerach CI TASK przy wykorzystaniu programu FIDAP. Występujące wady powierzchni opisano w oparciu materiał fotograficzny i profilogramów powierzchni.
-
Adaptacyjna kompensacja zniekształceń napięcia wyjściowego falownika z modulacją szerokosci impulsów
PublicationW artykule przedstawiono nową metodę kompensacji zniekształceń napięcia wyjściowego falownika. Metody polega na automatycznym wyznaczaniu parametrów zaproponowanego modelu napięcia zniekształceń, bez konieczności przeprowadzania szeregu kłopotliwych pomiarów. Jakość kompensacji jest na bieżąco oceniana na podstawie wskaźnika zniekształceń harmonicznych prądu fazowego. Metoda zapewnia mały poziom zniekształceń liniowych i nieliniowych...
-
Konkurencja w dostawie regulacyjnych usług systemowych
PublicationW artykule przedstawiono analizę aktualnego sposobu pozyskania usług systemowych w zakresie mocy czynnej i rezerw operacyjnych. Wskazano na wady obecnych mechanizmów. Zarysowano kierunek przekształceń rynku regulacyjnych usług systemowych w celu lepszego funkcjonowania w otoczeniu innych segmentów rynku (w szczególności Rynku Bilansującego) oraz zwiększenia możliwości konkurencji pomiędzy dostawcami usług. Omówiono problemy decentralizacji...
-
Influence of control loop on torsional vibrations of rotating machinery.
PublicationRozpatrywano wpływ pętli regulacyjnej silnika diesla na dynamikę układu napędowego okrętowego. Porównano obliczenia numeryczne z badaniami eksperymentalnymi. Stwierdzono duży wpływ pętli regulacyjnej silnika diesla na dynamikę układu. W obliczeniach numerycznych skoncentrowano się na drganiach skrętnych układu napędowego okrętowego. Analizowano wpływ sztywności skrętnej sprzęgła elastycznego na amplitudy momentów skrętnych...
-
Wpływ załączonych dodatkowych odbiorników mocy na testowe wyniki analizy spalin samochodu osobowego.
PublicationW artykule przedstawiono opracowane wyniki testów spalin przy załączonych w czasie testu dodatkowych odbiornikach energii. Badania przeprowadzono w wytwórni samochodów osobowych. Przebadano jeden samochód, po przebiegu 30 tys. km specjalnie opracowanym testem, powtarzanym pięciokrotnie dla każdego załączonego odbiornika. Wykazano wyraźny związek dodatkowej mocy pobieranej z wału silnika ze zwiększeniem ilości składników toksycznych...
-
KONCEPCJA SYSTEMU OCENY STANU TECHNICZNEGO PRZEJAZDÓW TRAMWAJOWYCH
PublicationPrzejazdy tramwajowe stanowią kluczowy element infrastruktury transportu miejskiego. Ich stan techniczny wpływa zarówno na bezpieczeństwo użytkowników linii tramwajowych jak i dróg kołowych. W artykule przedstawiono koncepcję oceny stanu technicznego przejazdów bazującą na doświadczeniach z gdańskiej sieci tramwajowej. Podano jej kryteria, zestawiono występujące wady i uszkodzenia oraz dokonano takiej oceny wraz z analizą przyczynowo...
-
Prognozowanie upadłości przedsiębiorstw - fakty i mity
PublicationW rozdziale ukazano mity oraz fakty, jakie związane są z wykorzystywaniem modeli prognozowania zagrożenia przedsiębiorstw upadłością. Ponadto na tej podstawie zaprezentowano ich zalety, wady oraz ograniczenia im towarzyszące. Dywagacje na ten temat zostały poprzedzone rysem historycznym, który pełni rolę wprowadzenia do dyskusji. Natomiast końcowe wnioski dotyczą przyszłości i pożądanych kierunków zmian w tym obszarze badawczym.
-
Konstrukcje i zastosowania współczesnych silników Stirlinga
PublicationW pracy omówione zostały przyczyny rosnącego zainteresowania komercyjnego wykorzystania silników Stirlinga. Scharakteryzowane zostały podstawowe typy silników Stirlinga ze względu na układ przestrzeni roboczej i cylindrów. W pracy przedstawione zostały przykłady współczesnych konstrukcji tych silników, dokonano również analizy aktualnych i planowanych zastosowań silników Stirlinga. Omówiono podstawowe zalety i wady wykorzystania...
-
Tax preferences in CIT in numbers 2009-2015
Open Research DataThese data contain information prepared by the Ministry of Finance on the value of tax preferences by areas of support in Corporate Income Tax (CIT) between 2009-2015.
-
Electrical responses of Graphene-Silicon Schottky diodes toward nitrogen dioxide and tetrahydrofuran under irradiation
Open Research DataGraphene-Silicon Schottky junctions were utilized as gas sensors toward inorganic (nitrogen dioxide) and organic (tetrahydrofuran) gas qualitative and quantitative detection. The electrical responses of the sensors were collected in the form of current-voltage characteristics and measurements of current in time domain for a selected voltage bias. The...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...