Filtry
wszystkich: 1599
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: GAMMA-RAY ABSORPTION
-
Evaluation of the structures size in the liquid-gas flow by gamma-ray absorption
PublikacjaThe rapid development of tomography methods particularly electrical, X and gamma rays allows for a wide range of the information about flow structure. However, all of such methods are quite complicated. At the same time much simpler systems as the measuring system of gamma rays absorption, allows to obtain a all key flow information which describe the two-phase flow. In the article the results of analyzes of radiometric signal...
-
Signal Processing in the Investigation of Two-phase Liquid-gas Flow by Gamma-ray Absorption
Publikacjan this paper, the use of the gamma-absorption method applied in the investigation of the two-phase liquid-gas flow in the pipeline is described. An example of its application to the air transported by water in a horizontal pipeline is evaluated. In the measurements, Am-241 radioactive sources and probes with Nal (Tl) scintillation crystals have been used. The signals from the radiometric set were used to determine the velocity...
-
EVALUATION OF LIQUID-GAS FLOW IN PIPELINE USING GAMMA-RAY ABSORPTION TECHNIQUE AND ADVANCED SIGNAL PROCESSING
PublikacjaLiquid-gas flows in pipelines appear in many industrial processes, e.g. in the nuclear, mining, and oil industry. The gamma-absorption technique is one of the methods that can be successfully applied to study such flows. This paper presents the use of thegamma-absorption method to determine the water-air flow parameters in a horizontal pipeline. Three flow types were studied in this work: plug, transitional plug-bubble,...
-
Two-phase water-air flow measurement using gamma-ray absorption technique – plug flow
Dane BadawczeThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: plug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC...
-
Two-phase water-air flow measurement using gamma-ray absorption technique – slug flow
Dane BadawczeThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: slug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC...
-
Two-phase water-air flow measurement using gamma-ray absorption technique –bubble flow
Dane BadawczeThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: bubble flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated...
-
CdWO/sub 4/ crystal in gamma-ray spectrometry
Publikacja -
Two-phase water-air flow measurement using gamma-ray absorption technique – transitional plug – bubble flow
Dane BadawczeThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: transitional plug – bubble flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded...
-
Confined lead nanogranules investigated by X-ray absorption spectroscopy
Publikacja.
-
Development of a digital method for neutron/gamma-ray discrimination based on matched filtering
Publikacja -
Performance of a fuel cell optimized for in situ X-ray absorption experiments
PublikacjaKomercyjna komórka ogniwa paliwowego typu PEM została zmodyfikowana w celu realizacji pomiaru XAS w warunkach pracy ogniwa. Modyfikacja komórki miała na celu optymalizację jej parametrów pod kątem eksperymentu XAS realizowanego w modzie transmisyjnym i fluorescencyjnym, poprzez minimalizację absorpcji komórki, przy zachowaniu jej parametrów elektrochemicznych. W pracy zostały zaprezentowane szczegóły techniczne komórki a jej efektywność...
-
X-ray absorption fine structure and x-ray diffraction studies of crystallographic grains in nanocrystalline FePd:Cu thin films
Publikacja -
Testing interaction models by using x-ray absorption spectroscopy: solid Pb
PublikacjaPraca prezentuje zastosowanie metody EXAFS jako narzędzia do testowania potencjałów oddziaływań międzyatomowych używanych w symulacjach dynamiczno-molekularnych na przykładzie czystego ołowiu w fazie stałej (od temperatury pokojowej do temperatury topnienia). Testowaniu poddano następujące potencjały: dwuciałowy empiryczny potencjał Dzugutova, Larssona i Ebbsjo (DLE), potencjał ciasnego wiązania (TB) i potencjał w modelu osadzonego...
-
<title>Search for optical flashes accompanying gamma ray bursts Pi of the Sky collaboration</title>
Publikacja -
SEI Growth and Depth Profiling on ZFO Electrodes by Soft X-Ray Absorption Spectroscopy
PublikacjaZnFe2O4 (ZFO) Li-ion batteries (LIBs) represent a reliable, affordable, and safe energy storage technology for use in portable application. However, current LIB active materials (graphite, lithium/transition metal spinel or layered oxides, olivine structures) can store only limited energy since they rely on insertion storage based on solid-state host-guest interactions. Moreover, performances and durability of the cells are strongly...
-
Enhancing Luminescence and X-ray Absorption Capacity of Eu3+:LaF3 Nanoparticles by Bi3+ Codoping
Publikacja -
The bismuth atom neighbourhood in bismuth-silicate glasses from X-ray absorption experiment
PublikacjaPraca zawiera wyniki strukturalnej analizy EXAFS lokalnego otoczenia atomów bizmutu w krystalicznym tlenku bizmutu (odmiana alfa) i w szklach bizmutowo-krzemianowych o składzie xBi2O3 (1-x)SiO2,x=0.3, 0.4, 0.5, 0.6. Analizę XA- FS realizowano w oparciu o metodę GNXAS. Otrzymane wyniki porównano z danymi literaturowym.
-
Investigation of Liquid–Gas Flow in a Horizontal Pipeline Using Gamma-Ray Technique and Modified Cross-Correlation
PublikacjaThis article presents the application of the radioisotope absorption method in the study of two-phase water–air flow in a horizontal pipe. The measurement principle and the test stand are briefly described. The main part of the article presents the signal analysis methods applied to data obtained from scintillation detectors. Because these signals are mostly stochastic waveforms, they were analyzed statistically using the cross-correlation...
-
A TPC Detector for Studying Photo-nuclear Reactions at Astrophysical Energies with Gamma-ray Beams at ELI--NP
Publikacja -
/sup 6/LiI(Eu) in neutron and /spl gamma/-ray spectrometry-a highly sensitive thermal neutron detector
Publikacja -
Measurements of Dispersed Phase Velocity in Two-Phase Flows in Pipelines Using Gamma-Absorption Technique and Phase of the Cross-Spectral Density Function
PublikacjaThis paper concerns the application of the gamma radiation absorption method in the measurements of dispersed phase velocity in two-phase flows: liquid–gas flow in a horizontal pipe- line and liquid–solid particles in a vertical pipe. Radiometric sets containing two linear 241Am gamma radiation sources and two NaI(Tl) scintillation detectors were used in the research. Due to the stochastic nature of the signals obtained from the...
-
Local structural and chemical ordering of nanosized Pt(3±δ)Co probed by multiple-scattering x-ray absorption spectroscopy
PublikacjaThis work reports a detailed investigation of the local structure and chemical disorder of a Pt(3±δ)Co thin film and Pt(3±δ)Co nanoparticles. We have used a combination of techniques including x-ray absorption spectroscopy (XAS), x-ray diffraction (XRD), and high-resolution transmission electron microscopy (TEM). The important effect of chemical ordering on pair and three-atom configurations has been studied using computer simulations...
-
Time Delay Estimation in Two-Phase Flow Investigation Using the γ-Ray Attenuation Technique.
PublikacjaTime delay estimation is an important research question having many applications in a range of technologies. Measurement of a two-phase flow in a pipeline or an open channel using radioisotopes is an example of such application. For instance, the determination of velocity of dispersed phase in that case is based on estimation of the time delay between two stochastic signals provided by scintillation probes. The proper analysis...
-
Comparison of noise reduction methods in radiometric correlation measurements of two-phase liquid-gas flows
PublikacjaTwo-phase liquid-gas flows occur frequently in the mining, energy, chemical, and petrochemical industries. One of non-contact methods used to analyse these flows is the gamma ray absorption method. However, the signals received from radiation detectors contain a significant stochastic noise, which makes them difficult to analyse. The article describes four methods of noise reduction in cross-correlation measurements of water-air...
-
Agnieszka Witkowska dr hab. inż.
Osoby -
Signals Features Extraction in Radioisotope Liquid-Gas Flow Measurements using Autocorrelation Function
PublikacjaKnowledge of the two-phase flow structure is essential for the proper conduct of industrial processes. Description of liquid-gas flow regimes is possible by using of data analysis in time, frequency, or state-space domain. In this research studies, the autocorrelation function is applied for analysis of signals obtained for liquid-gas flow by use gamma-ray absorption. The experiments were carried out on the laboratory hydraulic...
-
Signals features extraction in radioisotope liquid-gas flow measurements using wavelet analysis
PublikacjaKnowledge of the structure of a flow is significant for the proper conduct of a number of industrial processes. In this case, a description of a two-phase flow regimes is possible by use of the time-series analysis in time, frequency and state-space domain. In this article the Discrete Wavelet Transform (DWT) is applied for analysis of signals obtained for water-air flow using gamma ray absorption. The presented method was illustrated...
-
XPS data of deuterium and hydrogen grown boron-doped diamond
Dane BadawczeThe high-resolution C1s X-ray absorption spectra of BDD@H and BDD@D samples were measured using the facilities of the HE-SGM beamline (HE-SGM) at the BESSY II synchrotron radiation source of Helmholtz–Zentrum Berlin (HZB).[90] The measurements were carried out under ultra-high vacuum conditions: P ≈ 2×10−9 Torr at T = 300 K. The NEXAFS spectra were...
-
Measurements of Two-phase Flows in Pipelines Using Radioisotopes and Statistical Signal Processing
PublikacjaThis paper presents an application of radiotracers and gamma absorption method in two-phase flow measurements in pipelines. Two different methods were implemented to analysis of acquired signals. Investigated methods are based on the cross-correlation function and the phase of the cross-spectral density distribution. The examples presented in the article illustrate the application of the radioisotopes to evaluation of liquid-gas...
-
The XAS spectra of O-K edges, Fe-L edges in pristine, La-, and Nb-doped SFM in 3 states: as-prepared, reduced and reoxidized
Dane BadawczeThis dataset contains the normalized and exported to *.txt spectra for x-ray absorption spectroscopy. The samples analyzed were strontium ferrite molybdate based, doped with lanthanum and niobium. The powders were measured in as-prepared state (denoted in filename as AP), reduced (red) and reoxidized (reox). The filenames are written accordingly: Edge_(optional:...
-
Radioisotope measurements of the liquid-gas flow in the horizontal pipeline using phase method
PublikacjaThe paper presents application of the gamma-absorption method to a two-phase liquid-gas flow investigation in a horizontal pipeline. The water-air mixture was examined by a set of two Am-241 radioactive sources and two NaI(Tl) scintillation probes. For analysis of the electrical signals obtained from detectors the cross-spectral density function (CSDF) was applied. Results of the gas phase average velocity measurements for CSDF...
-
Application of ANN and PCA to two-phase flow evaluation using radioisotopes
PublikacjaIn the two-phase flow measurements a method involving the absorption of gamma radiation can be applied among others. Analysis of the signals from the scintillation probes can be used to determine the number of flow parameters and to recognize flow structure. Three types of flow regimes as plug, bubble, and transitional plug – bubble flows were considered in this work. The article shows how features of the signals in the time and...
-
The luminescence study ofNaK2Li[Li3SiO4]4:Ce coumpounds.
Dane BadawczePhosphors with a rigid and symmetrical structure are urgently needed. The alkali lithosilicate family (A[Li3SiO4]) has been extensively studied with a narrow emission band due to its unique cuboid-coordinated environment and rigid structure. However, here we demonstrate for the first time Ce-doped NaK2Li[Li3SiO4]4 phosphors with a broad emission band,...
-
The luminescence study of Bi-doped Cs2AgInCl6 double perovskite.
Dane BadawczeHere, we report a halide precursor acid precipitation method to synthesize Cs2AgIn1−xBixCl6 (x = 0, 0.02, 0.04, 0.08, 0.16, 0.32, 0.64, and 1) microcrystals. Cs2AgInCl6 and Bi derivative double perovskites show broadband white light emission via self-trapped excitons (STEs) and have achieved the highest internal quantum efficiency of up to 52.4% at...
-
Selected aspects of modern X-ray structural analysis 2024
Kursy OnlineSelected Aspects of Modern X-ray Structural Analysis
-
Selected Aspects of Modern X-ray Structural Analysis 2023
Kursy OnlineSelected Aspects of Modern X-ray Structural Analysis
-
Dissecting gamma frequency activities during human memory processing
PublikacjaGamma frequency activity (30-150 Hz) is induced in cognitive tasks and is thought to reflect underlying neural processes. Gamma frequency activity can be recorded directly from the human brain using intracranial electrodes implanted in patients undergoing treatment for drug-resistant epilepsy. Previous studies have independently explored narrowband oscillations in the local field potential and broadband power increases. It is not...
-
Gamma oscillations precede interictal epileptiform spikes in the seizure onset zone
PublikacjaOBJECTIVE: To investigate the generation, spectral characteristics, and potential clinical significance of brain activity preceding interictal epileptiform spike discharges (IEDs) recorded with intracranial EEG. METHODS: Seventeen adult patients with drug-resistant temporal lobe epilepsy were implanted with intracranial electrodes as part of their evaluation for epilepsy surgery. IEDs detected on clinical macro- and research microelectrodes...
-
Wartości współczynnika N-gamma uzyskane z badań modelowych.
PublikacjaW artykule przedstawiono wyniki badań modelowych nośności jednorodnego podłoża gruntowego ograniczonego warstwą nieodkształcalną i obciążonego fundamentem pasmowym. Wyznaczono wartości współczynnika nośności N-gamma oraz skorygowanego N-gamma, prim, które porównano z istniejącym rozwiązaniem teoretycznym Mandela i Salencona.
-
Apparent molar volumes and compressibilities of electrolytes and ions in gamma-butyrolactone
PublikacjaW oparciu o zmierzone wartości gęstości roztworów i rozpuszczalnika w temperaturach od 15 do 40oC wyznaczono pozorne molowe objętości bromku litu, nadchloranu litu, nadchloranu sodu, tetrafenyloboranu sodu oraz bromku tetrafenylofosfoniowego w gamma-butyrolaktonie. Ponadto, wyznaczone prędkości rozchodzenia się dźwięku w 25oC w badanych układach pozwoliły obliczyć pozorne molowe ściśliwości wybranej grupy soli. Uzyskane (w wyniku...
-
Paenibacillus alvei MP1 as a Producer of the Proteinaceous Compound with Activity against Important Human Pathogens, Including Staphylococcus aureus and Listeria monocytogenes
PublikacjaAn emerging need for new classes of antibiotics is, on the one hand, evident as antimicrobial resistance continues to rise. On the other hand, the awareness of the pros and cons of chemically synthesized compounds’ extensive use leads to a search for new metabolites in already known reservoirs. Previous research showed that Paenibacillus strain (P. alvei MP1) recovered from a buckwheat honey sample presented a wide spectrum of...
-
Study of the Layer-Type BST Thin Film with X-ray Diffraction and X-ray Photoelectron Spectroscopy
PublikacjaIn the present paper, results of X-ray photoelectron studies of electroceramic thin films of barium strontium titanate, Ba1xSrxTiO3 (BST), composition deposited on stainless-steel substrates are presented. The thin films were prepared by the sol-gel method. A spin-coating deposition of BST layers with different chemical compositions was utilized so the layer-type structure of (0-2) connectivity was formed. After the deposition,...
-
Direct electrical stimulation of the human brain has inverse effects on the theta and gamma neural activities
PublikacjaObjective: Our goal was to analyze the electrophysiological response to direct electrical stimulation (DES) systematically applied at a wide range of parameters and anatomical sites, with particular focus on neural activities associated with memory and cognition. Methods: We used a large set of intracranial EEG (iEEG) recordings with DES from 45 subjects with electrodes...
-
Maciej Wróbel dr inż.
OsobyReceived PhD from Gdańsk University of Technology in 2019. Research interests involve non-invasive applications of Raman spectroscopy for tissue analysis, specifically blood parameters measurements. Tissue mimicking phantoms, measurement of optical properties (scattering, absorption), as well as other optical sensing methods. Raman spectroscopy and surface-enhanced Raman spectroscopy (SERS) utilized for measurements of biological...
-
Highly porous nanoberyllium for X-ray beam speckle suppression
PublikacjaThe speckle suppressor device containing highly porous nanoberyllium is proposed for manipulating with the spatial coherence length and removing undesirable speckle structure during the imaging experiments. We report a special device called the speckle suppressor, which contains the highly porous nanoberyllium plate, compacted from both sides by two beryllium windows. By insertion the speckle suppressor in the X-ray beam it allows...
-
The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures
PublikacjaBackground: Intertrochanteric fractures may occur in a bone with a wide medullary canal that may lead to significant mobility of a intramedullary nail, contrary to an extramedullary device. This study evaluates the Dynamic Hip Screw and the gamma nail in AO 31.A2.1 fractures in these circumstances. Methods: Synthetic femora with canals drilled to 18 mm were used. Five fixation types were examined: a 2 - hole and a 4 – hole Dynamic...
-
X-RAY SPECTROMETRY
Czasopisma -
Evolution of Ag nanostructures created from thin films: UV–vis absorption and its theoretical predictions
PublikacjaAg-based plasmonic nanostructures were manufactured by thermal annealing of thin metallic films. Structure and morphology were studied using scanning electron microscopy (SEM), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HR-TEM) and X-ray photoelectron spectroscopy (XPS). SEM images show that the formation of nanostructures is influenced by the initial layer thickness as well as the...
-
High resolution X-ray diffractometry and reflectometry of semiconductor nano- and micro- structures based on X-ray refractive optics
PublikacjaIn this thesis proposed, discussed and studied novel synchrotron X-ray diffractometry and reflectometry methods based on a refractive optics. The experimental results obtained from the ID06 beamline at ESRF, Grenoble, France are presented and analyzed in this work to demonstrate a high angular and space resolution in addition to the opportunity to manage in situ and on operando experiments with the help of proposed X-ray optical...
-
Concentrations of alfa- and gamma- tocopherols in human breast milk during the first months of lactation and in infant formulas
PublikacjaThe aim of this study was to determine the concentrations of alpha- and gamma-tocopherols in human breast milk samples from different periods of lactation and to compare them with tocopherol content in commercially available formulas for infants at corresponding ages. The study included 93 breast milk samples obtained on the 2nd (colostrum, n=17), 14th (n=30), 30th (n=27) and 90th day of lactation (n=19), along with 90 samples...