Filtry
wszystkich: 2837
wybranych: 429
-
Katalog
- Publikacje 2373 wyników po odfiltrowaniu
- Czasopisma 6 wyników po odfiltrowaniu
- Konferencje 2 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 14 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Kursy Online 11 wyników po odfiltrowaniu
- Dane Badawcze 429 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: FREQUENCY-DEPENDENT COUPLING
-
Dual role of oxygen-related defects in the luminescence kinetics of AlNMn2+
Dane BadawczeThis dataset presents the impact of temperature and pressure on AlN:Mn2+ luminescence kinetics. Unusual behavior of Mn2+ optical properties during UV excitation is observed, where a strong afterglow luminescence of Mn2+ occurs even at low temperatures. When the temperature increases, the contribution of the afterglow luminescence is further enhanced,...
-
Optimization of the femtosecond laser impulse for excitation and the spin-orbit-mediated dissociation in the NaRb molecule
Dane BadawczeHigh accuracy ab initio potential energy curves (1tSigma+, 2sSigma+, 1tPi), electronic transition dipole moment function (1tSigma+ - 1tPi), and spin-orbit coupling (2sSigma+ - 1tPi) have been calculated for the NaRb molecule. The time-dependent excitation and dissociation processes in the polar alkali diatomic NaRb molecule and the quantum properties...
-
Autocorrelation function for the chosen effective potential of the diatomic silver anion
Dane BadawczeThe process of a two-channel decay of the diatomic silver anion (Ag2-), namely the spontaneous electron ejection giving Ag2 + e- and the dissociation leading to Ag- + Ag is theoretically studied. The ground state potential energy curves (PECs) of the neutral silver dimer and anionic silver diatomic molecule are calculated using the single reference...
-
Opposite pressure impact on electron-phonon coupling in Eu2+ and Ce3+ doped AlN
Dane BadawczeThis data analyzes the influence of pressure on electron–lattice interactions in the 5d excited states of Ce3+ and Eu2+ in the AlN host based on pressure-dependent photoluminescence and photoluminescence excitation spectra. High-pressure measurements on AlN samples doped with Eu2+ and Ce3+ ions reveal that the Stokes shift increases with pressure for...
-
SEM micrographs of V2O5 thin film morphology dependent on substrate types
Dane BadawczeThe DataSet contains the scanning electron microscopy (SEM) micrographs of V2O5 thin film morphology dependent on substrate types. The as-prepared thin films were deposited on alumina, zirconium, zirconium oxide and metallic vanadium substrate, then was annealing under an oxidizing atmosphere at 600C for 10h. The results show that the morphology of...
-
Spin-Orbit Coupling Matrix Elements in the KRb Molecule
Dane BadawczeThe allowed 190 spin-orbit coupling (SOC) matrix elements have been calculated for the singlet (s) and triplet (t) Sigma+ (S+), Pi (P), and Delta (D) electronic states of the KRb molecule. These SOCs are needed for investigations of areas connected with classical spectroscopy, deperturbation analysis of the observed spectra, atom-molecule and molecule-molecule...
-
Non-adiabatic coupling elements between the diatomic silver anion and neutral silver dimer plus continuum electron
Dane BadawczeThe process of a two-channel decay of the diatomic silver anion (Ag2-), namely the spontaneous electron ejection giving Ag2 + e- and the dissociation leading to Ag- + Ag is theoretically studied. The ground state potential energy curves (PECs) of the neutral silver dimer and anionic silver diatomic molecule are calculated using the single reference...
-
XRD patterns of V2O5 thin film morphology dependent on substrate types
Dane BadawczeThe DataSet contains the XRD patterns of the V2O5 thin film structure dependent on substrate types. The as-prepared thin films were deposited on alumina, zirconium, zirconium oxide and metallic vanadium substrate, then was annealing under an oxidizing atmosphere at 600C for 10h.
-
Low frequency nois of supecapacitor
Dane BadawczeDataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor...
-
Low frequency nois of supecapacitor
Dane BadawczeDataset contains noise measurement results on prototype electrochemical double layer capacitor. The measurement procedure is described in https://dx.doi.org/10.1515/mms-2017-0059.
-
The low-frequency magnetic field emissions on-board of the vessel
Dane BadawczeThe data represents measurement results performed on board of the vessel. The acquired time-waveforms, corresponding to the instantaneous values of the magnetic field (MF) induction were acquired near the cable supplying the bow thruster motor. Data recording of the magnetic field density (MFD) emissions was carried out with a/d converters of the data...
-
The dataset of coupling coefficients for rotating receiver of multicoil dynamic wireless power transfer system
Dane BadawczeThe provided dataset is part of the simulation results shown in related journal paper "Optimal Rotating Receiver Angles Estimation for Multicoil Dynamic Wireless Power Transfer".
-
Audible noise in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
Experimental investigation of the weight averaging of pulse frequency modulated sensor output signal
Dane BadawczeThe research aims to practically verify the results of theoretical analysis and simulations of the efficiency of weight averaging of pulse frequency modulated signal. For this purpose, a suitable test stand was built, and the control software in the LabVIEW environment was prepared. Then, a series of experiments were carried out to process and analyze...
-
Simulation of the weight averaging of pulse frequency modulated sensor output signal
Dane BadawczeThe aim of the research is investigation of the efficiency of weight averaging of pulse frequency modulated signal. It was shown that from the point of view of the reduction of the sampling error the best are polynomial weighing functions, for which the maximum of this component error decreases proportionally to the appropriate power of the number of...
-
Frequency of neoplasia in the baltic clam Limecola balthica from the Gulf of Gdańsk between 1999-2002
Dane BadawczeThe presented dataset contains data describing the frequency of neoplasia in one of the most common bivalve species inhabiting the Baltic Sea, the baltic clam Limecola balthica. The frequency of neoplasia was assessed at various locations of the Gulf of Gdańsk between years 1999 - 2002. The dataset contains information describing the sampling areas...
-
Time frequency representation of Doppler boold flow recordings
Dane BadawczeVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
The radiated immunity test of an astable multivibrator in the frequency range from 100 MHz to 300 MHz
Dane BadawczeThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 100 MHz to 300 MHz were...
-
The AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
The power spectral density of audible noise and electric disturbances in ship’s electrical drive systems with frequency converters
Dane BadawczeThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
Surface-dependent biological potential of spherical silver nanoparticles
Dane BadawczeThe growing interest in silver nanoparticles (AgNPs) is largely driven by their significant antimicrobial potential. As carriers of reactive silver ions on a nanoscale, AgNPs are considered excellent candidates for specific antibacterial strategies. Numerous scientific studies have highlighted that AgNPs are broad-spectrum antimicrobials, with their...
-
Measurements of the fundamental harmonic frequency of voltages on main bars in a ship power station
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the fundamental...
-
The time-varying low-frequency magnetic-field emitted from the ship’s inverter-fed induction motor
Dane BadawczeThe dataset contains the magnetic field measurement results that are part of a comprehensive study on the assessment of the magnetic field emissions onboard of the research-training vessel. The measurements were carried out, nearby the bow thruster motor fed from the inverter, during maneuvering and the sea voyage. The bow thruster is assembled in the...
-
Frequency Response Functions for Sandvik CoroBore 825 XL boring tool, 733 mm
Dane BadawczeFrequency Response Functions (FRF) obtained for Sandvik CoroBore® 825 XL mounted at WHN 13-15 TOS VARNSDORF CNC machine at the minimum extension of the spindle adaptor. Tool set to bore a hole with a diameter 733mm
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer LNCaP cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer LNCaP cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer H460 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer H460 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal PNT1A cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal PNT1A cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
Oxygen partial pressure and temperature dependence of low frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Dane BadawczeThis dataset contains values of low frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of middle frequency capacitance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Dane BadawczeThis dataset contains values of middle frequency capacitance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of low frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Dane BadawczeThis dataset contains values of low frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
Oxygen partial pressure and temperature dependence of middle frequency resistance of symmetrical porous Sr0.86Ti0.65Fe0.35O3 electrode on CGO substrate
Dane BadawczeThis dataset contains values of middle frequency resistance at different temperatures (800 °C, 750 °C, 700 °C, 650 °C and 600 °C) and oxygen partial pressures (20%, 10%, 5%, 1%, 0.1% and 0.01% pO2) of symmetrical Sr0.86Ti0.65Fe0.35O3 electrode sintered at 1000 °C. This values were obtained by fitting each measured impedance spectra by electrical equivalent...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer Du-145 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to cancer Du-145 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
The time-dependent cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal MRC-5 cells
Dane BadawczeThe time-dependent (1, 24, 48, and 72 h) cellular uptake of C−2028, CD−C−2028, QDgreen−C−2028, and QDgreen−CD−FA−C−2028 conjugates at IC80 value to normal MRC-5 cells performed by Confocal Laser Scanning Microscopy (63× magnification; ZEISS LSM T-PMT, Magdeburg, Germany). Based on the fluorescence properties of these compounds, green and orange fluorescence...
-
Oxygen partial pressure and temperature dependence of R-CPE2 frequency of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Dane BadawczeThis dataset contains values of equivalent circuit element R-CPE2 frequency at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Oxygen partial pressure and temperature dependence of R-CPE1 frequency of symmetrical porous SrTi0.30Fe0.70O3 electrode on CGO substrate
Dane BadawczeThis dataset contains values of equivalent circuit element R-CPE1 frequency at different temperatures (800 °C, 700 °C, 600 °C and 500 °C) and oxygen partial pressures (100%, 80%, 50% 30%, 20%, 15%, 10%, 5%, 2.5%, 1%, and 0.3% pO2) of symmetrical SrTi0.30Fe0.70O3 electrode sintered at 800 °C. This values were obtained by fitting each measured impedance...
-
Magnetic field maps of an astable multivibrator in frequency range from 100 kHz to 50 MHz
Dane BadawczeThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
Electric field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz
Dane BadawczeThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain electric field maps created on based measurements...
-
Nonlinear impedance as a function of frequency for Bi2VO5.5 ceramic of thickness 2.88 mm was measured at high temperature range with impedance spectroscopy method
Dane BadawczeThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.88 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of temperature and frequency for Bi2VO5.5 ceramic of thickness 2.52 mm was measured at different A.C. voltage with impedance spectroscopy method
Dane BadawczeThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm was measured by impedance spectroscopy method.
-
Magnetic field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz – spatial detection
Dane BadawczeThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
Results and models for Novel high frequency components with non-conventional shape employing smooth geometry deformation of 3D solid with FFD
Dane BadawczeThe project aims to investigate the possibility of developing and manufacturing novel high frequency devices having non-standard geometries, allowing for improved electromagnetic performance over what is achievable with currently available design tools. The non-conventional geometry will be obtained by employing the free-form shape deformation technique...
-
Magnetic field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz – selective detection
Dane BadawczeThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
SEM micrographs of morphology evolution of VO2 and V2O3 thin films obtained at 1000°C dependent on film thickness
Dane BadawczeThe DataSet contains the scanning electron microscopy (SEM) micrographs of VO2 and V2O3 thin films obtained by the sol-gel method. The information about sol synthesis is described in the Journal of Nanomaterials. The thin films with different thicknesses (2-3 AsP layers) were deposited on a silicon substrate and were annealing at 1000°C under an argon...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h. High frequency burst recording.
Dane BadawczeWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. High frequency burst recording.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21,...
-
Skin Conductance Level (SCL) data collected during mental training of group of 30 athletes
Dane BadawczeThe dataset contain raw Skin Conductance Level (SCL) data, collected at a frequency of 40 Hz and expressed in units of microsiemens (μS), during mental training of group of 30 athletes, under the project "Psychophysiology of guided and self-produced imagery in sport".
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...