Filtry
wszystkich: 7539
-
Katalog
- Publikacje 5273 wyników po odfiltrowaniu
- Czasopisma 47 wyników po odfiltrowaniu
- Konferencje 24 wyników po odfiltrowaniu
- Osoby 80 wyników po odfiltrowaniu
- Projekty 7 wyników po odfiltrowaniu
- Kursy Online 28 wyników po odfiltrowaniu
- Wydarzenia 3 wyników po odfiltrowaniu
- Dane Badawcze 2077 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: HIGH-VOLTAGE VARISTOR
-
Supercapacitors - charge redistribution and restoring voltage
PublikacjaThe charge in supercapacitor is stored on electrodes and in electrolyte. The charges on electrodes create the Helmholtz double layer which is formed immediately with time constant of the order of seconds, while the charge storage in electrolyte is going on with time constant of the order of hundreds seconds. When the charged supercapacitor is shorted for few seconds, the charge from electrodes is discharged while the charge in...
-
Medium-Voltage Drives: Challenges and existing technology
PublikacjaThe article presents an overview of state-of-art solutions, advances, and design and research trends in medium-voltage (MV) drive technologies - and also discusses the challenges and requirements associated with the use of such drives. The choice and deployment of MV drives in industries are associated with numerous requirements related to the front-end converter (grid side) and inverter (machine side). The focus is on solutions...
-
Estimation of the uncertainty of the AC/AC transducer output voltage
PublikacjaThe paper presents a methodology for estimating uncertainty of voltage transducers processing function, on the example of CYVS411D07 voltage transducers. The analysis was conducted using the method based on the GUM Guide propagation of uncertainty law and the determination of the coverage factor based on the effective number of degrees of freedom (t-Student distribution). The paper also presents example evaluation results of measured...
-
CM Voltage Compensators for Power Electronic Interfaces
PublikacjaThe experimental results presented in the paper have shown that the application of the PEIs might cause EMC related problems, especially in the case of the application of a group of connected converters. The most convenient way to reduce EMI currents and prevent aggregation of EMI currents introduced by a group of converters is through passive compensation of voltage interference sources inside of the single converters. In the...
-
Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors
PublikacjaThis paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublikacjaThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Multipulse inverter structures with low voltage distortion
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Control strategies and comparison of the Dynamic Voltage Restorer
PublikacjaThis paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...
-
AC Motor Voltage and Audible Noise Dataset
PublikacjaThe dataset titled AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters contains the voltage and sound measurement results recorded in a marine frequency controlled AC drive system. The dataset is part of research focussing on the impact of the ship’s electrical drive systems with frequency converters on vibrations and the level of audible noise on ships. The dataset allows the...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublikacjaAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublikacjaZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublikacjaThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Voltage control in a power system with renewable sources of energy
PublikacjaIntensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...
-
HIGH TEMPERATURES-HIGH PRESSURES
Czasopisma -
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublikacjaIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
Fractional-order Systems and Synchronous Generator Voltage Regulator
PublikacjaModern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using...
-
DC-link voltage balancing in cascaded H-Bridge converters
PublikacjaIn the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...
-
Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention
PublikacjaIn modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...
-
Low harmonic multipulse voltage converters using coupled reactors
PublikacjaThis paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...
-
Voltage Harmonics Measuring Issues in Medium Voltage Systems
PublikacjaW rozdziale przedstawiono zagadnienia związane z dokładnością pomiarów zniekształceń harmonicznych napięcia z wykorzystaniem przekładników napięciowych w sieciach średnich napięć.
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublikacjaIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS
PublikacjaThe paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublikacjaThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublikacjaCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator
PublikacjaDue to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...
-
Modular multipulse voltage source inverters with integrating coupled reactors
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...
-
Robert Bogdanowicz dr hab. inż.
OsobyRobert Bogdanowicz received his Ph.D. degree with honours in Electronics from the Gdansk University of Technology. He worked as a post-doc researcher in Ernst-Moritz-Arndt-Universität Greifswald Institut für Physik. He has initiated optical emission imaging of muti-magnetron pulsed plasma and contributed to the development of antibacterial implant coatings deposited by high-power impulse magnetron sputtering. He moved back to...
-
A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.
PublikacjaIn this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...
-
Dynamic variables limitation for backstepping control of induction machine and voltage source converter
PublikacjaDynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...
-
Design of synchronous generator voltage regulator based on h control theory
PublikacjaThe power system is highly nonlinear system, which dynamics depends on system network configuration, system loading…etc. To overcome the above mentioned difficulties and to fulfill the performance requirements the different control methods are considered and tested for application to generating control unit. Application of the H optimization method to automatic voltage regulator is studied in this paper. Simulation results have...
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Simulation of influence of the air gap asymmetryon voltage waveforms of a synchronous machine
PublikacjaResults of simulation of a synchronous generator with the air gap asymmetry characterised by eccentricity are presented in the paper. The Lagrange's energy method has been used in derivation of the model equations. Analysis of influence of the air gap asymmetry on characteristics of self and mutual inductances of windings, as well as analysis of induced voltage waveforms as a function of the air gap asymmetry have been performed....
-
Influence of High Temperature Oxidation on Hydrogen Absorption and Degradation of Zircaloy-2 and Zr 700 Alloys
PublikacjaThe present research was aimed at determining the effects of the oxide layers on hydrogen absorption, microstructure and mechanical properties of the Zircaloy- 2 and Zr 702 alloys. The oxidation was made at 350 °C, 700 °C and 900 °C for 10 to 30 min in laboratory air, followed by hydrogen cathodic charging for 72 h and annealing at 400 °C for 4 h. The slow strain rate tests were carried out on oxidized, charged and annealed specimens. The...
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublikacjaA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublikacjaThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Exact generation of voltage vector in voltage inverter with pulse width modulation
PublikacjaW artykule zaproponowano metodę modulacji szerokości impulsów dla falownika napięcia. Proponowana metoda rozwiązuje problemy związane z kompensacją czasów martwych oraz kompensacją wpływu parametrów łączników energolelektronicznych na napięcie wjściowe falownika. W artykule zaprezentowano metodę kompensacji między innymi pojemności pasożytniczych tranzystorów, dyskretyzacji czasów załączeń tranzystorów. Przedstawiona metoda modulacji...
-
HIGH TEMPERATURE
Czasopisma -
High-Throughput
Czasopisma -
High Energy Quality of Buildings 2022/23
Kursy Online -
High Energy Quality of Buildings 2023/24
Kursy Online -
High Energy Quality of Buildings 2024/25
Kursy Online -
Sensorless induction motor drive with voltage inverter and sine-wave filter
PublikacjaThis paper presents a speed sensorless control system of an induction motor with an output LC filter. It is known that the parameters design of the filter gives sine wave motor supply voltage but complicates control and estimation process. The reason is that the voltage drop and phase shift between filter input and output signals are imposed, and hence the motor voltages and currents differ from the inverter output waveforms. To...
-
Wybrane metody diagnostyki łożysk silników indukcyjnych oparte o pomiar prądu
PublikacjaW artykule zawarto przegląd wybranych metod diagnostyki łożysk silnika indukcyjnego, bazujących na pomiarach prądu zasilającego. Jedno z nowych rozwiązań przetwarzania sygnałów zostało zaadaptowane przez autorów do stosowanego przez nich systemu diagnostycznego. Wyniki wstępnych badań symulacyjnych zweryfikowanych badaniami na rzeczywistym obiekcie wskazują, że rozwiązanie to ułatwia diagnozowanie. Autorzy zamierzają prowadzić...
-
Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station
PublikacjaThis paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...
-
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
PublikacjaThis paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...
-
Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response
PublikacjaIn this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...
-
Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection
PublikacjaThis paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublikacjaThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
A new approach to cross-bonding in medium voltage cable lines
PublikacjaThe medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...