Filtry
wszystkich: 1660
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: REAL-TIME SIGNAL PROCESSING
-
A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters
PublikacjaMultiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...
-
Subjective Quality Evaluation of Speech Signals Transmitted via BPL-PLC Wired System
PublikacjaThe broadband over power line – power line communication (BPL-PLC) cable is resistant to electricity stoppage and partial damage of phase conductors. It maintains continuity of transmission in case of an emergency. These features make it an ideal solution for delivering data, e.g. in an underground mine environment, especially clear and easily understandable voice messages. This paper describes a subjective quality evaluation of...
-
Calibration-Free Single-Anchor Indoor Localization Using an ESPAR Antenna
PublikacjaIn this paper, we present a novel, low-cost approach to indoor localization that is capable of performing localization processes in real indoor environments and does not require calibration or recalibration procedures. To this end, we propose a single-anchor architecture and design based on an electronically steerable parasitic array radiator (ESPAR) antenna and Nordic Semiconductor nRF52840 utilizing Bluetooth Low Energy (BLE)...
-
Dynamic GNSS Mission Planning Using DTM for Precise Navigation of Autonomous Vehicles
PublikacjaNowadays, the most widely used method for estimating location of autonomous vehicles in real time is the use of Global Navigation Satellite Systems (GNSS). However, positioning in urban environments using GNSS is hampered by poor satellite geometry due to signal obstruction created by both man-made and natural features of the urban environment. The presence of obstacles is the reason for the decreased number of observed satellites...
-
Hardware-Software Implementation of Basic Principles Simulator of Nuclear Reactor Processes
PublikacjaThe paper presents implementation process of basic principle simulators of a nuclear reactor processes. Simulators are based on point-models of processes: kinetics of neutrons, heat generation and exchange, poisoning and burning-up nuclear fuel. Reference simulator was developed in MATLAB/Simulink without taking into account real-time operation. Second simulator was built using the toolbox xPC with hard real-time requirements....
-
EEG data recorded in three mental states
Dane BadawczeElectroencephalographic (EEG) signals were acquired from 17 (14 males, 3 females) participants aged between 20 and 30 years.
-
Hardware-Software Implementation of a Sensor Network for CityTraffic Monitoring Using the FPGA- and ASIC-Based Sensor Nodes
PublikacjaArtykuł opisuje prototypową sieć sensorową do monitorowania ruchu pojazdów w mieście. Węzły sieci sensorowej, wyposażone w kamerę o niskiej rozdzielczości, obserwują ulice i wykrywają poruszające się obiekty. Detekcja obiektów jest realizowana w oparciu o własny algorytm segmentacji obrazów, wykorzystujący podwójne odejmowanie tła, wykrywanie krawędzi i cieni, działający na dedykowanym systemie mikroelektronicznym typu ''System...
-
Parametric impulsive noise detector for corrupted audio signals based on hidden Markow model
PublikacjaThe paper addresses the problem of impulsive noise detection for audio signals. A structure of threshold parameter detectors using modelingof signals was introduced. the algorithm of the noise detection, based on discrete-time hidden Markow model (HMM)of whitened audio signal is elaborated
-
Using phase of short-term Fourier transform for evaluation of spectrogram performance
PublikacjaThe concept of spectrogram performance evaluation which exploits information on phase of short-term Fourier transform (STFT) is presented. A spectrograph which is time-frequency analyzing tool, is compared to a filter bank that demultiplexes a signal. Local group delay (LGD) and channelized instantaneous frequency (CIF) is obtained for each filtered component signal. In presented solution the performance is evaluated using so-called...
-
Multidimensional GIS for satellite imagery analysis
PublikacjaMultidimensional Geographical Information System allows storing, querying and processing of multidimensional query data. It is able to process satellite imagery and provide tools for its analysis. In the article authors present the developed system that analyzes a time series of SENTINEL - 1 mission satellite imagery acquired over the coast of Poland. The algorithm used finds and detects changes in the shape...
-
Controlled grafting of vinylic monomers on polyolefins: a robust mathematical modeling approach
PublikacjaExperimental and mathematical modeling analyses were used for controlling melt free-radical grafting of vinylic monomers on polyolefins and, thereby, reducing the disturbance of undesired cross-linking of polyolefins. Response surface, desirability function, and artificial intelligence methodologies were blended to modeling/optimization of grafting reaction in terms of vinylic monomer content, peroxide initiator concentration,...
-
Smart Decisional DNA Technology to Enhance Industry 4.0 Environment in Conjunction with Conventional Manufacturing
PublikacjaKnowledge-based support has become an indispensable part not only to the traditional manufacturing set-ups but also to the new fast-emerging Industry 4.0 scenario. In this regard, successful research has been performed and extensively reported to develop Decisional DNA based knowledge representation models of engineering object and engineering process called Virtual engineering object (VEO), Virtual engineering process (VEP) and...
-
Windowing of the Discrete Green's Function for Accurate FDTD Computations
PublikacjaThe paper presents systematic evaluation of the applicability of parametric and nonparametric window functions for truncation of the discrete Green's function (DGF). This function is directly derived from the FDTD update equations, thus the FDTD method and its integral discrete formulation can be perfectly coupled using DGF. Unfortunately, the DGF computations require processor time, hence DGF has to be truncated with appropriate...
-
Noise sources in Raman spectroscopy of biological objects
PublikacjaWe present an overview of noise sources deteriorating the quality of the recorded biological Raman spectra and the ability to determine the specimen composition. The acquired Raman spectra exhibit intense additive noise components or drifts because of low intensity of the scattered light. Therefore we have to apply expensive or bulky measurement setups to limit their inherent noise or to apply additional signal processing to reduce...
-
A quasi-2D small-signal MOSFET model - main results
PublikacjaDynamic properties of the MOS transistor under small-signal excitation are determined by kinetic parameters of the carriers injected into the channel, i.e., the low-field mobility, velocity saturation, mobility at the quiescent-point (Q-point), longitudinal electric field in the channel, by dynamic properties of the channel, as well as by an electrical coupling between the perturbed carrier concentration in the channel and the...
-
Neural network based algorithm for hand gesture detection in a low-cost microprocessor applications
PublikacjaIn this paper the simple architecture of neural network for hand gesture classification was presented. The network classifies the previously calculated parameters of EMG signals. The main goal of this project was to develop simple solution that is not computationally complex and can be implemented on microprocessors in low-cost 3D printed prosthetic arms. As the part of conducted research the data set EMG signals corresponding...
-
Self-optimizing narrowband interference canceller - can reference signal help?
PublikacjaSONIC (Self-Optimizing Narrowband Interference Canceller) is an acronym of the recently proposed active noise control algorithm with interesting adaptivity and robustness properties. SONIC is a purely feedback controller, capable of rejecting nonstationary sinusoidal disturbances (with time-varying amplitudes and/or frequencies) in the presence of plant (secondary path) uncertainties. We show that even though SONIC can work reliably...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 140 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 160 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 180 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 200 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 210 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 260 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 290 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 170 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 280 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 150 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 230 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 240 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
DEPTH IMAGES FILTERING IN DISTRIBUTED STREAMING
PublikacjaIn this paper we discuss the comparison of point cloud filters focusing on their applicability for streaming optimization. For the filtering stage within a stream pipeline processing we evaluate three filters: Voxel Grid, Pass Through and Statistical Outlier Removal. For the filters we perform series of the tests aiming at evaluation of changes of point cloud size and transmitting frequency (various fps ratio). We propose a distributed...
-
Applications of Raman spectroscopy for detection of selected substances in tissues
PublikacjaThis dissertation explores the applications of Raman spectroscopy for biological tissue analysis. Basics of Raman and surface-enhanced Raman spectroscopy (SERS) are described, along with an analysis of the literature on biodetection and non-invasive blood analysis with emphasis on glucose detection. Instrumentation for Raman measurements is described. The sources of noise and interferences occurring in biological tissue measurements...
-
Impact of optimization of ALS point cloud on classification
PublikacjaAirborne laser scanning (ALS) is one of the LIDAR technologies (Light Detection and Ranging). It provides information about the terrain in form of a point cloud. During measurement is acquired: spatial data (object’s coordinates X, Y, Z) and collateral data such as intensity of reflected signal. The obtained point cloud is typically applied for generating a digital terrain model (DTM) and a digital surface model (DSM). For DTM...
-
Vibration data for 1205 EKTN9 bearings
Dane BadawczeThe data contains measurements of vibration obtained with VIBstand manufactured by EC systems.
-
Position Estimation in Corridors Along the Coupled Mode of Radiating Cables
PublikacjaRadiating cables are mostly used to provide radio communication in tunnels or corridors, but they can also be used to estimate the position of a mobile terminal along the cable. In this paper, a measuring receiver’s position was estimated by measuring the difference in the direct signal’s reception time, which was generated by a transmitter connected to one end of the radiating cable, and the delayed signal retransmitted from another...
-
Atomic Force Microscope data post-processing algorithm for higher harmonics imaging
PublikacjaPrevious works have proved that higher harmonics topography imaging using atomic force microscope (AFM) can significantly enhanced its measurement capabilities. Integrated tools dedicated to most of microscopes allow to visualize the investigated surface only by one selected harmonic. Because of the different characteristics of a sample, scanning tip and the environment, appropriate harmonic selection is time consuming and requires...
-
Selected properties and parameters of radio channel impulse response estimation in ISM 2.4 GHz band
PublikacjaThe article presents experimental research indicating that the impulse response of the communication channel, determined in practice, are not of an universal character, but only represent its approximate value for the frequency on which this measurement was made. Phases for each of the replicas of the measurement signal were determined during the analysis of the received signals in the baseband. Phase changes of individual replicas...
-
Marcin Potrykus dr inż.
OsobyAbsolwent Wydziału Zarządzania i Ekonomii Politechniki Gdańskiej. Od 2008 zatrudniony jako Asystent w Katedrze Finansów na Wydziale Zarządzania i Ekonomii Politechniki Gdańskiej. W 2015 roku obronił (w dyscyplinie ekonomia) rozprawę doktorską zatytułowaną „Inwestycje alternatywne – opłacalność a ryzyko”. Od 2016 zatrudniony jako adiunkt w Katedrze Analizy Ekonomicznej i Finansów na Politechnice Gdańskiej. Jego zainteresowania naukowe...
-
AVHRR Level1CD covering Baltic Sea area year 2001
Dane BadawczeThe dataset contains data derived from recordings of the AVHRR/3 radiometer operating on board the NOAA POES (Polar Orbiting Environmental Satellites) Series - 5th Generation Satellites covering the Baltic Sea area. The satellite data was recorded in the years 2000-2012 directly by the HRPT station installed at the University of Gdańsk. The registration...
-
Portable Raman spectrometer - design rules and applications
PublikacjaRaman spectroscopy has become more popular due to its new prospective field applications in forensic sciences, war against terrorism, environment protection and other field chemical analysis. Raman spectrometers can be miniaturised to portable devices and their price is decreasing due to development of optoelectronics components. Unfortunately, this technology has still numerous limitations that influence their design and limit...
-
Paweł Wysocki dr inż.
OsobyW roku 1995 zdał maturę i ukończył Technikum Elektroniczne w Zespole Szkół Technicznych w Suwałkach. Następnie studiował na kierunku Geodezja i Kartografia w zakresie geodezji i systemów informacji przestrzennej na Uniwersytecie Warmińsko-Mazurskim w Olsztynie, gdzie w 2001 roku obronił dyplom magisterski. Tam też ukończył studia podyplomowe w zakresie szacowania nieruchomości. Od 2001 roku był uczestnikiem dziennych studiów doktoranckich...
-
Modeling and Simulation for Exploring Power/Time Trade-off of Parallel Deep Neural Network Training
PublikacjaIn the paper we tackle bi-objective execution time and power consumption optimization problem concerning execution of parallel applications. We propose using a discrete-event simulation environment for exploring this power/time trade-off in the form of a Pareto front. The solution is verified by a case study based on a real deep neural network training application for automatic speech recognition. A simulation lasting over 2 hours...
-
POSSIBILITY OF IDENTIFICATION OF TECHNICAL CONDITION OF BEARINGS FOR SELF-IGNITION ENGINES BY APPLICATION OF ACOUSTIC EMISSION AS A DIAGNOSTIC SIGNAL
PublikacjaThis paper presents the results of empirical studies where the acoustic emission (AE) method was applied to identify the technical condition of sliding surfaces of main and crank bearings for main diesel engines. The test results indicate that the measurements of the AE parameters allow the technical condition identification for bearings of this type. The results refer to the measurements of the parameters for AE generated in the...