Filtry
wszystkich: 737
wybranych: 682
Wyniki wyszukiwania dla: LOW VOLTAGE
-
Low voltage photovoltaic power system
PublikacjaThe use of photovoltaics is growing rapidly in the industry as well as households. Therefore, educating the public will help them understand solar cell technology, which is becoming more common in everyday life. This paper proposes a demonstrational set-up of photovoltaic panel for the purpose of science education. It was used in numerous outreach activities such as science fairs. Moreover, it proved to be a great tool for education...
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublikacjaThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Multipulse inverter structures with low voltage distortion
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Quality assessment of low voltage surge arresters
PublikacjaUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
The Phenomena of Bursts by Opening Low-Voltage Relay
Publikacja -
A High-Efficient Low-Voltage Rectifier for CMOS Technology
PublikacjaA new configuration of rectifier suiting CMOS technology is presented. The rectifier consists of only two nchannel MOS transistors, two capacitors and two resistors; for this reason it is very favourable in manufacturing in CMOS technology. With these features the rectifier is easy to design and cheap in production. Despite its simplicity, the rectifier has relatively good characteristics, the voltage and power efficiency, and...
-
Improving voltage levels in low-voltage networks with distributed generation – case study
PublikacjaThe use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublikacjaRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublikacjaLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Concept of Wireless Low-Voltage DC Socket for the Residential House Application
PublikacjaThe proposed research is devoted to the comprehensive theoretical and experimental study of the concept of the wireless low power dc socket for residential applications. The main goal of this work is to provide safe dc source for residential customers at power level which is enough in order to supply all typical appliances without power factor correctors. Such types of devices can be already connected to the dc grid and decoupled...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublikacjaAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublikacjaW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublikacjaW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublikacjaThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Protection against electric shock in electrical installations with low voltage generating sets
PublikacjaW referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublikacjaCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Random components influence on the values characterising periodic disturbances in low voltage supply lines.
PublikacjaAnalizowano wpływ składowych losowych na wielkości charakteryzujących zaburzenia okresowe w napięciu zasilania na przykładzie współczynnika zawartości harmonicznych (THD). Zaprezentowano sposób wyznaczania niepewności pomiaru współczynnika THD, uwzględniający występowanie korelacji pomiędzy składową podstawową i kolejnymi harmonicznymi napięcia sieci a także między poszczególnymi harmonicznymi. Przedstawiono analizę wyników z pomiarów...
-
Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response
PublikacjaIn this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Efficient Analysis of Noise Induced in Low-Voltage Installations Placed Inside Buildings with Lightning Protection Systems
PublikacjaThis paper describes an efficient approach to the broadband analysis of lightning protection systems (LPSs) using the method of moments (MoM) implemented in the frequency domain. The adaptive frequency sampling (AFS) algorithm, based on a rational interpolation of the relevant observable (e.g., voltage, current, electric or magnetic field) which describes the properties of the LPS, is employed to reduce the number of samples computed...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublikacjaThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
Publikacja -
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublikacjaThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Low harmonic multipulse voltage converters using coupled reactors
PublikacjaThis paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...
-
Dynamic current-voltage characteristics of dielectrics with extremely low heat conductivity
PublikacjaZaprezentowano teoretyczny opis metody dynamicznych charakterystyk prądowo-napięciowych w przypadku znacznego gradientu temperatury w ciałach stałych o przewodności jonowej. Otrzymano rozwiązania równania transportu oraz równania charakterystyk, odnoszące się do ruchu cienkiej warstwy nośników ostałej grubości oraz warstwy rozszerzającej się. Podano także przybliżone wyrażenia opisujące czas przelotu nośników. Wyniki zweryfikowano...
-
Output-capacitorless low-dropout regulator using a cascoded flipped voltage follower
PublikacjaPrzedstawiono udoskonaloną konfigurację wtórnika napięciowego w odwróconej konfiguracji oraz jej zastosowanie w regulatorze o małym spadku napięcia. W pracy przedstawiono teoretyczną analizę podstawowych parametrów wtórnika oraz regulatora napięcia. Ponadto przedstawiono wyniki pomiarów parametrów prototypowego układu scalonego wykonanego z użyciem technologii CMOS 0.35 um. Uzyskane wyniki porównano z rezultatami uzyskanymi w innych...
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublikacjaThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Experimental test results of an automatic voltage regulator with independent phase voltage controllers
PublikacjaThe growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...
-
Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation
PublikacjaThe constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....
-
The influence of SVC on the progress of voltage collapse
PublikacjaThe article presents the simulation concerning the cooperation of SVC circuit with a generative set in time, when of power system reaches low values which may lead to the fall-out of generator from the synchronous operation.
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublikacjaThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublikacjaThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors
PublikacjaThis paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...
-
Medium-Voltage Drives: Challenges and existing technology
PublikacjaThe article presents an overview of state-of-art solutions, advances, and design and research trends in medium-voltage (MV) drive technologies - and also discusses the challenges and requirements associated with the use of such drives. The choice and deployment of MV drives in industries are associated with numerous requirements related to the front-end converter (grid side) and inverter (machine side). The focus is on solutions...
-
Modular multipulse voltage source inverters with integrating coupled reactors
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...
-
Quality assessment of high voltage varistors by third harmonic index
PublikacjaHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublikacjaThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
A new approach to cross-bonding in medium voltage cable lines
PublikacjaThe medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublikacjaSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
Voltage Control of a Stand-Alone Multiphase Doubly Fed Induction Generator
PublikacjaThis article presents a multiphase doubly fed induction generator (MDFIG) with a dedicated and unique control algorithm in a stand-alone wind energy conversion system. The algorithm has been developed and elaborated in the case of different emergency modes. Compared with the traditional double-fed induction generator, the MDFIG has increased reliability, reduced current level per phase, and low rotor harmonic currents. The control...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublikacjaThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters
PublikacjaThe aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy...
-
Errors in the analysis of series resonant inverter/converter assuming sinusoidal waveforms of voltage and current
PublikacjaIn this paper the theory and simulation results of the series resonant inverter / converter are presented. In this work the authors carried out a detailed comparative analysis of results obtained using the method of AC analysis in the steady state for the first harmonic with the results of computer simulation. The AC analysis under certain conditions can lead to errors disqualifying this method. In particular, these errors appear...