CTD Gdańsk Deep_2001_2005
Dane BadawczeDataset includes measurements of conductivity (mS cm-1), temperature (°C), sound speed (m s-1) and salinity (PSU) made with the probe Falmouth Scientific Inc. The research was carried out in 2001 (at the turn of May and June), 2003 (beginning of May), 2005 (end of April) and in 2002 and 2004 (at the turn of September and October). In 2002, only temperature...
-
SEM and Raman studies B:CNWs and BDD electrode used for electrochemical paraquat determination
Dane BadawczeThe dataset contains the scanning electron micrographs (SEM) and Raman spectra of B:CNWs and BDD samples deposited by MW-PECVD. SEM was used to characterise the morphology of BDD and B:CNW. In contrast, RAMAN was used to reveal the main differences in the crystalline structure of BDD and B:CNWs.
-
Hemocompatibility of nanocrystalline diamond layers
Dane BadawczeThe biocompatibility of the diamond films were investigated with whole human blood samples. Blood used in this study was drawn from 10 healthy human patients of different age, sex, and blood group. A 2 ml samples were collected into standard tubes with EDTA anticoagulation agent. Blood was used within 6 hours from the collection time. A reference blood...
-
Scanning electron microscopy (SEM) images of the boron-dopied diamond surfaces
Dane BadawczeThe dataset contains the scanning electron micrographs (SEM), revealing the surface morphology of diamond electrodes on silicon substrates. The diamond surface is characterized by ultra-crystalline diamonds obtained by CVD synthesis.
-
CFD analysis of a flow in commutation window in PWK pump
Dane BadawczeThe included data is a result of CFD analysis of a flow in a commutation window in PWK pump. The results were obtained for different pressures, viscosities and geometrical parameters of the gap. All the rows and columns have descriptions similar as in PhD Thesis: "Kompensacja skoków ciśnienia w pompie tłoczkowej o zmiennej wydajności z rozrządem krzywkowym",...
-
Raman data of deuterium and hydrogen grown boron-doped diamond
Dane BadawczeRaman spectra were recorded at room temperature using a micro-Raman spectrometer (Invia, Renishaw) equipped with an edge filter with different excitation wavelengths and lasers: UV λ = 325 nm (HeCd), blue λ = 488 nm (Ar+), green λ = 514 nm (Ar+), and IR λ = 785 nm (IR diode) and 50× microscope objective. To avoid sample heating, the radiation power...
-
XPS data of deuterium and hydrogen grown boron-doped diamond
Dane BadawczeThe high-resolution C1s X-ray absorption spectra of BDD@H and BDD@D samples were measured using the facilities of the HE-SGM beamline (HE-SGM) at the BESSY II synchrotron radiation source of Helmholtz–Zentrum Berlin (HZB).[90] The measurements were carried out under ultra-high vacuum conditions: P ≈ 2×10−9 Torr at T = 300 K. The NEXAFS spectra were...
-
SEM micrographs of boron-doped nanocrystalline diamond-carbon nanospikes
Dane BadawczeThis dataset contains the Scanning Electron Microscopy (SEM) micrographs taken for rich boron-doped carbon crystalline nanospikes/nanograss structures, at different magnifications, encoded in the labels of the images. The micrographs were made using Hitachi S-3400N SEM microscope in secondary electron mode under 20 kV accelerating voltage. No additional...
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst LNCaP cancer cells
Dane BadawczeTis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst LNCaP cancer cells. FA (folic acid) with cyclodextrin (CD) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst H460 cancer cells
Dane BadawczeThis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst H460 cancer cells. FA (folic acid) with cyclodextrin (CD) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Scanning electron microscopy (SEM) images of the boron-dopied diamond surfaces
Dane BadawczeThe dataset contains the scanning electron micrographs (SEM), revealing the surface morphology of diamond electrodes on different substrates. The diamond surface is characterized by an aggregation of crystals that do not form a continuous layer.
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst MRC-5 normal cells
Dane BadawczeTis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst MRC-5 normal cells. FA (folic acid) with cyclodextrin (CD) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst Du-145 cancer cells
Dane BadawczeTis study presents absorbance values of formazan product (converted from MTT) which corresponds the cytotoxicity of C-2028, QDgreen, QDred, QDgreen-CD-FA, QDred-CD-FA, QDgreen-CD-FA-C-2028 and QDred-CD-FA-C-2028 aginst LNCaP cancer cells. FA (folic acid) with cyclodextrin (CD) was used as a linker between quantum dots (QDs) and compound (C-2028).
-
Electrochemical studies of Boron-Doped Diamond enriched Laser Induced Graphene structures
Dane BadawczeThis dataset contains electrochemical studies aimed to evaluate the capability of the utilization of laser-induced graphene (LIG) with incorporated boron-doped diamond nanowall (BDNW) hybrid nanostructures for microsupercapacitors. Selected results from this dataset were published in Advanced Functional Materials journal: https://doi.org/10.1002/adfm.202206097
-
Topography studies of screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Dane BadawczeThis dataset contains topography examination of SPCE containing boron-doped diamond BDD foils done with scanning electron microscope. Different points mark different electrode spots: A) working electrode, B) reference electrode, C) counter electrode, D) pads.
-
Electrochemical studies for screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Dane BadawczeThis dataset contains electrochemical examination of SPCE paste and SPCE containing boron-doped diamond BDD foils. The studies include kinetics analyses with cyclic voltammetry and electrochemical impedance spectroscopy with different redox probes: hexacyanoferrate(III) and Hexaammineruthenium(III) and potentiostatic open circuit potential at different...
-
Complete input data to CFD 3D model of combustion in the large marine 4-stroke engine
Dane BadawczeInput data to CFD and 3D model of combustion process for large marine 4-stroke diesel engine.
-
Chemical and structural studies of screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Dane BadawczeThis dataset contains chemical analyses and structural studies by XPS and Raman spectroscopy, carried out for SPCE containing boron-doped diamond BDD foils done with scanning electron microscope. Different points for XPS analysis mark different electrode spots: A) working electrode, B) reference electrode, C) counter electrode, D) pads.
-
Sound signals generated during lapping of technical ceramics using electroplated tools with diamond grains
Dane BadawczeData contains the recordings of sound generated during single-sided lapping with the use of electroplated diamond tools. This relationship was examined with the use of spectral analysis of the sound signal in the frequency domain with a focus on the Ra parameter of the surface roughness. The estimated sound coefficient increased as the surface roughness...
-
The impact of QDgreen, QDgreen−β−CD−FA, β−CD, C−2028, β−CD(C−2028), QDgreen−C−2028, and QDgreen−β−CD(C−2028)−FA nanoconjugates on lysosomal content in the cancer (H460, Du-145, LNCaP) and normal (MRC-5, PNT1A) cells
Dane BadawczeThe impact of QDgreen, QDgreen−β−CD−FA, β−CD, C−2028, β−CD(C−2028), QDgreen−C−2028, and QDgreen−β−CD(C−2028)−FA nanoconjugates on lysosomal content in the cancer (H460, Du-145, LNCaP) and normal (MRC-5, PNT1A) cells was performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). To explore the influence...
-
Electrochemical impedance spectra and CV curves of V2O5 nanocrystals
Dane BadawczeThe DataSet contains the EIS spectra for coin-cells and CV curves with the V2O5 nanocrystals obtained by the sol-gel method. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were measured using the AUTOLAB 302N potentiostat-galvanostat under Nova software. The EIS measurements were recorded in the frequency range 100 kHz to 10 mHz...
-
Electrochemical impedance spectra and CV curves of V2O5 nanorods
Dane BadawczeThe DataSet contains the EIS spectra for coin-cells and CV curves with the V2O5 nanorods obtained by the sol-gel method. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were measured using the AUTOLAB 302N potentiostat-galvanostat under Nova software. The EIS measurements were recorded in the frequency range 100 kHz to 10 mHz for...
-
Anomalous anisotropy of deuterium-grown boron-doped diamond and the role of boron-tetramers in the Mott-Insulator transition
Dane BadawczeWe show anisotropy in the superconductivity for boron-doped diamond thin films prepared with Microwave Plasma Assisted Chemical Vapor Deposition using deuterium-rich plasma. This anomalous phase transition is linked with the emergence of boson quantum entanglement states behaving as a bosonic insulating state. Here, we show that the superconducting...
-
Scanning electron microscopy (SEM) images of boron-doped diamond thin films at poly(lactic acid)
Dane BadawczeThe dataset contains the photos obtained by scanning electron microscope(SEM), revealing the surface morphology and cross-section of boron-doped diamond electrodes on commercially available graphene-doped polylactide acid. The boron doping level expressed as the [B]/[C] ratio in the gas phase for these studies was 500 and 10,000 ppm. The top views of...
-
The scanning electron microscopy (SEM) studies of heavy boron-doped diamond oxidation under high-temperature
Dane BadawczeThe dataset contains the results of scanning electron microscopy (SEM) images of heavy boron-doped diamond (BDD) electrodes subjected to high-temperature oxidation in a furnace at 600 Celsius. The micrographs reveal the material decomposition of BDD grains due to high temperature.
-
SEM micrographs of diamond-phase (sp3-C) rich boron-doped carbon nanowalls (sp2-C)
Dane BadawczeThis dataset contains the Scanning Electron Microscopy (SEM) micrographs taken for rich boron-doped carbon nanowalls structures, with different boron addition during the synthesis process and different CVD synthesis duration. The [B]/[C] ratios in the plasma were set to 0k, 1.2k, 2k and 5k ppm. The time of growth was ranging between 4 and 9 hours. This...
-
The electrochemical studies of thin boron-doped diamond films deposited at conductive poly(lactic acid) 3D prints
Dane BadawczeThe dataset contains the electrochemical characteristics of the electrodes composed of thin boron-doped diamond films coated on commercially available graphene-doped polylactide acid. The boron doping level expressed as the [B]/[C] ratio in the gas phase for these studies was 500 and 10,000 ppm.
-
The scanning spreading resistance microscopy (SSRM) studies of heavy boron-doped diamond oxidation under high-temperature
Dane BadawczeThe dataset contains the results of scanning spreading resistance microscopy (SSRM) of heavy boron-doped diamond (BDD) electrodes subjected to high-temperature oxidation in a furnace at 600 Celsius. The micrographs reveal the local change of electric properties at certainly crystallographic orientations of BDD grains and at the grain boundaries due...
-
Performance of Haemophilus influenzae impedimetric biosensors based on screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy studies of SPCE electrodes containing boron-doped diamond BDD foils and functionalized towards detection of Protein D and Haemophilus influenzae.
-
CV (cyclic voltammetry) curves of the CPMD sample at different scan rates
Dane BadawczeThese data contain CV curves of CPMD obtained at a scan rate from 1 mV s−1 to 20 mV s−1. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication.
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer LNCaP cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer LNCaP cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer H460 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer H460 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal PNT1A cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal PNT1A cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer Du-145 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer Du-145 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal MRC-5 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal MRC-5 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The BDD electrodes wettability modification by anodic polarization treatment
Dane BadawczeThe dataset contains the raw images, photographs obtained for the contact angle measurement at the surface of the boron-doped diamond (BDD) electrode. The measurements were carried out on after potentiodynamic polarization procedure, at various anodic polarization scan range (no polarization - HTBDD; 1.0 V; 1.4 V; 1.9 V; 2.5 V vs Ag|AgCl, scan rate...
-
Distance measurement by the low coherent interferometer
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Technology and democracy: the who and how in decision-making. The cases of Estonia and Catalonia. METADATA
Dane BadawczeThe analysis of the Estonian data comes mainly from studies conducted to analyse the cost-efficiency of the Estonian online voting model (Krimmer; Duenas-Cid; Krivonosova, 2021), as well as from the contagion effect that ensued in other parts of the Estonian administration after the voting system was developed (Krimmer; Duenas-Cid,2019). In both cases,...
-
Technology and democracy: the who and how in decision-making. The cases of Estonia and Catalonia. METADATA 1
Dane BadawczeThe analysis of the Estonian data comes mainly from studies conducted to analyse the cost-efficiency of the Estonian online voting model (Krimmer; Duenas-Cid; Krivonosova, 2021), as well as from the contagion effect that ensued in other parts of the Estonian administration after the voting system was developed (Krimmer; Duenas-Cid,2019). In both cases,...
-
Determining the optimal filling of the surface with a linker with Universal Force Field and Reax Force Field
Dane BadawczeThe DataSet contains the atomic slabs of diamond surfaces with ATP molecules in water. The calculated data includes different sized surfaces from 90 Angstrom^2 to 691 Angstrom^2. Structures were relaxed using the Reax Force Field method with the Limited Memory Broyden–Fletcher–Goldfarb–Shanno algorithm. Structures were calculated with a convergence...
-
Laser microscope profilometry of (Ce0.80Gd0.20)O1.90 after ∼3 μm surface finish
Dane BadawczeThe dataset consists of a surface image and topography obtained using a Keyence VK-X1000 confocal laser microscope for (Ce0.80Gd0.20)O1.90 substrate (CGO-20). Imaging was performed to determine surface roughness. The Keyence VK-X1000 uses a 404 nm laser to map and measure the surface of samples via confocal scanning or a wide-field variable focus. The...
-
The mechanism of internalization study of QDgreen−CD−FA−C−2028 conjugate at IC80 value to cancer (H460, Du-145, and LNCaP) and normal (MRC-5 and PNT1A) cells
Dane BadawczeThe influence of different endocytosis inhibitors on the internalization of QDgreen−CD−FA−C−2028 conjugate at IC80 value in cancer (H460, Du-145, and LNCaP) and normal (MRC-5 and PNT1A) cells. First, the cells were preincubated with: drug-free medium (no inhibitor), at 4 °C, 5 µM Cytochalasin D, 30 µM Amiloride, 80 µM Dynasore, 25 µM Pitstop 2 and 1.5...
-
The electrochemical response to BDD electrode functionalization with CD147 receptor
Dane BadawczeThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with CD147 receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to BDD electrode functionalization with ACE2 receptor
Dane BadawczeThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with ACE2 receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
The electrochemical response to BDD electrode functionalization with IgG2B receptor
Dane BadawczeThis dataset contains the results of the electrochemical impedance spectroscopy (EIS) measurements of the boron-doped diamond (BDD) electrode functionalization with IgG2B receptor. The functionalized electrode was then used for the electrochemical detection of the SARS-CoV-2 virus S1 protein.
-
High resolution XPS analysis of BDD electrode functionalization steps towards SARS-CoV-2 detection
Dane BadawczeThis dataset contains the results of the high-resolution XPS analyses of a set of boron-doped diamond (BDD) electrodes after consecutive functionalization steps toward anchoring of a receptor capable of SARS-CoV-2 virus detection. The analysis was carried out in the binding energy range of C1s, N1s, O1s, Ni2p3/2. The measurements were carried out on...
-
Results after grinding C45 steel
Dane BadawczeThe database contains results from nanoindenter, scanning microscope and also X-ray diffractometer. To determine the residual stresses and the size of the crystallites in the ferrite grains in the grinded surface layer, the Williamson Hall analysis of the X-ray diffraction patterns was performed. XRD diffraction patterns were also used to perform a...
-
Evaluation of the electrochemical performance of CPMD in ZICs with 3M ZnSO4 electrolyte
Dane BadawczeThese data contain the results of the electrochemical performance measurements of CPMD in ZICs with 3M ZnSO4 electrolyte, incl. CGD (galvanostatic charge-discharge ) curve and cycling stability of CPMD. Sample abbreviations (CPMD) are in agreement with the markings used in the linked publication.
-
Determination of the MIC (minimum inhibitory concentration) of new bisacridines IKE16-19, IKE21 and IE10 against C. glabrata clinical strains
Dane BadawczeThe datasets contain the results of determining the MIC value (minimum inhibitory concentration) of new bisacridines IKE16-19, IKE21 and IE10 against Candida glabrata clinical strains CZD 310, 373, 377, 513 and collection strain DSM 11226 by the modified M27-A3 specified by the CLSI.