Filtry
wszystkich: 1132
wybranych: 799
Wyniki wyszukiwania dla: MULTIFREQUENCY VOLTAGE PERTURBATION
-
The effect of a polyharmonic structure of the perturbation signal on the results of harmonic analysis of the current of a first-order electrode reaction
Publikacja -
Influence of the Square Wave Voltage on Dynamical Properties of a Flat Voltammetric Electrode in the Time Domain by the Electrochemical Reversible Reaction
PublikacjaIn this article there is a presentation of the analysis of the polarizing voltage shape influencing dynamic properties of voltammetric electrodes when on their surface reversible reaction takes place in the time domain. The electrode polarization with linearly increasing voltage and with a square component, was analyzed. The analysis that were conducted showed that the voltammetric electrode behaves like a first order transducer....
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublikacjaThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Hydro Power Plant in the Process of Voltage Control in the Electric Power System and the System Restoration
PublikacjaThe article covers selected issues related to the share of hydroelectric power in the process of rebuilding the power system after black-out and voltage control during that process. Selected results of measurements made during the creation of the transmission chain for the need to start a block of a thermal power plant from a hydroelectric power plant were presented.
-
New Architecture of Solid-State High-Voltage Pulse Generators
PublikacjaThe application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublikacjaThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
Effects of solution composition and electrophoretic deposition voltage on various properties of nanohydroxyapatite coatings on the Ti13Zr13Nb alloy
PublikacjaThe purpose of the research was to establish the influence of the solution composition and the electrophoretic deposition voltage on the coating homogeneity and thickness, nanohardness, adhesion, corrosion resistance and wettability. The Ti13Zr13Nb alloy was coated by the electrophoretic technique with hydroxyapatite in a solution containing 0.1, 0.2 or 0.5 g nanoHAp in 100 mL of suspension and at voltage 15, 30 or 50 V. The scanning...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
The Influence of Limiters UEL and OEL (The power angle, stator's current and excitation current) ot the possibility of voltage collapse development
PublikacjaVoltage stability has been a major concern for power system utilities because of event of voltage collapses in the recent past. Sometimes, power system events have shown the need for generators to operate in the overexcited and underexcited region to support stable operation. Modern excitation systems include devices for controlling or limiting machine terminal voltage (overvoltage limiters), volts per hertz ratio (V/Hz limiters),...
-
Study of the Operation of Synchronous Generator Voltage Regulator During the Creation of Post Blackout Start-up Path
PublikacjaThis paper presents the influence of automatic voltage regulator (AVR) of synchronous generator on the process of creation of post black-out start-up path. Two elements of AVR have a significant impact on this process: underexcitation limiter (UEL) and load compensation (LC). The authors present a theoretical investigation and simulation results that illustrate how the mentioned elements of AVR affect voltage levels in a power...
-
Voltage Control of a Stand-Alone Multiphase Doubly Fed Induction Generator
PublikacjaThis article presents a multiphase doubly fed induction generator (MDFIG) with a dedicated and unique control algorithm in a stand-alone wind energy conversion system. The algorithm has been developed and elaborated in the case of different emergency modes. Compared with the traditional double-fed induction generator, the MDFIG has increased reliability, reduced current level per phase, and low rotor harmonic currents. The control...
-
Hybridized Space-Vector Pulsewidth Modulation for Multiphase Two-Level Voltage Source Inverter
PublikacjaIn space vector pulsewidth modulation (SVPWM) algorithms for multiphase two-level voltage source inverters (VSI), the components of active vectors in all orthogonal spaces have to be calculated within the processor and stored in its memory. These necessitate intensive computational efforts of the processor and large memory space. This article presents a hybridized SVPWM for multiphase two-level VSI. In this algorithm, elements...
-
Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters
PublikacjaThe aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy...
-
Research of chitosan coatings deposited by electrophoretic deposition method at various voltage and time parameters
PublikacjaThe aim of this research is to estimate the electrophoretic deposition main parameters, such as voltage and time duration, that will provide optimal characteristics of the surface layer. Chitosan coatings were synthesized on biomedical Ti13Zr13Nb alloys at 20 V and 30 V and with deposit times of 2min, 5 min, 10 min, and 15 min. Evaluation of the coating was performed by using Scanning Electron Microscope (SEM), Energy-Dispersive...
-
Modified SPWM Technique with Zero-Sequence Voltage Injection for a Five-Phase, Three-Level NPC Inverter
PublikacjaThis article presents a modified sinusoidal pulse-width modulation (SPWM) scheme for a five-phase, three-level neutral-point-clamped inverter. The modulation scheme deploys a modified min–max function to inject the zero-sequence components into the reference modulating signals; hence enabling the effective utilization of the DC-link voltage. Balanced split-input DC-link voltages were achieved through further incorporation of adjustable...
-
Low voltage photovoltaic power system
PublikacjaThe use of photovoltaics is growing rapidly in the industry as well as households. Therefore, educating the public will help them understand solar cell technology, which is becoming more common in everyday life. This paper proposes a demonstrational set-up of photovoltaic panel for the purpose of science education. It was used in numerous outreach activities such as science fairs. Moreover, it proved to be a great tool for education...
-
High - voltage thin - layer fuses
PublikacjaZaprezentowano nową technologię i konstrukcję bezpieczników wysokonapięciowych wykorzystując technologie stosowane w mikroelektronice. Cienką warstwę topika naniesiono na quasiceramiczne podłoże. Wykonane modele bezpieczników charakteryzują się wysoką pewnością działania oraz małymi stratami I2t.
-
The influence of SVC on the progress of voltage collapse
PublikacjaThe article presents the simulation concerning the cooperation of SVC circuit with a generative set in time, when of power system reaches low values which may lead to the fall-out of generator from the synchronous operation.
-
Modern Arrangement for Reduction of Voltage Perturbations
PublikacjaThe contents of this chapter encompass general problems and the most important issues of power-supply-quality improvement in AC systems. In the context of the above, consideration is given to evaluation of bilateral interactions of receivers with an electrical power-distribution system and methods of their reduction. Also are discussed the basis of operation of the most important compensation-filtration devices and their applications...
-
Response of high voltage disconnector under seismic excitation - experimental and numerical study
PublikacjaThe efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublikacjaThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Space Vector Pulsewidth Modulation Strategy for Multilevel Cascaded H-Bridge Inverter With DC-Link Voltage Balancing Ability
PublikacjaSpace vector pulsewidth modulation (SVPWM) algorithms for cascaded H-bridge multilevel (CHB ML) inverter usually provide the possibility of using several combinations of active voltage vectors to generate the same output voltage vector. For preselected H-bridges, some of them may generate output voltages opposite to the assumed direction. This results in the change of the dc-link voltages of these H-bridges in the opposite direction...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
A DFT+U study of carbon nanotubes under influence of a gate voltage
PublikacjaA possibility of appearance of antiferromagnetic ordering in armchair carbon nanotubes and graphene is studied using density functional theory within a DFT+U approach. It is shown that the Coulomb repulsion between electrons in the -orbitals of graphene would need to reach a threshold value of ,...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublikacjaThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublikacjaFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Four Level Diode-Clamped Back-To-Back Converter with Active DC Link Voltage Control
PublikacjaThis article presents the design and control of 4L-DC back-to-back converter. To solve the DC link voltage balancing problem in four-level converter a new three-level double chopper topology based on PO-PWM modulation was designed and successfully tested. Also, the paper describes two phase space vector pulse width modulation 2P-SVPWM based on the shape function of finite elements. The control structure with modified Dead-Beat...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublikacjaThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publikacjahe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublikacjaThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Efficient Analysis of Noise Induced in Low-Voltage Installations Placed Inside Buildings with Lightning Protection Systems
PublikacjaThis paper describes an efficient approach to the broadband analysis of lightning protection systems (LPSs) using the method of moments (MoM) implemented in the frequency domain. The adaptive frequency sampling (AFS) algorithm, based on a rational interpolation of the relevant observable (e.g., voltage, current, electric or magnetic field) which describes the properties of the LPS, is employed to reduce the number of samples computed...
-
Modeling of a Quasi-Resonant DC Link Inverter Dedicated to Common-Mode Voltage and Ground Current Reduction
PublikacjaIn this paper, the modeling methodology of the AC drive system with a Parallel Quasi-Resonant DC Link Inverter (PQRDCLI) is described. A presented modeling approach is an attractive tool used for the effective evaluation of a common-mode (CM) voltage and grounds current reduction methods. Designed models of inverter, induction machine (IM), and cable are simple, thus the methods for parameter extraction are not complicated. Verification...
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublikacjaThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Laboratory tests of medium voltage switchgear isolators
Publikacja -
Increase of Diagnostic Capabilities of Voltage Fluctuation Indicies
Publikacja -
The Phenomena of Bursts by Opening Low-Voltage Relay
Publikacja -
Diagnostics of high-voltage varistors by acoustic emission
PublikacjaWarystory, szeroko stosowane w ogranicznikach przepięć, powinny być testowane na końcowym etapie ich wytwarzania. Stosowane metody testowania wymagają użycia wysokich napięć i prądów o dużych natężeniach, co jest nidogodne, destrukcyjne i wymaga poboru relatywnie dużych pocy. W artykule zaproponowano zastosowanie analizy sygnału emisji akustycznej do predykcji jakości struktury warystora. Opisano system przygotowany do tej aplikacji,...
-
An improved adaptive neural voltage controller for turbogenerator
PublikacjaOpracowano model adaptacyjnego neuronowego regulatora napięcia z nastrojonym współczynnikiem wzmocnienia funkcji przynależności i z nastrojonym współczynnikiem uczenia sieci neuronowej w zależnosci od stanu obciążenia turbogeneratora. Przedstawiono wyniki symulacji mające na celu badania efektywności proponowanego regulatora. Te wyniki porównano z wynikami uzyskanymi z regulatorem o stałym współczynnikiem wzmocnienia funkcji przynależności...
-
Predictive Current Control of Voltage-Source Inverter.
PublikacjaW artykule przedstawiono regulator prądu stojana silnika asynchronicznego z predykcją napiecia wyjściowego. Rozważono aspekty praktycznej realizacji algorytmu w układzie z procesorem sygnałowym związane z opóźnieniami pomiaru prądu przy zastosowaniu przetwornika A/C. Układ zrealizowano praktycznie przy wykorzystaniu układu FPGA. W pracy zamieszczono wyniki badań symulacyjnychi eksperymentalnych.
-
Problems of exact generation ofinverter output voltage
PublikacjaW pracy przedstawiono nową modyfikację modulatora szerokości impulsów. Rozważono problemy generacji dokładnej wartości napięcia wyjściowego falownika. Zaproponowano dwie metody generacji małej wartości napięcia.
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries
PublikacjaThe paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublikacjaThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublikacjaThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Optimization of Division and Reconfiguration Locations of the Medium-Voltage Power Grid Based on Forecasting the Level of Load and Generation from Renewable Energy Sources
PublikacjaThe article addresses challenges in optimizing the operation of medium voltage networks, emphasizing optimizing network division points and selecting the best network configuration for minimizing power and energy losses. It critically reviews recent research on the issue of network configuration optimization. The optimization of the medium voltage power grid reconfiguration process was carried out using known optimization tools....