Wyniki wyszukiwania dla: HIGH-VOLTAGE VARISTOR - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: HIGH-VOLTAGE VARISTOR

Wyniki wyszukiwania dla: HIGH-VOLTAGE VARISTOR

  • Medium-Voltage Drives: Challenges and existing technology

    Publikacja
    • H. Abu-Rub
    • S. Bayhan
    • S. Moinoddin
    • M. Malinowski
    • J. Guziński

    - IEEE Power Eelectronics Magazine - Rok 2016

    The article presents an overview of state-of-art solutions, advances, and design and research trends in medium-voltage (MV) drive technologies - and also discusses the challenges and requirements associated with the use of such drives. The choice and deployment of MV drives in industries are associated with numerous requirements related to the front-end converter (grid side) and inverter (machine side). The focus is on solutions...

    Pełny tekst do pobrania w portalu

  • CM Voltage Compensators for Power Electronic Interfaces

    Publikacja
    • R. Smoleński
    • J. Bojarski
    • P. Leżyński
    • A. Kempski
    • J. Łuszcz

    - IEEE Electromagnetic Compatibility Magazine - Rok 2015

    The experimental results presented in the paper have shown that the application of the PEIs might cause EMC related problems, especially in the case of the application of a group of connected converters. The most convenient way to reduce EMI currents and prevent aggregation of EMI currents introduced by a group of converters is through passive compensation of voltage interference sources inside of the single converters. In the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors

    This paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...

    Pełny tekst do pobrania w portalu

  • Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors

    This paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...

    Pełny tekst do pobrania w portalu

  • Multipulse inverter structures with low voltage distortion

    Publikacja

    - Rok 2016

    A novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Control strategies and comparison of the Dynamic Voltage Restorer

    Publikacja

    - Rok 2008

    This paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • AC Motor Voltage and Audible Noise Dataset

    Publikacja

    - Rok 2022

    The dataset titled AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters contains the voltage and sound measurement results recorded in a marine frequency controlled AC drive system. The dataset is part of research focussing on the impact of the ship’s electrical drive systems with frequency converters on vibrations and the level of audible noise on ships. The dataset allows the...

    Pełny tekst do pobrania w portalu

  • Static Series and Shunt-series PE Voltage-quality Controllers

    Publikacja

    - Rok 2007

    As presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The Impact of Micro-Sources on Voltage Distortions in a Power Grid

    Publikacja

    The increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...

    Pełny tekst do pobrania w portalu

  • Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym

    Znanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....

    Pełny tekst do pobrania w portalu

  • Voltage control in a power system with renewable sources of energy

    Publikacja

    - Rok 2019

    Intensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • HIGH TEMPERATURES-HIGH PRESSURES

    Czasopisma

    ISSN: 0018-1544 , eISSN: 1472-3441

  • Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter

    In the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Fractional-order Systems and Synchronous Generator Voltage Regulator

    Publikacja

    - Acta Energetica - Rok 2015

    Modern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using...

    Pełny tekst do pobrania w portalu

  • DC-link voltage balancing in cascaded H-Bridge converters

    In the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...

    Pełny tekst do pobrania w portalu

  • Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention

    Publikacja

    - Rok 2014

    In modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Low harmonic multipulse voltage converters using coupled reactors

    Publikacja

    - Rok 2016

    This paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage Harmonics Measuring Issues in Medium Voltage Systems

    Publikacja

    - Rok 2011

    W rozdziale przedstawiono zagadnienia związane z dokładnością pomiarów zniekształceń harmonicznych napięcia z wykorzystaniem przekładników napięciowych w sieciach średnich napięć.

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Selection of energy storage units by genetic algorithm for mitigating voltage deviations

    Publikacja

    In recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS

    Publikacja

    The paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.

  • Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator

    Publikacja

    - Eksploatacja i Niezawodność - Maintenance and Reliability - Rok 2022

    Due to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...

    Pełny tekst do pobrania w portalu

  • Voltage Source Power Line Conditioner for Applications in Local Supply Systems

    Publikacja

    - Rok 2019

    The paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...

    Pełny tekst do pobrania w portalu

  • Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid

    Publikacja

    Current low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...

    Pełny tekst do pobrania w portalu

  • Modular multipulse voltage source inverters with integrating coupled reactors

    Publikacja

    - Rok 2016

    A novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.

    Publikacja

    In this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...

    Pełny tekst do pobrania w portalu

  • Dynamic variables limitation for backstepping control of induction machine and voltage source converter

    Dynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...

    Pełny tekst do pobrania w portalu

  • Design of synchronous generator voltage regulator based on h control theory

    Publikacja

    - Rok 2005

    The power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...

  • Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices

    Publikacja

    - Rok 2016

    A periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...

  • Use of AMI Meters in the Process of Low Voltage Grid Optimization

    Publikacja

    - Acta Energetica - Rok 2017

    This is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .

    Pełny tekst do pobrania w portalu

  • Influence of High Temperature Oxidation on Hydrogen Absorption and Degradation of Zircaloy-2 and Zr 700 Alloys

    The present research was aimed at determining the effects of the oxide layers on hydrogen absorption, microstructure and mechanical properties of the Zircaloy- 2 and Zr 702 alloys. The oxidation was made at 350 °C, 700 °C and 900 °C for 10 to 30 min in laboratory air, followed by hydrogen cathodic charging for 72 h and annealing at 400 °C for 4 h. The slow strain rate tests were carried out on oxidized, charged and annealed specimens. The...

    Pełny tekst do pobrania w portalu

  • Simulation of influence of the air gap asymmetryon voltage waveforms of a synchronous machine

    Publikacja

    - Rok 2005

    Results of simulation of a synchronous generator with the air gap asymmetry characterised by eccentricity are presented in the paper. The Lagrange's energy method has been used in derivation of the model equations. Analysis of influence of the air gap asymmetry on characteristics of self and mutual inductances of windings, as well as analysis of induced voltage waveforms as a function of the air gap asymmetry have been performed....

  • Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter

    Publikacja

    A new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives

    Publikacja

    - Rok 2005

    This paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • HIGH TEMPERATURE

    Czasopisma

    ISSN: 0018-151X , eISSN: 1608-3156

  • High-Throughput

    Czasopisma

    ISSN: 2571-5135

  • Exact generation of voltage vector in voltage inverter with pulse width modulation

    W artykule zaproponowano metodę modulacji szerokości impulsów dla falownika napięcia. Proponowana metoda rozwiązuje problemy związane z kompensacją czasów martwych oraz kompensacją wpływu parametrów łączników energolelektronicznych na napięcie wjściowe falownika. W artykule zaprezentowano metodę kompensacji między innymi pojemności pasożytniczych tranzystorów, dyskretyzacji czasów załączeń tranzystorów. Przedstawiona metoda modulacji...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • High Energy Quality of Buildings 2022/23

    Kursy Online
    • J. Kabrońska

  • High Energy Quality of Buildings 2023/24

    Kursy Online
    • J. Kabrońska

  • Sensorless induction motor drive with voltage inverter and sine-wave filter

    Publikacja

    - Rok 2013

    This paper presents a speed sensorless control system of an induction motor with an output LC filter. It is known that the parameters design of the filter gives sine wave motor supply voltage but complicates control and estimation process. The reason is that the voltage drop and phase shift between filter input and output signals are imposed, and hence the motor voltages and currents differ from the inverter output waveforms. To...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station

    Publikacja

    This paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...

    Pełny tekst do pobrania w portalu

  • Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors

    Publikacja

    - Metrology and Measurement Systems - Rok 2017

    This paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...

    Pełny tekst do pobrania w portalu

  • Wybrane metody diagnostyki łożysk silników indukcyjnych oparte o pomiar prądu

    W artykule zawarto przegląd wybranych metod diagnostyki łożysk silnika indukcyjnego, bazujących na pomiarach prądu zasilającego. Jedno z nowych rozwiązań przetwarzania sygnałów zostało zaadaptowane przez autorów do stosowanego przez nich systemu diagnostycznego. Wyniki wstępnych badań symulacyjnych zweryfikowanych badaniami na rzeczywistym obiekcie wskazują, że rozwiązanie to ułatwia diagnozowanie. Autorzy zamierzają prowadzić...

  • Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response

    Publikacja

    - ENERGIES - Rok 2023

    In this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...

    Pełny tekst do pobrania w portalu

  • Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection

    This paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter

    Publikacja

    - MEASUREMENT - Rok 2023

    The paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • A new approach to cross-bonding in medium voltage cable lines

    Publikacja

    The medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...

    Pełny tekst do pobrania w portalu

  • High Performance Control of AC Drives with Matlab/ Simulink

    Publikacja

    - Rok 2021

    Explore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Robert Bogdanowicz dr hab. inż.

    Robert Bogdanowicz received his Ph.D. degree with honours in Electronics from the Gdansk University of Technology. He worked as a post-doc researcher in Ernst-Moritz-Arndt-Universität Greifswald Institut für Physik. He has initiated optical emission imaging of muti-magnetron pulsed plasma and contributed to the development of antibacterial implant coatings deposited by high-power impulse magnetron sputtering. He moved back to...

  • Synteza bezczujnikowego sterowania maszyną indukcyjną klatkową zasilaną z falownika prądu

    Publikacja

    - Rok 2016

    Synteza bezczujnikowego sterowania maszyną indukcyjną klatkową zasilaną z falownika prądu stanowi cel niniejszej monografii. Praca zawiera podstawowe informacje na temat modelowania układu napędowego z maszyną indukcyjną klatkową zasilaną z falownika prądu. Przedstawiono informacje na temat linearyzacji nieliniowych obiektów. Na pod-stawie metody syntezy strukturalnej opracowano nowe transformacje do postaci zmien-nych multiskalarnych,...

  • Electrical safety in low-voltage DC microgrids with B-type residual current devices

    Publikacja

    Residual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...

    Pełny tekst do pobrania w portalu