Filtry
wszystkich: 1626
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: allergy to implant components
-
New 3D printable filaments with nanodiamonds, physicochemical additives characteristics and electrochemical activity
Dane BadawczeThis dataset contains the physicochemical analyses (XRD, Raman spectroscopy, BET analyses) and electrochemical analyses (CV, EIS) for a new 3D-printable composite has been developed dedicated to electroanalytical applications. Two types of diamondised nanocarbons - detonation nanodiamonds (DNDs) and boron-doped carbon nanowalls (BCNWs) - were added...
-
9 - Solid oxide fuel and electrolysis cells
PublikacjaIn this chapter, the fundamental reactions, the geometrical designs, the material requirements, and the status of SOFCs and SOECs are presented. In the following seven chapters, the most important components of an SOC are described and the chapter ends with a summary and outlook. The described components are: (i) oxygen-ion conductors (electrolyte), (ii) anode materials for SOFCs (cathode in SOEC mode), (iii) cathode materials...
-
Local Mesh Deformation for accelerated parametric studies based on the Finite Element Method
PublikacjaThis paper presents an approach for enhancing the efficiency of two-dimensional Finite Element Method analysis in parametric studies or optimisation process of microwave components. The new approach involves local mesh deformation applied near the elements that are modified during computations. Since in the proposed approach the topology of the mesh remains unchanged, a new mesh does not have to be generated from scratch when the...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Environmental impact and industrial development of biorenewable resources for polyurethanes
PublikacjaPolyurethanes are among the most developed types of polymers. They are produced from the three primary components, i.e., polyols, low-molecular-weight glycols used as chain extenders, and diisocyanates. Until recently, all these substrates have been obtained via petrochemical processes. A decrease in petroleum-based resources and new ecological trends in chemistry, chemical technology, and materials engineering have generated increasing...
-
Titania Nanotubes/Hydroxyapatite Nanocomposites Produced with the Use of the Atomic Layer Deposition Technique: Estimation of Bioactivity and Nanomechanical Properties
PublikacjaTitanium dioxide nanotubes/hydroxyapatite nanocomposites were produced on a titanium alloy (Ti6Al4V/TNT/HA) and studied as a biocompatible coating for an implant surface modification. As a novel approach for this type of nanocomposite fabrication, the atomic layer deposition (ALD) method with an extremely low number of cycles was used to enrich titania nanotubes (TNT) with a very thin hydroxyapatite coating. X-ray diffraction (XRD)...
-
Nanoindentation tests titanium alloy Ti-6Al-4V after interference laser treatment
PublikacjaThe study aimed was to assess selected mechanical properties of surface layers obtained after interference laser treatment – DLIL of titanium alloy Ti-6Al-4V used for implants. The samples were melted in still air at room temperature, for this purpose Nd:YAG laser was used, the number of laser shots was variable. Next, nanoindentation tests were performed, based on which Young’s modulus and nanohardness in the obtained surface...
-
EXAMINATION OF SOL-GEL DERIVED HYDROXYAPATITE ENHANCED WITH SILVER NANOPARTICLES USING OCT AND RAMAN SPECTROSCOPY
PublikacjaHydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements...
-
Recent advances in electrochemically surface treated titanium and its alloys for biomedical applications: A review of anodic and plasma electrolytic oxidation methods
PublikacjaNowadays, titanium and its alloys are widely used materials in implantology. Nevertheless, the greatest challenge is still its appropriate surface treatment in order to induce optimal properties, which facilitates formation of a permanent bond between the implant and human tissue. The use of electrochemical treatment such as anodic oxidation or plasma electrolytic oxidation allows for the production of porous coating that mimics...
-
Wpływ warunków spawania na skłonność do tworzenia pęknięć zimnych przy spawaniu pod wodą
PublikacjaPrzedmiotem pracy było określenie skłonności do tworzenia pęknięć zimnych złączy spawanych ze stali 18G2A wykonanych pod wodą metodą lokalnej komory suchej. Problem rozwiązano przy zastosowaniu teorii planowania badań. Określono ilościowy wpływ parametrów spawania: wydatku gazu osłonowego oraz energii liniowej spawania na naprężenia krytyczne z próby implant, wskaźnik skłonności do tworzenia pęknięć zimnych, twardość maksymalną...
-
Powikłania po rekonstrukcji piersi: problem zakażeń i strategii prewencyjnej - przegląd literaturowy
PublikacjaW niniejszej pracy przedstawiono dane dotyczące powikłań po rekonstrukcji piersi. Manuskrypt ma na celu usystematyzowanie wyników badań z ostatnich lat wraz z aspektami, takimi jak: częstotliwość występowania powikłań oraz ich rodzaj, czynniki predysponujące, a także możliwości profilaktyki. Przeanalizowano dane literaturowe z ogólnie dostępnych artykułów z okresu ostatnich pięciu lat, ze szczególnym uwzględnieniem zakażeń. Do...
-
Noise sources in Raman spectroscopy of biological objects
PublikacjaWe present an overview of noise sources deteriorating the quality of the recorded biological Raman spectra and the ability to determine the specimen composition. The acquired Raman spectra exhibit intense additive noise components or drifts because of low intensity of the scattered light. Therefore we have to apply expensive or bulky measurement setups to limit their inherent noise or to apply additional signal processing to reduce...
-
Mechanical Properties of 3D Printed Parts and Their Injection Molded Alternatives Subjected to Environmental Aging
PublikacjaAdditive manufacturing is the technology used in medical, industrial, or lifestyle applications. The scientific literature include works reporting various manufacturing parameters’ influence on changes in additive manufacturing components’ mechanical behavior, especially with fused filament fabrication (FFF). The changes in mechanical strength and toughness of FFF compared to injection molding parts were studied. In the study,...
-
Slowly-closing valve behaviour during steam machine accelerated start-up
PublikacjaThe paper discusses the state of stress in a slowly-closing valve during accelerated start-up of a steam turbine. The valve is one of the first components affected by high temperature gradients and is a key element on which the power, efficiency and safety of the steam system depend. The authors calibrated the valve model based on experimental data and then performed extended Thermal-FSI analyses relative to experiment. The issue...
-
Development of methods improving storage stability of bitumen modified with ground tire rubber: A review
PublikacjaThe following paper presents an overview of methods for improving the storage stability at high temperature of rubber modified bitumen. The storage stability of the rubber modified bitumen can be improved by using a various types of modifiers that form the bonds between the components of these binders. The increase in stability can also be achieved by using crumbrubber surface-activated by furaldehyde or ground tire rubber (GTR)...
-
UNDERWATER NOISE GENERATED BY A SMALL SHIP IN THE SHALLOW SEA
PublikacjaStudy of the sea noise has been a subject of interest for years. The first work of this scope were published at the turn of the twentieth century by Knudsen (KNUDSEN et al., 1948) and G. Wenz (WENZ, 1962). Disturbances called "shipping noise" are one of the important components of the sea noise. In this work the results of an experimental research of underwater noise produced by a small ship of a classic propulsion are...
-
The Role of Proteins in Food
PublikacjaThis chapter describes the effect of proteins on the sensory attributes and the biological value and safety of foods. The role of proteins depends on their amino acid composition and structure, on changes due to storage and processing, as well as on interactions with other food components. The effect on the sensory quality of foods is brought about by hydrophobicity, solubility, water holding capacity, gelling, film formation,...
-
Asymmetrical Modes in Polyphase Motors and Drives
PublikacjaThe effect of power supply and/or motor asymmetry on the phase-load distribution and the ripple of electromagnetic torque in a polyphase drive is studied by the method of symmetrical components. It is shown that the presence of asymmetry causes the mapping of all harmonics in the supply voltage into all planes of symmetrical components and eliminates the possibility of independent control of harmonics. The dynamic model of a five-phase...
-
System sejsmiki refleksyjnej do poszukiwania morskich złóż węglowodorowych
PublikacjaW poszukiwaniu morskich złóż węglowodorowych wykorzystywane są różne metody zaliczane do tzw. sejsmiki refleksyjnej. Jedną z nich jest wykorzystanie systemu sejsmiki refleksyjnej holowanego za statkiem specjalistycznym przeznaczonym do badań sejsmicznych. Jest to złożony ruchomy układ techniczny składający się z wielu elementów składowych, takich jak: system wzbudzania fal akustycznych, system rejestracji odbijanych fal akustycznych...
-
Lipofibroadenoma - Female, 33 - Tissue image [6070730010415521]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [704024710495891]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031821481]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824921]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031826611]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824591]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031825091]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [7040347232569211]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031823021]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031829301]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824721]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Fibroadenoma, NOS - Female, 47 - Tissue image [6070730010413861]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031828861]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031826781]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031824291]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Fibroadenoma, NOS - Female, 47 - Tissue image [6070730010418851]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031821141]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [521073003182701]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031826241]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031827511]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031823601]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031827961]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031822081]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
Wilms tumor - Male, 11 - Tissue image [5210730031825701]
Dane BadawczeThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
High meniscal slope angle as a risk factor for meniscal allograft extrusion
PublikacjaA meniscal graft extrusion is still an unresolved problem that affects most patients after a meniscal transplantation. Despite the advances in surgical techniques, together with the improved methods for a meniscal allograft sizing, success is only observed in up to 75% of patients after they experience a meniscal allograft transplantation. Because a meniscal extrusion is associated with a cartilage deterioration and the progression...
-
Antimicrobal and ostheointegration activity of bone cement contains nanometals
PublikacjaPurpose: One of the major problems in bone surgery are infections – especially thoseoccurring in the course of the operating on the patients with lowered immunity system,because they carry the danger of complications. In the Mechanical Department of TechnicalUniversity of Gdansk, there has been carried the research with the use of bone cement andmetal nanoparticles.Design/methodology/approach: The bone cement was used without supplement...
-
Degradation of implantable materials – in vivo and in vitro research
PublikacjaThe article concerns the biological and electrochemical degradation of metallic implants in vivo and in vitro studies. The in vivo research dealt with degradation of plates used to join bones, as well as endoprostheses. The most common damages were: metalosis, breaking in the microstructure changes, breaking in area of holes, as well as plastic deformation throughout the length of an implant. The material used for the research...
-
A Probe into the Corrosion Behavior of a WE43B Magnesium Alloy in a Simulated Body Fluid using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaWE43B is one of the newest Mg alloys with practical application in biomedical implant technology. This work attempts to scrutinize the corrosion characteristics of WE43B alloy in a simulated body fluid (SBF) at a typical body temperature. The dynamic-electrochemical impedance spectroscopy with the capacity to track changes on surfaces in a dynamic corrosive system is used in combination with other classical techniques namely, linear...
-
Effect of double thermal and electrochemical oxidation on titanium alloys for medical applications
PublikacjaThe research focuses on the development and characterization of innovative thin hybrid oxide coatings obtained in subsequent processes of thermal (TO) and electrochemical (EO) oxidation. Four different surface modifications were investigated and the microstructure was determined, the mechanical, chemical and biological properties of the Ti-13Nb-13Zr alloy were assessed using scanning electron microscopy, X-ray dispersion analysis,...
-
Introduction to the RSC Advances themed collection on nano and microscale modifications of biomaterials
PublikacjaThe dramatically increasing development of novel biomaterials, their manufacturing techniques, and surface modications, as well as their application in in vivo tests and clinical trials, is evident. It is interesting to note in what a relatively short time the well-known long-term implants have become medical standard: titanium dental implants started in 1965, and total hip arthroplasty (not very successful) was rst attempted...
-
Technology of an adhesive silicone film as drug carrier in transdermal therapy I. Analytical methods used for characterization and design of the universal elastomer layers
PublikacjaSilicone polymers possess unique properties, which make them suitable for many different applications, for example in the pharmaceutical and medical industry. To create an adhesive silicone film, the appropriate silicone components have to be chosen first. From these components two layers were made: an adhesive elastomer applied on the skin, and a non-adhesive elastomer on the other side of the film. The aim of this study was...