Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublikacjaHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublikacjaPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Application of 3D graphic software and GIS in visual impact assessment of high-voltage overhead transmission lines
Publikacja -
The Finite Elements Method application to assesment the impact of turbulence generated by wind turbines on their lacation inclose proximity of overhead high voltage power transmissionlines
PublikacjaThe paper presents selected aspects of construction of wind turbines location concerning aerodynamic impact on power lines. Reaserch is based on the source data concerning the aerodynamic impact of a wind farm consisting of 8 turbines and 400 kV power line, an analysis of the possibility of wind farm locating in the immediate vicinity of the line was carried out. There are serious problems with locating higher capacity wind farms...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Mathematical modelling of the overhead contact line for the purpose of diagnostics of pantographs
PublikacjaThe overhead contact line (OCL) is the most effective way for supplying railway electric vehicles. The increase of the speed of the vehicles increases power consumption and requires ensuring proper cooperation of pantographs with OCL. The paper describes the novel mathematical model of the OCL system and the simulation results. The primary objective is a more accurate analysis to increase the reliability of the evaluation of monitoring...
-
Comparison of thresholding algorithms for automatic overhead line detection procedure
PublikacjaThe article presents an overview of the thresholding algorithms. It compares the algorithms proposed by Pun, Kittler, Niblack, Huang, Rosenfeld, Remesh, Lloyd, Riddler, Otsu, Yanni, Kapur and Jawahar. Additionally, it was tested how the tuning of the Pun, Jawahar and Niblack methods affects the thresholding efficiency and proposed a combination of the Pun algorithm with a priori algorithm. All presented algorithms have been implemented...
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublikacjaThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublikacjaCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublikacjaThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Novel Vision Monitoring Method Based on Multi Light Points for Space-Time Analysis of Overhead Contact Line Displacements
PublikacjaThe article presents an innovative vision monitoring method of overhead contact line (OCL) displacement, which utilizes a set of LED light points installed along it. A light point is an, LED fed from a battery. Displacements of the LED points, recorded by a camera, are interpreted as a change of OCL shape in time and space. The vision system comprises a camera, properly situated with respect to the OCL, which is capable of capturing...
-
Energy losses reduction in the medium voltage cable line – case study
PublikacjaThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublikacjaLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view
PublikacjaPower cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...
-
Marek Olesz dr hab. inż.
OsobyWydział Elektrotechniki i Automatyki, Prodziekan ds. rozwoju dr hab. inż. Marek Olesz, prof. PG data urodzenia 1966 wykształcenie Politechnika Gdańska, Wydział Elektryczny (1990) stopień / tytuł naukowy doktor habilitowany – Politechnika Gdańska, Wydział Elektrotechniki i Automatyki (2017), doktor – Politechnika Gdańska, Wydział Elektrotechniki i Automatyki (1998) zatrudnienie Politechnika Gdańska: asystent stażysta (1989 –...
-
Jarosław Guziński prof. dr hab. inż.
OsobySTOPNIE NAUKOWE 2021 Tytuł profesora nauk inżynieryjno-technicznych. 2012 Stopień doktora habilitowanego nauk technicznych – Wydział Elektrotechniki i Automatyki PG. Rozprawa habilitacyjna „Układy napędowe z silnikami indukcyjnymi i filtrami wyjściowymi falowników. Zagadnienia wybrane”. Kolokwium i nadanie stopnia doktora habilitowanego 29 maja 2012 r. Monografia uzyskała nagrodę naukową Wydziału IV Nauk Technicznych Polskiej...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublikacjaRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
EHV transmission lines wires location on line operation issues - case studies
PublikacjaTransmission lines towers construction affects the line parameters and influences on its operation in the future. Misguided design of the tower can lead to serious problems such as overvoltages, electric arc extinction difficulties, voltage asymmetry, resonance phenomena or increasing of magnetic field near the line. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors....
-
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
PublikacjaThis paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...
-
Nowa metoda obliczania rozpływu prądów zwarciowych w przewodach odgromowych linii wysokiego napięcia
PublikacjaReferat przedstawia nowatorską metodę obliczania wartości prądów płynących w przewodach odgromowych w czasie zwarć, pozwalającą na dobór przewodów odgromowych pod względem wytrzymałości cieplnej. Proponowana metoda charakteryzuje się większą dokładnością i większą uniwersalnością niż powszechnie stosowane metody, pozwalając tym samym na dobór przewodów odgromowych z mniejszym ryzykiem niepewności. Prezentowana metoda obliczeniowa...
-
Efficient Analysis of Noise Induced in Low-Voltage Installations Placed Inside Buildings with Lightning Protection Systems
PublikacjaThis paper describes an efficient approach to the broadband analysis of lightning protection systems (LPSs) using the method of moments (MoM) implemented in the frequency domain. The adaptive frequency sampling (AFS) algorithm, based on a rational interpolation of the relevant observable (e.g., voltage, current, electric or magnetic field) which describes the properties of the LPS, is employed to reduce the number of samples computed...
-
Modelling of MV and HV Cable Lines
PublikacjaOverhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....
-
Analysis of energy efficiency of suburban railway transport network
PublikacjaRising numbers of agglomeration residents cause increased need for people movement on daily basis. Because of congestion of local roads, air pollution and limited parking space, providing mass transit based on electric traction is reasonable. While the electric rail vehicles are considered highly efficient in themselves, they need to be analyzed as a part of a transport network, because energy consumption depends on operating conditions...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublikacjaW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Wielopoziomowy przekształtnik trakcyjny SiC z izolacją od sieci 3kV DC realizowaną za pomocą transformatorów 30kHz do napędów EZT
PublikacjaW referacie przedstawiono wielopoziomowy izolowany kaskadowy przekształtnik DC-AC z tranzystorami SiC MOSFET 1,2kV, przeznaczony do napędów elektrycznych zespołów trakcyjnych (EZT). Zaproponowana konstrukcja przekształtnika, przeznaczonego do pracy przy zasilaniu z sieci trakcyjnej 3kV DC, spełnia założenia energoelektronicznego transformatora trakcyjnego (z ang. Power Electronic Traction Transformer). Budowa modułowa z niskonapięciowych...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublikacjaThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Rozpoznawanie oraz lokalizacja w obrazie przewodów linii wysokiego napięcia
PublikacjaW pracy przedstawiono opracowany algorytm rozpoznawania oraz lokalizacji przewodów linii wysokiego napięcia na podstawie obrazu horyzontalnego. Procedura detekcji przewodu została podzielona na trzy etapy. Pierwszy etap zawiera algorytm wykrywania krawędzi wykazujący największą czułość na krawędzie poziome, a jednocześnie brak czułości na krawędzie pionowe. Efektem jest znaczna redukcja liczby wykrytych krawędzi w porównaniu do...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublikacjaThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
Classification of high-voltage varistors into groups of differentiated quality
PublikacjaThe research was aimed on defining a factor of quality for high-voltage varistors using Non-Destructive Testing (NDT) techniques, which could be applied during the production testing. The newly proposed parameter Q determined on the basis of the lowest resonant frequency fr measured within the preselected frequency range was taken into account. The parameter Q was defined for ZnO structures after firing, without metallized contacts....
-
Resonant ultrasonic spectroscopy in high-voltage varistor spectroscopy
PublikacjaResonant spectroscopy is an effective non-destructive testing method focused on defects in tested objects. The testing procedure, based on the resonant pattern, allows rejection of the tested samples with defects which do not fit the pattern. A sweeping frequency method has been used to measure the spectrum of resonances in high-voltage varistors. As a result we can observe resonances that depend directly on inhomogeneity of the...
-
Quality assessment of high voltage varistors by third harmonic index
PublikacjaHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublikacjaThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublikacjaZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....
-
Gaoya Dianqi/High Voltage Apparatus
Czasopisma -
Gaodianya Jishu/High Voltage Engineering
Czasopisma -
The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables
PublikacjaThis paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled...
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublikacjaThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublikacjaLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
High voltage protective assembly.
PublikacjaW referacie opisano zestaw zabezpieczeniowy, składający się z bezpiecznika i ogranicznika przepięć, przeznaczony dla napowietrznych słupowych stacji transformatorowych średnich napięć. Zastosowany warystorowy ogranicznik przepięć spełnia jednocześnie rolę wspornika dla bezpiecznika gazowydmuchowego. W referacie przedstawiono budowę, podstawowe parametry, przykłady zastosowania oraz wyniki badań zwarciowych zestawu.
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublikacjaResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublikacjaThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublikacjaThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...